DETECTION OF CHANGES IN INTRATHORACIC FLUID IN MAN USING ELECTRICAL-IMPEDANCE TOMOGRAPHY

被引:18
|
作者
CAMPBELL, JH
HARRIS, ND
ZHANG, F
MORICE, AH
BROWN, BH
机构
[1] ROYAL HALLAMSHIRE HOSP,RESP MED SECT,SHEFFIELD S10 2RX,S YORKSHIRE,ENGLAND
[2] ROYAL HALLAMSHIRE HOSP,DEPT MED PHYS & CLIN ENGN,SHEFFIELD S10 2RX,S YORKSHIRE,ENGLAND
关键词
ELECTRICAL IMPEDANCE; PULMONARY BLOOD VOLUME; TOMOGRAPHY;
D O I
10.1042/cs0870097
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
1. The Sheffield electrical impedance tomography system produces information on changes in the distribution of resistivity within tissue. We report on the assessment of electrical impedance tomography in monitoring changes in lung resistivity during a fluid challenge in normal man. 2. Eight normal subjects were studied. Electrical impedance tomography recordings were made at three different lung volumes before, during and after the intravenous infusion of 1 litre of 0.9% NaCl (saline). 3. The mean fall in lung resistivity during the infusion was -22% at total lung capacity (range -10% to -28%), -24% at tidal breathing (-15% to -37%) and -11% at residual volume (-5% to -19%) (P<0.05 mean pre-infusion resistivity compared with the nadir value after infusion, Wilcoxon). 4. These changes in lung resistivity were probably due to a combination of a fall in haematocrit and an expansion of pulmonary blood volume.
引用
收藏
页码:97 / 101
页数:5
相关论文
共 50 条
  • [21] MULTIELECTRODE SYSTEMS FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    MCADAMS, ET
    MCLAUGHLIN, JA
    ANDERSON, JM
    PHYSIOLOGICAL MEASUREMENT, 1994, 15 : A101 - A106
  • [22] A HYBRID PHANTOM FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    PAULSON, K
    BRECKON, W
    PIDCOCK, M
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 155 - 159
  • [23] OPTIMAL EXPERIMENTS IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    PAULSON, K
    LIONHEART, W
    PIDCOCK, M
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1993, 12 (04) : 681 - 686
  • [24] A SENSITIVITY METHOD FOR ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BARBER, DC
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1989, 10 (04): : 368 - 370
  • [25] USE OF ELECTRICAL-IMPEDANCE TO MONITOR CHANGES IN BLOOD-FLOW IN MAN
    ARENSON, HM
    PAYNE, JP
    SMITH, TGC
    JOURNAL OF PHYSIOLOGY-LONDON, 1978, 281 (AUG): : P10 - P11
  • [26] Detection and quantification of intraperitoneal fluid using electrical impedance tomography
    Sadleir, RJ
    Fox, RA
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2001, 48 (04) : 484 - 491
  • [27] MODEL FOR THE CARDIAC-ASSOCIATED CHANGES OF THE THORACIC ELECTRICAL-IMPEDANCE IN MAN
    GIRLING, M
    IMRIE, DC
    PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (01): : 107 - 123
  • [28] BLOOD-FLOW IMAGING USING ELECTRICAL-IMPEDANCE TOMOGRAPHY
    BROWN, BH
    LEATHARD, A
    SINTON, A
    MCARDLE, FJ
    SMITH, RWM
    BARBER, DC
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1992, 13 : 175 - 179
  • [29] TRANS-THORACIC ELECTRICAL-IMPEDANCE AS AN INDEX OF EXTRACELLULAR FLUID VOLUME IN MAN
    ROOS, JC
    KOOMANS, HA
    BOER, P
    MEES, EJD
    INTENSIVE CARE MEDICINE, 1985, 11 (01) : 39 - 42
  • [30] ELECTRICAL-IMPEDANCE MEASURED CHANGES IN THORACIC FLUID CONTENT DURING THORACENTESIS
    PETERSEN, JR
    JENSEN, BV
    DRABAEK, H
    VISKUM, K
    MEHLSEN, J
    CLINICAL PHYSIOLOGY, 1994, 14 (04): : 459 - 466