C-13 BICARBONATE BREATH TEST AS A MEASURE OF GASTRIC-EMPTYING

被引:0
|
作者
BJORKMAN, DJ
MOORE, JG
KLEIN, PD
GRAHAM, DY
机构
[1] VET ADM MED CTR,GASTROENTEROL,SALT LAKE CITY,UT
[2] BAYLOR UNIV,DEPT MED,HOUSTON,TX 77030
[3] BAYLOR UNIV,USDA ARS,CHILDRENS NUTR RES CTR,DEPT PEDIAT,HOUSTON,TX 77030
[4] VET ADM MED CTR,DEPT GASTROENTEROL,HOUSTON,TX 77211
来源
AMERICAN JOURNAL OF GASTROENTEROLOGY | 1991年 / 86卷 / 07期
关键词
D O I
暂无
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Radionuclide studies are widely used to estimate the gastric emptying rate of solids and liquids. Unfortunately, these methods carry the risk of radiation exposure and require expensive and complex equipment. Carbon-13, a stable, nonradioactive isotope, has been used successfully as a marker in the gastrointestinal tract for other purposes. A preliminary study using ingested NaH13CO3 and measuring 13CO2 breath excretion suggested that this test might be a simple, noninvasive, and inexpensive method for determining gastric emptying. To determine the efficacy of NaH13CO3 as a noninvasive marker for gastric emptying, the resulting 13CO2 breath excretion was determined simultaneously with standard radiolabeled meal measurements of gastric emptying of liquids and solids in 15 patients. 13CO2 breath excretion did not correlate with the gastric emptying of either solids or liquids, as determined by radio-nuclide techniques. These results suggest that NaH13CO3 is not a reliable indicator of gastric emptying. Factors other than gastric emptying may affect the rate of 13CO2 absorption and exhalation, rendering it unreliable as a measure of gastric emptying.
引用
收藏
页码:821 / 823
页数:3
相关论文
共 50 条
  • [21] Standardization of the testmeal for the 13C octanoic acid breath test to measure gastric emptying of solids in children.
    Van Den Driessche, M
    Ghoos, Y
    Veereman-Wauters, G
    GASTROENTEROLOGY, 1998, 114 (04) : A851 - A851
  • [22] 13C octanoic acid breath test:: Valueless test for gastric emptying?: Reply
    Choi, MG
    Camilleri, M
    Zinsmeister, AR
    GASTROENTEROLOGY, 1998, 114 (04) : 858 - 859
  • [23] C-13 BREATH TEST AS EXTENTION OF C-14 BREATH TEST
    SASAKI, Y
    OHHARA, H
    MAEDA, T
    SOMEYA, K
    SANO, M
    JOURNAL OF NUCLEAR MEDICINE, 1976, 17 (06) : 551 - 551
  • [24] MEASURE OF THE GASTRIC-EMPTYING OF LIQUIDS IN THE RAT
    SCARPIGNATO, C
    JOURNAL DE PHARMACOLOGIE, 1983, 14 (02) : 261 - 268
  • [25] Performance characteristics of a [13C]-Spirulina platensis gastric emptying breath test
    Szarka, Lawrence A.
    Camilleri, Michael
    Burton, Duane D.
    Martin, Robert F.
    GASTROENTEROLOGY, 2006, 130 (04) : A510 - A510
  • [26] Measurement of gastric emptying by the 13C-octanoate breath test -: rationalization with scintigraphy
    Bluck, LJC
    Coward, WA
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (03) : 279 - 289
  • [27] Gastric emptying rate in subjects with malocclusion examined by [13C] breath test
    Koike, S.
    Sujino, T.
    Ohmori, H.
    Shimazaki, K.
    Fukuyama, E.
    Kanai, T.
    Hibi, T.
    Ono, T.
    JOURNAL OF ORAL REHABILITATION, 2013, 40 (08) : 574 - 581
  • [28] 13C-octanoic acid breath test to study gastric emptying time
    Bruno, G.
    Lopetuso, L. R.
    Ianiro, G.
    Laterza, L.
    Gerardi, V.
    Petito, V.
    Poscia, A.
    Gasbarrini, A.
    Ojetti, V.
    Scaldaferri, F.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2013, 17 : 59 - 64
  • [29] Use of 13C-Acetate breath test for assessment of gastric emptying in horses
    Sasaki, N
    Aiuchi, H
    Yamada, H
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2005, 67 (10): : 993 - 997
  • [30] 13C-octanoic acid breath test for gastric emptying rate of solids
    Maes, BD
    Geypens, BJ
    Ghoos, YF
    Hiele, MI
    Rutgeerts, RJ
    GASTROENTEROLOGY, 1998, 114 (04) : 856 - 857