OPERATIVE LUNG CONSTANT POSITIVE AIRWAY PRESSURE WITH THE UNIVENT BRONCHIAL BLOCKER TUBE

被引:0
|
作者
BENUMOF, JL [1 ]
GAUGHAN, S [1 ]
OZAKI, GT [1 ]
机构
[1] FUJI SYST CORP,TOKYO,JAPAN
来源
ANESTHESIA AND ANALGESIA | 1992年 / 74卷 / 03期
关键词
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Constant positive airway pressure (CPAP) to the operative lung during one-lung ventilation (1-LV) with a double-lumen tube increases PaO2; there have been no reports of application of CPAP to the operative lung during 1-LV with the Univent bronchial blocker (BB) tube. This study determined the method of administration and the effect on PaO2 of 10 cm H2O of CPAP to the operative lung during 1-LV (1-LV + 10 CPAP) produced by the Univent BB system. We designed our CPAP system for the Univent BB using an in vitro lung model so that low O2 flow rates (2-4 L/min) yield clinically relevant levels of CPAP (5-20 cm H2O) over a wide range of lung compliance. The CPAP system simply consisted of placing a resistance to a variable oxygen flow distal to the operative lung. Seven consenting patients who required thoracotomy and 1-LV were anesthetized and their tracheas were intubated with the Univent BB tube; the BB was inserted into the appropriate mainstem bronchus until the proximal surface of the BB cuff was just distal to the tracheal carina. PaO2 was measured in the seven patients during 12 sequences of two-lung ventilation (2-LV), one-lung ventilation (1-LV), and 1-LV with 10 cm H2O CPAP (1-LV + 10 CPAP). 1-LV + 10 CPAP was always instituted on the deflation phase of a previous single tidal inhalation. We found in our patients with a lung compliance of 32 +/- 4 mL/cm H2O that 2.4 +/- 0.2 L/min of oxygen flow produced 1-LV + 10 CPAP. The mean +/- SD PaO2 during 2-LV, 1-LV, and 1-LV + 10 CPAP was 347 +/- 159, 127 +/- 93, and 312 +/- 122 mm Hg, respectively. The PaO2 during 1-LV was significantly decreased compared with both 2-LV and 1-LV + 10 CPAP (both P < 0.001), and there was no significant difference in PaO2 during 2-LV compared with 1-LV + 10 CPAP (P > 0.2). One-lung ventilation + 10 CPAP did not have any statistically significant hemodynamic effect or interfere with surgical exposure. We conclude that 1-LV + 10 CPAP through the Univent BB tube is technically simple to administer and is potentially an efficacious treatment of hypoxemia during 1-LV.
引用
收藏
页码:406 / 410
页数:5
相关论文
共 50 条
  • [31] Hypoxemia Treatment During Lung Isolation With an Endobronchial Blocker: Continuous Positive Airway Pressure Application Should Be Common Practice
    Pineda, Pedro
    Awad, Hamdy
    Essandoh, Michael K.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (07) : 2104 - 2105
  • [32] Independent placement of a bronchial blocker for single-lung ventilation: An alternative method for the difficult airway
    Harvey, SC
    Alpert, CC
    Fishman, RL
    ANESTHESIA AND ANALGESIA, 1996, 83 (06): : 1330 - 1331
  • [33] Collapsed lung isolates in two steps using a bronchial blocker: equivalent to a double light tube?
    Bussieres, J. S.
    del Castillo, J. L. Carrasco
    Lemieux, J.
    Somma, J.
    Conti, M.
    Gagne, N.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 : A403 - A403
  • [34] Comparison of double-lumen tube and bronchial blocker on one-lung ventilation for thoracoscopy
    Bauer, C
    Esclope, C
    Hentz, JG
    Ducrocq, X
    Steib, A
    Dupeyron, JP
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 : 26 - 26
  • [35] Successful Use of a Double Lumen Endotracheal Tube and Bronchial Blocker for Lung Isolation in Pulmonary Mucormycosis
    Wanat-Hawthorne, Alycia
    Stubblefield, Jonathan
    Lynch, Isaac
    Dellaria, Suzanne
    Kernstine, Kemp
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (03) : 776 - 780
  • [36] INFLUENCE OF CONSTANT SUSTAINED POSITIVE AIRWAY PRESSURE ON RIGHT VENTRICULAR PERFORMANCE
    IMAI, T
    UCHIYAMA, M
    MARUYAMA, N
    YOSHIKAWA, D
    FUJITA, T
    INTENSIVE CARE MEDICINE, 1993, 19 (01) : 8 - 12
  • [37] Constant positive airway pressure reduces hypoventilation induced by inhalation anesthesia
    Smith, RA
    Bratzke, EC
    Miguel, RV
    JOURNAL OF CLINICAL ANESTHESIA, 2005, 17 (01) : 44 - 50
  • [38] Single-Lumen Endotracheal Tube and Bronchial Blocker for Airway Management During Tracheobronchoplasty for Tracheobronchomalacia: A Case Report
    Lui, Natalie S.
    Guo, Haiwei Henry
    Sung, Arthur W.
    Peterson, Ashley
    Kulkarni, Vivekanand N.
    A & A PRACTICE, 2019, 13 (06): : 236 - 239
  • [39] A Solution to the Jones Tube Continuous Positive Airway Pressure (CPAP) Dilemma?
    Servat, J. Javier
    Black, Evan H.
    Gladstone, Geoffrey J.
    OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2012, 28 (06): : E151 - E152
  • [40] Sleep apnea is associated with bronchial inflammation and continuous positive airway pressure-induced airway hyperresponsiveness
    Devouassoux, Gilles
    Levy, Patrick
    Rossini, Eliane
    Pin, Isabelle
    Fior-Gozlan, Michele
    Henry, Mireille
    Seigneurin, Daniel
    Pepin, Jean-Louis
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2007, 119 (03) : 597 - 603