PRACTICAL GUIDANCE FOR FLUX CHAMBER MEASUREMENTS OF FUGITIVE VOLATILE ORGANIC EMISSION RATES

被引:90
|
作者
EKLUND, B
机构
[1] Radian Corporation, Austin, TX, 78720-1088
来源
关键词
D O I
10.1080/10473289.1992.10467102
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Hazardous waste sites and industrial facilities contain area sources of fugitive emissions. Emission rate measurements or estimates are necessary for air pathway assessments for these sources. Emission rate data can be useful for the design of emission control and remediation strategies as well as for predictive modeling for population exposure assessments. This paper describes the use of a direct emission measurement approach - the enclosure approach using an emission isolation flux chamber - to measure emission rates of various volatile organic compounds (VOCs) from contaminated soil and water. A variety of flux chamber equipment designs and operating procedures have been employed by various researchers. This paper contains a review of the design and operational variables that affect the accuracy and precision of the method. Guidance is given as to the optimum flux chamber design and operating conditions for various types of emission sources. Also presented is a generic quality control program that gives the minimum number of duplicate, blank, background, and repeat samples that should be performed.
引用
收藏
页码:1583 / 1591
页数:9
相关论文
共 50 条
  • [31] FLUX CHAMBER DESIGN AND OPERATION FOR THE MEASUREMENT OF MUNICIPAL SOLID-WASTE LANDFILL GAS EMISSION RATES
    REINHART, DR
    COOPER, DC
    WALKER, BL
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1992, 42 (08): : 1067 - 1070
  • [32] Quantitation of indoor air concentrations of volatile organic compounds (VOC) released of baking ovens under practical condition of usage in the scope of emission test chamber examinations
    Kuehn, C.
    Mendrok, V.
    Bauer, A.
    Frank, G.
    Schelle, C.
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2015, 75 (09): : 360 - 372
  • [33] Determination of the emission of volatile organic compounds from leathers by 20L small chamber method
    Kita, KJ
    6TH ASIAN INTERNATIONAL CONFERENCE OF LEATHER SCIENCE AND TECHNOLOGY, 2004, : 129 - 134
  • [34] Nitrous oxide emission from an agricultural field: Comparison between measurements by flux chamber and micrometerological techniques
    Christensen, S
    Ambus, P
    Arah, JRM
    Clayton, H
    Galle, B
    Griffith, DWT
    Hargreaves, KJ
    Klemedtsson, L
    Lind, AM
    Maag, M
    Scott, A
    Skiba, U
    Smith, KA
    Welling, M
    Wienhold, FG
    ATMOSPHERIC ENVIRONMENT, 1996, 30 (24) : 4183 - 4190
  • [35] Dynamic flux chamber measurements of hydrogen sulfide emission rate from a quiescent surface - A computational evaluation
    Prata, Ademir A., Jr.
    Santos, Jane M.
    Beghi, Sandra P.
    Fernandes, Isabella F.
    Vom Marttens, Lya L. C.
    Neto, Leovegildo I. Pereira
    Martins, Ramon S.
    Reis, Neyval C., Jr.
    Stuetz, Richard M.
    CHEMOSPHERE, 2016, 146 : 426 - 434
  • [36] Flux chamber measurements of anomalous CO2 emission from the flanks of Mammoth Mountain, California
    Rahn, TA
    Fessenden, JE
    Wahlen, M
    GEOPHYSICAL RESEARCH LETTERS, 1996, 23 (14) : 1861 - 1864
  • [37] Nitrous oxide emission from an agricultural field: Comparison between measurements by flux chamber and micrometeorological techniques
    Copenhagen Univ, Copenhagen, Denmark
    Atmos Environ, 24 (4183-4190):
  • [38] Biogenic volatile organic compound ambient mixing ratios and emission rates in the Alaskan Arctic tundra
    Angot, Helene
    McErlean, Katelyn
    Hu, Lu
    Millet, Dylan B.
    Hueber, Jacques
    Cui, Kaixin
    Moss, Jacob
    Wielgasz, Catherine
    Milligan, Tyler
    Ketcherside, Damien
    Bret-Harte, M. Syndonia
    Helmig, Detlev
    BIOGEOSCIENCES, 2020, 17 (23) : 6219 - 6236
  • [39] Volatile organic compound concentrations and emission rates in new manufactured and site-built houses
    Hodgson, AT
    Rudd, AF
    Beal, D
    Chandra, S
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2000, 10 (03): : 178 - 192
  • [40] EFFECTS OF SELECTED PROCESS PARAMETERS ON EMISSION RATES OF VOLATILE ORGANIC-CHEMICALS FROM CARPET
    HAWKINS, NC
    LUEDTKE, AE
    MITCHELL, CR
    LOMENZO, JA
    BLACK, MS
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1992, 53 (05): : 275 - 282