A double-beam laser absorption detection system for high-performance liquid chromatography (HPLC) using the thermal lens effect has been developed. An electronic circuit is used to reduce the background noise level. The circuit is based on direct subtraction of reference and signal photocurrents under feedback control. A practical intensity signal-to-noise (S/N) ratio of 5 x 10(-6) for normal absorption and 1 x 10(-5) for thermal lens absorption measurements is achieved. The thermal-lens enhancement per unit laser power is 0.62 mW-1. For a 34-mW beam power at the sample cell, the absorption signal is 22 times higher in comparison to normal absorption. The system is shown to have a noise level of 2 x 10(-7) AU. Amounts as low as 1 x 10(-10) M 2'-(Cl-4-dimethylaminoazobenzene at the flow cell or 1.5 fmol injected can be detected (S/N = 3). This corresponds to a 10-fold improvement in comparison to normal absorption measurements with the same electronic canceller and a 100-fold improvement in comparison to those for commercial absorption detectors.
引用
收藏
页码:1175 / 1179
页数:5
相关论文
共 50 条
  • [21] LASER-INDUCED FLUORESCENCE DETECTION FOR CONVENTIONAL AND MICROCOLUMN LIQUID-CHROMATOGRAPHY
    FOLESTAD, S
    JOHNSON, L
    JOSEFSSON, B
    GALLE, B
    ANALYTICAL CHEMISTRY, 1982, 54 (06) : 925 - 929
  • [22] Diode laser-based absorption detector for conventional-size liquid chromatography
    Mank, AJG
    deNijs, H
    Lingeman, H
    Brinkman, UAT
    Velthorst, NH
    Gooijer, C
    APPLIED SPECTROSCOPY, 1996, 50 (01) : 28 - 34
  • [23] DOUBLE-BEAM LASER-EXCITED INDIRECT FLUOROMETRIC DETECTION OF NONELECTROLYTES IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    TAKEUCHI, T
    YEUNG, ES
    JOURNAL OF CHROMATOGRAPHY, 1986, 366 : 145 - 152
  • [24] CHITOSAN-BASED STATIONARY PHASES IN MICROCOLUMN LIQUID-CHROMATOGRAPHY
    JINNO, K
    OGURA, S
    TAKAYAMA, K
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1990, 13 (05): : 323 - 327
  • [25] LASER PHOTOIONIZATION TECHNIQUE FOR CONVENTIONAL, SEMI-MICROCOLUMN AND MICROCOLUMN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KAWAZUMI, H
    MATSUMOTO, T
    SATO, N
    YAMADA, S
    OGAWA, T
    ANALYTICAL SCIENCES, 1988, 4 (02) : 191 - 194
  • [26] Broadband Laser-Based Infrared Detector for Gas Chromatography
    Tomberg, Teemu
    Vuorio, Niko
    Hieta, Tuomas
    Jussila, Matti
    Hartonen, Kari
    Vainio, Markku
    Mikkonen, Tommi
    Toivonen, Juha
    Riekkola, Marja-Liisa
    Halonen, Lauri
    Metsala, Markus
    ANALYTICAL CHEMISTRY, 2020, 92 (21) : 14582 - 14588
  • [27] OPEN TUBULAR LIQUID-CHROMATOGRAPHY WITH THERMAL LENS DETECTION
    SEPANIAK, MJ
    VARGO, JD
    KETTLER, CN
    MASKARINEC, MP
    ANALYTICAL CHEMISTRY, 1984, 56 (08) : 1252 - 1257
  • [28] DETECTION METHOD FOR ION CHROMATOGRAPHY BASED ON DOUBLE-BEAM LASER-EXCITED INDIRECT FLUOROMETRY
    MHO, SI
    YEUNG, ES
    ANALYTICAL CHEMISTRY, 1985, 57 (12) : 2253 - 2256
  • [29] THERMAL LENS CIRCULAR-DICHROISM DETECTOR FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OPTICAL RESOLUTIONS
    XU, MR
    TRAN, CD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 200 : 163 - ANYL
  • [30] DIFFERENTIAL THERMAL LENS SPECTROMETRY BASED ON HIGH-FREQUENCY MODULATION AND ROTOREFLECTIVE DOUBLE-BEAM CONFIGURATION
    YANG, Y
    HALL, SC
    APPLIED SPECTROSCOPY, 1988, 42 (01) : 72 - 76