Regenerative Active Electronic Load for Testing Power Transformers Under Linear and Nonlinear Conditions

被引:2
|
作者
de Sousa, Clodualdo Venicio [1 ]
de Rezende, Guilherme Monteiro [1 ,2 ]
Matos, Frederico Ferreira [1 ,2 ]
Silva, Selenio Rocha [2 ]
Mendes, Victor Flores [2 ]
机构
[1] Fed Univ Itajuba UNIFEI, Dept Elect Engn, Itabira, Brazil
[2] Univ Fed Minas Gerais, Dept Elect Engn, Belo Horizonte, MG, Brazil
关键词
Active electronic load; Regenerative load; Load simulator; Back-to-back converter; Power transformer; Resonant control;
D O I
10.1007/s40313-015-0220-4
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A significant number of power apparatus, before being commercialized or during maintenance, are submitted to laboratory tests where real operation conditions are emulated. These tests generally demand high energy consumption which increases the maintenance costs and the overall equipment investment. This paper proposes a platform to test power transformers with return of energy (closed loop) to the system, reducing the power consumption to the inherent equipment losses. Besides the low energy consumption, the proposed system permits flexible tests and operation with variable power factor. The transformer under test can be submitted to different load profiles, including harmonics injection, which is not generally addressed in the traditional procedures. The control structure and constructive characteristics of a 75-kVA test bench are presented and the methodology is validated by testing a 50-kVA distribution transformer. The experimental results are discussed, and the overall system efficiency is demonstrated.
引用
收藏
页码:105 / 117
页数:13
相关论文
共 50 条
  • [21] Picking an electronic load for power source testing
    Chroma Systems Solutions, Irvine, CA, United States
    Electron Prod Garden City NY, 2009, 3
  • [22] State of the Art of Active Power Electronic Transformers for Smart Grids
    Roasto, Indrek
    Romero-Cadaval, Enrique
    Martins, Joao
    Smolenski, Robert
    38TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2012), 2012, : 5241 - 5246
  • [23] Evaluation of Power Transformer Loses Measurements Methods Under Nonlinear Load Conditions
    Damjanovic, Aleksandar
    Integlia, Ryan
    Sarwat, Arif
    2016 IEEE/IAS 52ND INDUSTRIAL AND COMMERCIAL POWER SYSTEMS TECHNICAL CONFERENCE (I&CPS), 2016,
  • [24] Power transformers life expectancy under distorting power electronic loads
    Pierrat, L
    Resende, MJ
    Santana, J
    ISIE'96 - PROCEEDINGS OF THE IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, VOLS 1 AND 2, 1996, : 578 - 583
  • [25] A new on-load tap changing system with power electronic elements for power transformers
    Li, XM
    Liao, QF
    Yin, XG
    Xie, JH
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 556 - 559
  • [26] Virtual Load with Common Mode Active Filtering for Power Hardware-In-the-Loop Testing of Power Electronic Converters
    Bojoi, R.
    Armando, E.
    Rosu, S. G.
    Vaschetto, S.
    Soccio, P.
    IECON 2014 - 40TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2014, : 1875 - 1881
  • [27] TESTING PULSE TRANSFORMERS UNDER MASS-PRODUCTION CONDITIONS
    VDOVIN, SS
    MEASUREMENT TECHNIQUES-USSR, 1967, (08): : 998 - &
  • [28] On Power Factor Improvement by Lossless Linear Filters under Nonlinear Nonsinusoidal Conditions
    del Puerto-Flores, Dunstano
    Ortega, Romeo
    Scherpen, Jacquelien M. A.
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (01): : 112 - 117
  • [29] Performance Tolerant Control of Shunt Active Power Filter Under Unbalanced Nonlinear Load
    Frifita, K.
    Boussak, M.
    Naamane, A.
    M'Sirdi, N.
    2015 16TH INTERNATIONAL CONFERENCE ON SCIENCES AND TECHNIQUES OF AUTOMATIC CONTROL AND COMPUTER ENGINEERING (STA), 2015, : 278 - 283
  • [30] Power Electronic Traction Transformer: Efficiency Improvements Under Light-Load Conditions
    Besselmann, Thomas
    Mester, Akos
    Dujic, Drazen
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (08) : 3971 - 3981