QUANTITATIVE-ANALYSIS OF EXTRACELLULAR-SUPEROXIDE DISMUTASE IN SERUM AND URINE BY ELISA WITH MONOCLONAL-ANTIBODY

被引:87
|
作者
ADACHI, T
OHTA, H
YAMADA, H
FUTENMA, A
KATO, K
HIRANO, K
机构
[1] GIFU PHARMACEUT UNIV, DEPT PHARMACEUT, 5-6-1 MITAHORA HIGASHI, GIFU 502, JAPAN
[2] AICHI MED UNIV, DEPT INTERNAL MED 1, AICHI, JAPAN
关键词
EXTRACELLULAR-SUPEROXIDE DISMUTASE; MONOCLONAL ANTIBODY; ENZYME-LINKED IMMUNOSORBENT ASSAY;
D O I
10.1016/0009-8981(92)90176-Q
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The superoxide anion has been implicated in a wide range of diseases. The major protector against superoxide anion in the extracellular space is extracellular-superoxide dismutase (EC-SOD). EC-SOD is the major SOD isozyme in plasma and forms an equilibrium between the plasma phase and heparan sulfate proteoglycan on the surface of the endothelium. An ELISA method for the measurement of human EC-SOD with monoclonal antibody was established. The proposed method had a high sensitivity (assay range, 0.05-50 ng/ml), good recovery (recovery percentage, 96.9 +/- 5.6%) and reproducibility (within-day assay, C.V. = 8.6 approximately 10.2%; between-day assay, C.V. = 6.5 approximately 11.7%). EC-SOD levels in sera from healthy persons are clearly divided into two groups: a lower group (Group I, below 120 ng/ml, n = 146) and higher group (Group II, above 400 ng/ml, n = 10). The EC-SOD in Group I were almost normally distributed and the mean level was 55.8 +/- 18.8 ng/ml. The serum EC-SOD level assayed by ELISA correlated well with serum SOD activity. The serum EC-SOD in Group I is heterogeneous with regard to affinity for heparin-Sepharose and could be separated into three approximately equal fractions, whereas the EC-SOD in Group II is mainly one fraction with a high affinity for the column. The apparent molecular weight and carbohydrate structure of serum EC SOD in Group II are identical to those in Group I. The high EC-SOD level in sera from some individuals may reflect the excessive stimulation of EC-SOD synthesis in vivo or the growth of selected cells in vivo, because EC-SOD is known to be expressed by a few cell types in vivo as a high-heparin-affinity subtype.
引用
收藏
页码:89 / 102
页数:14
相关论文
共 50 条
  • [41] QUANTITATIVE-ANALYSIS OF SPERMATOGENIC DNA-SYNTHESIS IN THE RAT USING A MONOCLONAL ANTI-5-BROMODEOXYURIDINE ANTIBODY
    SHIRATAKI, S
    TAKIHARA, H
    IMOTO, K
    KAMADA, K
    BABA, Y
    NAITO, K
    ANDROLOGIA, 1994, 26 (06) : 343 - 349
  • [42] QUANTITATIVE-ANALYSIS OF MONOCLONAL ANTIBODY-DEFINED HUMAN-MELANOMA ANTIGENS USING FLOW-CYTOMETRY
    BERTELSEN, CA
    WELLS, JR
    SAXTON, RE
    BURK, MW
    PROCEEDINGS OF THE AMERICAN ASSOCIATION FOR CANCER RESEARCH, 1983, 24 (MAR): : 234 - 234
  • [43] AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY (ELISA) FOR ADENOSINE 3',5'-CYCLIC-MONOPHOSPHATE (CAMP) IN HUMAN PLASMA AND URINE USING MONOCLONAL-ANTIBODY
    TSUGAWA, M
    IIDA, S
    FUJII, H
    MORIWAKI, K
    TARUI, S
    JOURNAL OF IMMUNOASSAY, 1990, 11 (01): : 49 - 61
  • [44] EXTRACELLULAR-SUPEROXIDE DISMUTASE (SOD3) - TISSUE-SPECIFIC EXPRESSION, GENOMIC CHARACTERIZATION, AND COMPUTER-ASSISTED SEQUENCE-ANALYSIS OF THE HUMAN EC SOD GENE
    FOLZ, RJ
    CRAPO, JD
    GENOMICS, 1994, 22 (01) : 162 - 171
  • [45] SERUM-MANGANESE-SUPEROXIDE DISMUTASE - NORMAL VALUES AND INCREASED LEVELS IN PATIENTS WITH ACUTE MYOCARDIAL-INFARCTION AND SEVERAL MALIGNANT DISEASES DETERMINED BY AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY USING A MONOCLONAL-ANTIBODY
    KAWAGUCHI, T
    SUZUKI, K
    MATSUDA, Y
    NISHIURA, T
    UDA, T
    ONO, M
    SEKIYA, C
    ISHIKAWA, M
    IINO, S
    ENDO, Y
    TANIGUCHI, N
    JOURNAL OF IMMUNOLOGICAL METHODS, 1990, 127 (02) : 249 - 254
  • [46] Monoclonal antibody against sulfaquinoxaline and quantitative analysis in chicken tissues by competitive indirect ELISA and lateral flow immunoassay
    Ngom, Babacar
    Guo, Yancheng
    Jin, Xiue
    Shi, Deshi
    Zeng, Yong
    Le, Tao
    Lu, Fang
    Wang, Xiliang
    Bi, Dingren
    FOOD AND AGRICULTURAL IMMUNOLOGY, 2011, 22 (01) : 1 - 16
  • [47] QUANTITATION OF FREE-KAPPA-LIGHT CHAINS IN SERUM AND URINE USING A MONOCLONAL-ANTIBODY BASED INHIBITION ENZYME-LINKED IMMUNOASSAY
    AXIAK, SM
    KRISHNAMOORTHY, L
    GUINAN, J
    RAISON, RL
    JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 99 (01) : 141 - 147
  • [48] HUMAN INTERFERON-GAMMA QUANTIFIED VIA A SENSITIVE ONE-SITE MONOCLONAL-ANTIBODY IN A SANDWICH ELISA - A PEG MODIFICATION FOR MEASUREMENT IN SERUM
    BERG, K
    APMIS, 1994, 102 (01) : 13 - 22
  • [49] KINETICS, QUANTITATIVE-ANALYSIS AND IMMUNOLOCALIZATION USING RADIOLABELED HMFG1-MONOCLONAL ANTIBODY IN PATIENTS WITH BREAST-CANCER
    KALOFONOS, HP
    SACKIER, JM
    HATZISTILIANOU, MN
    WOOD, CB
    WAXMAN, JH
    LAVENDER, PJ
    EPENETOS, AA
    BRITISH JOURNAL OF CANCER, 1989, 59 (02) : 318 - 318
  • [50] DIFFERENTIAL ASSAY OF SALIVARY AND PANCREATIC ALPHA-AMYLASE IN SERUM AND URINE, WITH USE OF MONOCLONAL-ANTIBODY TO HUMAN SALIVARY AMYLASE IMMOBILIZED ON BACTERIAL-CELL WALL
    HIROISHI, S
    MATSUYAMA, S
    KUROOKA, S
    SUNAHARA, N
    INOUE, S
    IDA, T
    CLINICAL CHEMISTRY, 1987, 33 (07) : 1235 - 1236