Changes in Day 1 Post-Operative Intraocular Pressure Following Sutureless 23-Gauge and Conventional 20-Gauge Pars Plana Vitrectomy

被引:13
|
作者
Gosse, Emily [1 ]
Newsom, Richard [2 ]
Hall, Peter [3 ]
Lochhead, Jonathan [1 ]
机构
[1] St Marys Hosp, Dept Ophthalmol, Newport PO30 5TG, Shrops, England
[2] Southampton Gen Hosp, Dept Ophthalmol, Southampton, Hants, England
[3] Univ Leeds, Leeds, W Yorkshire, England
来源
OPEN OPHTHALMOLOGY JOURNAL | 2013年 / 7卷
关键词
Transconjunctival sutureless vitrectomy; 23-gauge vitrectomy; post-operative hypotony; post-operative IOP;
D O I
10.2174/1874364101307010042
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/Aims: The benefits associated with transconjunctival sutureless vitrectomy techniques are continuing to be defined. The purpose of this study was to compare the incidence of extreme changes in day 1 intraocular pressure (IOP) following 23-gauge sutureless vitrectomy compared with conventional 20-gauge vitrectomy. Methods: Fifty consecutive 23-gauge and 50 consecutive 20-gauge cases were included; eyes with a history of previous vitreoretinal surgery were excluded. 23-gauge surgery was completed with passive fluid air exchange where no long acting tamponade was indicated. The surgery remained sutureless unless a leak was visible at the end of the procedure. Data were collected by retrospective case note review. Statistical analysis was carried out using Fisher's exact and chisquare tests. Results: Twenty-two percent (11/50) of 23-gauge vitrectomies required suturing of one or more ports. On the first postoperative day hypotony (IOP<5mmHg) occurred in 1/50 eyes in the 20- and 23-gauge groups. Raised pressure (IOP>21mmHg) occurred in 30% (15/50) of eyes in the 20-gauge group and 8% (4/50) of eyes in the 23-gauge group; IOP>30mmHg only occurred in the 20-gauge group (3/50). Conclusion: Fluid air exchange following 23-gauge vitrectomy is associated with very low risk of day 1 hypotony. This predominantly sutureless technique appears to reduce the incidence and magnitude of early post-operative IOP elevation compared with conventional 20-gauge vitrectomy.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [11] Comparison of postoperative ciliary body changes associated with the use of 23-gauge and 20-gauge system for pars plana vitrectomy
    Tang, Meng-su
    Zhang, Shu-qi
    Ma, Li-wei
    BMC OPHTHALMOLOGY, 2018, 18
  • [12] Incidence of endophthalmitis after 20-gauge vs 23-gauge vs 25-gauge pars plana vitrectomy
    Scott, Ingrid U.
    Flynn, Harry W., Jr.
    Acar, Nur
    Dev, Sundeep
    Shaikh, Saad
    Mittra, Robert A.
    Fernando Arevalo, J.
    Kychenthal, Andres
    Kunselman, Allen
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (03) : 377 - 380
  • [13] 23-gauge transconjunctival sutureless vitrectomy in treatment of post-operative endophthalmitis
    Ahmed M. Almanjoumi
    Aurélie Combey
    Jean Paul Romanet
    Christophe Chiquet
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2012, 250 : 1367 - 1371
  • [14] Incidence of endophthalmitis after 20-gauge vs 23-gauge vs 25-gauge pars plana vitrectomy
    Ingrid U. Scott
    Harry W. Flynn
    Nur Acar
    Sundeep Dev
    Saad Shaikh
    Robert A. Mittra
    J. Fernando Arevalo
    Andres Kychenthal
    Allen Kunselman
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 377 - 380
  • [15] 23-gauge transconjunctival sutureless vitrectomy in treatment of post-operative endophthalmitis
    Almanjoumi, Ahmed M.
    Combey, Aurelie
    Romanet, Jean Paul
    Chiquet, Christophe
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2012, 250 (09) : 1367 - 1371
  • [16] Early Postoperative Intraocular Pressure After 23-Gauge Sutureless Small-Incision Pars Plana Vitrectomy
    Schadlu, Ramin
    Shah, Gaurav K.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (07): : 1043 - 1044
  • [17] Combined 20-and 23-gauge pars plana vitrectomy
    Totan, Yuksel
    Guler, Emre
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2015, 78 (04) : 265 - 266
  • [18] Combined 20-gauge and 23-gauge pars plana vitrectomy for the management of posteriorly dislocated lens: a case series
    Kongsap, Pipat
    CLINICAL OPHTHALMOLOGY, 2010, 4 : 625 - 628
  • [19] Intraoperative iatrogenic peripheral retinal break in 23-gauge transconjunctival sutureless vitrectomy versus 20-gauge conventional vitrectomy
    Cha, Dong Min
    Woo, Se Joon
    Park, Kyu Hyung
    Chung, Hum
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (06) : 1469 - 1474
  • [20] Intraoperative iatrogenic peripheral retinal break in 23-gauge transconjunctival sutureless vitrectomy versus 20-gauge conventional vitrectomy
    Dong Min Cha
    Se Joon Woo
    Kyu Hyung Park
    Hum Chung
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 1469 - 1474