ACCURACY OF DEXA MEASUREMENT OF BONE-MINERAL DENSITY AFTER TOTAL HIP-ARTHROPLASTY

被引:123
|
作者
COHEN, B
RUSHTON, N
机构
来源
关键词
D O I
10.1302/0301-620X.77B3.7744941
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Dual-energy X-ray absorptiometry (DEXA) is increasingly used to measure changes in bone mineral density (BMD) around femoral prostheses after total hip arthroplasty, We have studied the factors which affect the accuracy of these measurements. The coefficient of variation was <2% using a hydroxyapatite phantom, 2.7% in an anthropomorphic phantom specimen, and <1% in repeated measurements on implanted cadaver femora, The precision did not vary with different implant materials or designs. In patients we found a mean precision error of 2.7% to 3.4%, The most significant factor affecting reproducibility was rotation of the femur. We conclude that DEXA is a precise method of measurement for small changes in BMD around femoral implants, but that correct and careful positioning of patients is essential to obtain reliable results.
引用
收藏
页码:479 / 483
页数:5
相关论文
共 50 条
  • [31] EXCISION OF HETEROTOPIC BONE FOLLOWED BY IRRADIATION AFTER TOTAL HIP-ARTHROPLASTY
    WARREN, SB
    BROOKER, AF
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (02): : 201 - 210
  • [32] BONE IMAGING AFTER CEMENTLESS PRESS FIT TOTAL HIP-ARTHROPLASTY
    LETTE, J
    EYBALIN, MC
    ROY, A
    CERINO, M
    PRENOVAULT, J
    DESJARDINS, A
    DUCHESNE, R
    BAH, C
    FALLAHA, M
    LEVASSEUR, A
    CLINICAL NUCLEAR MEDICINE, 1989, 14 (08) : 614 - 622
  • [33] Measuring bone mineral density of the pelvis and proximal femur after total hip arthroplasty
    Wilkinson, JM
    Peel, NFA
    Elson, RA
    Stockley, I
    Eastell, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (02): : 283 - 288
  • [35] Effect of implant composition on periprosthetic bone mineral density after total hip arthroplasty
    Akira Morita
    Naomi Kobayashi
    Hyonmin Choe
    Taro Tezuka
    Toshihiro Misumi
    Yutaka Inaba
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 2763 - 2771
  • [36] Effect of implant composition on periprosthetic bone mineral density after total hip arthroplasty
    Morita, Akira
    Kobayashi, Naomi
    Choe, Hyonmin
    Tezuka, Taro
    Misumi, Toshihiro
    Inaba, Yutaka
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (05) : 2763 - 2771
  • [37] Stem anteversion affects periprosthetic bone mineral density after total hip arthroplasty
    Hayashi, Shinya
    Hashimoto, Shingo
    Kanzaki, Noriyuki
    Kuroda, Ryosuke
    Kurosaka, Masahiro
    HIP INTERNATIONAL, 2016, 26 (03) : 260 - 264
  • [38] FAILURE PATTERNS AFTER TOTAL HIP-ARTHROPLASTY
    WROBLEWSKI, BM
    BRITISH MEDICAL JOURNAL, 1983, 286 (6363): : 476 - 476
  • [39] TOTAL HIP-ARTHROPLASTY AFTER SCHANZ OSTEOTOMY
    SKOGLUND, A
    REIGSTAD, A
    ACTA ORTHOPAEDICA SCANDINAVICA, 1985, 56 (03): : 281 - 282
  • [40] TOTAL HIP-ARTHROPLASTY
    SIOPACK, JS
    JERGESEN, HE
    WESTERN JOURNAL OF MEDICINE, 1995, 162 (03): : 243 - 249