A THEORETICAL AND EXPERIMENTAL STUDY OF DIRECT-CONTACT CONDENSATION ON WATER IN TURBULENT FLOW

被引:0
|
作者
Celata, G. P. [1 ]
Cumo, M. [1 ]
D'Annibale, F. [1 ]
Farello, G. E. [1 ]
Focardi, G. [1 ]
机构
[1] ENEA CRE Casaccia TERM ISP Heat Transfer Lab, I-00060 Rome, Italy
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The interaction between saturated or superheated steam in quasi-stagnant conditions and subcooled water in horizontal flow within a rectangular-duct test section has been experimentally investigated and the results are presented. A comparison between experimental results and predictions obtained using available correlations showed their inadequacy for a full description of the phenomenon. A laminar-turbulent mathematical model has been developed for the macroscopic description of the phenomenon and tested with the experimental data. The agreement is acceptable and well within the uncertainty band of the experimental measurements.
引用
收藏
页码:129 / 148
页数:20
相关论文
共 50 条
  • [1] EXPERIMENTAL AND ANALYTICAL STUDY OF DIRECT-CONTACT CONDENSATION OF STEAM IN WATER
    LIANG, KS
    GRIFFITH, P
    NUCLEAR ENGINEERING AND DESIGN, 1994, 147 (03) : 425 - 435
  • [2] A theoretical and experimental investigation of direct-contact condensation on a liquid layer
    Inst Fluid Flow Machinery, Polish Academy of Sciences, PL-80-952 Gdansk, Poland
    Exper Therm Fluid Sci, 3 (221-227):
  • [3] A theoretical and experimental investigation of direct-contact condensation on a liquid layer
    Mikielewicz, J
    Trela, M
    Ihnatowicz, E
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1997, 15 (03) : 221 - 227
  • [4] Numerical study on direct-contact condensation of vapor in cold water
    Takase, K
    Ose, Y
    Kunugi, T
    FUSION ENGINEERING AND DESIGN, 2002, 63-64 : 421 - 428
  • [5] Direct Contact Condensers: A Comprehensive Review of Experimental and Numerical Investigations on Direct-Contact Condensation
    PawelMadejski
    Kus, Tomasz
    Michalak, Piotr
    Karch, Michal
    Subramanian, Navaneethan
    ENERGIES, 2022, 15 (24)
  • [6] Study of steam-water direct-contact condensation in steam jet pump
    Shah A.
    International Journal of Fluid Mechanics Research, 2017, 44 (06) : 487 - 497
  • [7] Experimental investigation on direct-contact condensation of subatmospheric pressure steam in cocurrent flow packed tower
    Chen, Xiqing
    Tian, Zuoxu
    Guo, Feng
    Yu, Xufeng
    Huang, Qunwu
    ENERGY SCIENCE & ENGINEERING, 2022, 10 (08) : 2954 - 2969
  • [8] EXPERIMENTAL STUDY ON CHUGGING CONDENSATION REGIME OF STEAM DIRECT CONTACT CONDENSATION IN WATER FLOW IN A TEE JUNCTION
    Jie, Wang
    Tao, Lu
    Bo, Liu
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 6, 2017,
  • [9] SIMPLE THEORETICAL APPROACH TO DIRECT-CONTACT CONDENSATION ON SUBCOOLED LIQUID-FILM
    MIKIELEWICZ, J
    RAGEB, AMA
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1995, 38 (03) : 557 - 562
  • [10] Theoretical and experimental study of volumetric heat transfer coefficient for Direct-Contact Heat Exchanger
    Huang, Junwei
    Wang, Shibo
    Hu, Jianhang
    ADVANCES IN ENERGY, ENVIRONMENT AND MATERIALS SCIENCE, 2016, : 367 - 373