C1-C3 Lateral Mass Screw-Rod Fixation and Fusion for C2 Pathologies and Hangman's Fractures

被引:7
|
作者
Chowdhury, Forhad Hossain [1 ]
Haque, Mohammod Raziul [1 ]
机构
[1] Dhaka Med Coll Hosp, Dept Neurosurg, 32 Bokshibazar Rd, Dhaka, Bangladesh
关键词
C1-C3 lateral mass fixation; Hangman's fracture; C2; pathology;
D O I
10.4184/asj.2014.8.6.735
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Retrospective clinical study. Purpose: We report our experience of eight patients treated with C1-C3 lateral mass rod-screw stabilization and fusion in the treatment of Hangman's fracture and other axis pathologies. Overview of Literature: Different surgical approaches, both anterior and posterior, have been described for treating Hangman's fracture and other pathologies where surgery is indicated. Methods: All patients who underwent surgical treatment for Hangman's fracture and axial pathology where C1-C3 lateral mass screw-rod stabilization and fusion done, following reduction of the fracture or removal of the pathology were included in this series. The recorded patient management data was retrospectively studied. Results: There were 8 cases in total. All were male, with an average age of 40.75 years. Hangman's fracture occurred in 6 cases (75%), one with metastatic squamous cell carcinoma and the remaining with plasmocytoma. Among the Hangman's fractures 4 (66.66%) had no neuro-deficit. Reduction and bilateral C1-C3 lateral mass screw and rod fixation with posterior fusion by bone graft was performed in all cases. In 2 cases, a C2 body tumor was removed transorally. All patients with neuro-deficit fully recovered, except one who expired in the early post-operative period. Rest of all patients were leading a normal life till last follow up. Conclusions: Although the number of cases was very small with a relatively short follow up period, C1 and C3 lateral mass screwrod fixation followed by fusion showed promise as an effective and biomechanically sound way for the treatment of properly selected Hangman's fracture cases, and may also be suitable in other axial pathologies.
引用
收藏
页码:735 / 746
页数:12
相关论文
共 50 条
  • [31] Outcomes of C1 and C2 posterior screw fixation for upper cervical spine fusion
    De Iure, F.
    Donthineni, R.
    Boriani, S.
    EUROPEAN SPINE JOURNAL, 2009, 18 : S2 - +
  • [32] Stabilization of the Atlantoaxial Joint With C1-C3 Lateral Mass Screw Constructs: Biomechanical Comparison With Standard Technique
    Brasiliense, Leonardo B. C.
    Lazaro, Bruno C. R.
    Reyes, Phillip M.
    Fox, Douglas
    Sonntag, Volker K. H.
    Crawford, Neil R.
    NEUROSURGERY, 2010, 67 : ons422 - ons427
  • [33] Biomechanical study of novel unilateral C1 posterior arch screws and C2 laminar screws combined with an ipsilateral crossed C1-C2 pedicle screw-rod fixation for atlantoaxial instability
    Shen, Kai
    Deng, Zhongliang
    Yang, Junsong
    Liu, Chao
    Zhang, Ranxi
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (10) : 1349 - 1355
  • [34] Lateral mass screw fixation of C-1: Response
    Jea, Andrew
    Drake, James M.
    Rutka, James T.
    Taylor, Michael D.
    Dirks, Peter B.
    Kulkarni, Abhaya V.
    JOURNAL OF NEUROSURGERY, 2007, 107 (02) : 174 - 177
  • [35] The Comparison Between Transarticular Screw Fixation and Segmental Screw-Rod Fixation for Posterior Fusion of the C1-2 Segment: A Systematic Review and Meta-Analysis
    Chang, Min Cheol
    Seok, Hyun-Gyu
    Choo, Yoo Jin
    Lee, Gun Woo
    WORLD NEUROSURGERY, 2022, 164 : E1007 - E1014
  • [36] Radiographic Evaluation of the Technique for C1 Lateral Mass and C2 Pedicle Screw Fixation in Three Hundred Nineteen Cases
    Wang, Shenglin
    Wang, Chao
    Wood, Kirkham B.
    Yan, Ming
    Zhou, Haitao
    SPINE, 2011, 36 (01) : 3 - 8
  • [37] Posterior C1-2 fusion with C1 lateral mass and C2 isthmic screws: accuracy of screw position, alignment and patient outcome
    Florian Ringel
    Andreas Reinke
    Carsten Stüer
    Bernhard Meyer
    Michael Stoffel
    Acta Neurochirurgica, 2012, 154 : 305 - 312
  • [38] Posterior C1-2 fusion with C1 lateral mass and C2 isthmic screws: accuracy of screw position, alignment and patient outcome
    Ringel, Florian
    Reinke, Andreas
    Stueer, Carsten
    Meyer, Bernhard
    Stoffel, Michael
    ACTA NEUROCHIRURGICA, 2012, 154 (02) : 305 - 312
  • [39] C1 Sparing Posterior Fixation with C2 Pedicle Realignment for Hangman Fracture
    Sadhwani, Nidhisha
    Sawant, Ninad
    Gupta, Deepak
    NEUROLOGY INDIA, 2024, 72 (03) : 500 - 502
  • [40] Safety Issues and Neurological Improvement following C1-C2 Fusion using C1 Lateral Mass and C2 Pedicle Screw in Atlantoaxial Instability
    Kwan, M. K.
    Chan, C. Y. W.
    Kwan, T. C. C.
    Gashi, Y. N.
    Saw, L. B.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2010, 4 (02) : 17 - 22