STABILITY OF THE ARTERIAL TO END-TIDAL CARBON-DIOXIDE DIFFERENCE DURING ANESTHESIA FOR PROLONGED NEUROSURGICAL PROCEDURES

被引:20
|
作者
SHARMA, SK [1 ]
MCGUIRE, GP [1 ]
CRUISE, CJE [1 ]
机构
[1] UNIV TORONTO, TORONTO WESTERN HOSP, DEPT ANAESTHESIA, TORONTO, ON M5T 2S8, CANADA
关键词
ANESTHESIA; NEUROSURGERY; CARBON DIOXIDE; MONITORING; TENSION; ARTERIAL; GRADIENTS; END-TIDAL; MEASUREMENT; CAPNOMETRY;
D O I
10.1007/BF03011688
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
This study was undertaken to examine the variation of the arterial to end-tidal PCO2 (Pa-PETCO(2)) difference during prolonged neurosurgical anaesthesia. Hyperventilation is open used to reduce intracranial pressure in neurosurgical patients. Continuous end-tidal CO2 monitoring is used as a guide between arterial CO2 measurements. We examined the stability of the Pa-PETCO(2) difference in 21 patients undergoing elective craniotomies lasting greater than four hours. A balanced neuroanaesthetic technique was used with the ventilation variables at the discretion of the attending anaesthetist. Once patients were positioned for surgery simultaneous samples of arterial PCO2 through an arterial catheter, and end-tidal PCO2 via a mass spectrometer were obtained. The Pa-PETCO(2) differences of each patient were plotted against time and a slope was derived with simple linear regression. The mean slope for all patients was then computed. There were no changes in the Pa-PETCO(2) difference with time (P > 0.05) suggesting a constant relationship between the arterial and end-tidal PCO2 measurements over time. We conclude that end-tidal PCO2 can be used as a reliable guide to estimate arterial PCO2 during neurosurgical procedures of greater than four hours duration once the Pa-PETCO(2) difference has been established.
引用
收藏
页码:498 / 503
页数:6
相关论文
共 50 条
  • [41] EFFECT OF EPINEPHRINE ON END-TIDAL CARBON-DIOXIDE MONITORING DURING CPR
    MARTIN, GB
    GENTILE, NT
    PARADIS, NA
    MOEGGENBERG, J
    APPLETON, TJ
    NOWAK, RM
    ANNALS OF EMERGENCY MEDICINE, 1990, 19 (04) : 396 - 398
  • [42] OBSERVATIONS ON END-TIDAL CARBON-DIOXIDE DURING EXPERIMENTAL CARDIOPULMONARY ARREST
    GRUNDLER, WG
    WEIL, MH
    BISERA, J
    RACKOW, EC
    CLINICAL RESEARCH, 1984, 32 (03): : A672 - A672
  • [43] END-TIDAL CARBON-DIOXIDE AS A NONINVASIVE MONITOR DURING CARDIOPULMONARY RESUSCITATION
    NIELSEN, M
    FITCHETT, A
    CRITICAL CARE MEDICINE, 1989, 17 (12) : 1365 - 1365
  • [44] ELEVATED END-TIDAL CARBON-DIOXIDE DURING THORACOSCOPY - AN UNUSUAL CAUSE
    BILES, DT
    CARROLL, GJ
    SMITH, MV
    FLYNN, RT
    ANESTHESIOLOGY, 1994, 80 (04) : 953 - 955
  • [45] END-TIDAL CARBON-DIOXIDE MONITORING DURING CARDIOPULMONARY-RESUSCITATION
    GARNETT, AR
    ORNATO, JP
    GONZALEZ, ER
    JOHNSON, EB
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1987, 257 (04): : 512 - 515
  • [46] END-TIDAL CARBON-DIOXIDE MEASUREMENT DURING PEDIATRIC ANESTHESIA - THE INFLUENCE OF SITE OF MEASUREMENT AND RESPIRATORY RATE
    FRETSCHNER, R
    WARTH, H
    DEUSCH, H
    KLOSS, T
    ANAESTHESIST, 1992, 41 (08): : 463 - 467
  • [47] END-TIDAL CARBON-DIOXIDE MEASUREMENT DURING PEDIATRIC ANESTHESIA - THE INFLUENCE OF SITE OF MEASUREMENT AND RESPIRATORY RATE
    LINK, J
    SCHAFFARTZIK, W
    ANAESTHESIST, 1993, 42 (02): : 115 - 117
  • [48] ACCURACY OF END-TIDAL CARBON-DIOXIDE TENSION ANALYZERS
    RAEMER, DB
    CALALANG, I
    JOURNAL OF CLINICAL MONITORING, 1991, 7 (02): : 195 - 208
  • [49] Relationship between arterial and end-tidal carbon dioxide pressures during anesthesia using a laryngeal tube
    Lee, JS
    Nam, SB
    Chang, CH
    Han, DW
    Lee, YW
    Shin, CS
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (06) : 759 - 762
  • [50] CARDIAC-OUTPUT AND END-TIDAL CARBON-DIOXIDE
    WEIL, MH
    BISERA, J
    TREVINO, RP
    RACKOW, EC
    CRITICAL CARE MEDICINE, 1985, 13 (11) : 907 - 909