Numerical Study on Flow Field for a Solar Collector at Various Inflow Incidence Angles

被引:0
|
作者
Hsu, Uzu-Kuei
Chang, Keh-Chin [1 ]
Chuang, Chung-Chin
机构
[1] Air Force Inst Technol, Dept Aircraft Engn, 1 Jyulun Rd, Kaohsiung 82063, Taiwan
来源
JOURNAL OF AERONAUTICS ASTRONAUTICS AND AVIATION | 2014年 / 46卷 / 04期
关键词
Solar collector; Incidence angle; Spoiler; Semi-implicit method for pressure-linked equation (SIMPLE) algorithm; Turbulence;
D O I
10.6125/14-0728-808
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Previous studies on solar water heaters (SWHs) have primarily focused on the thermal efficiency of a solar collector and structural safety. This study applied a numerical simulation method to examine the characteristics of flowfield. In addition, a solar collector of a SWH was employed to investigate the distribution of average surface pressure and vortex structure for various inflow incidence angles as well as the influence of two types of spoiler. This study adopted a computational fluid dynamics fluid mechanics method, an incompressible flow algorithm (i.e., semi-implicit method for pressure-linked equation [SIMPLE]), to simulate the flow field of the solar collector. A turbulence model (realizable k-epsilon model) was adopted. The obtained numerical values were compared with the experimental results. Because the simulation data were approximated to the experimental results, the turbulence strength and length were set as 11.7% and 0.12, respectively. The parameter for this study was inflow angle (theta = 15 degrees, 22.5 degrees, 30 degrees, 37.5 degrees, and V = 35 m/s). The characteristics of the flow field for various spoilers at inflow angle (theta) = 22.5 degrees were examined. According to the numerical simulation results, the low-pressure area on the upper surface of the solar collector first enlarged and then diminished as the inflow angle increased. The largest low-pressure area occurred at the wind incidence angle (theta) = 30 degrees. Because the cross-sectional aspect ratio in the frontal view changed, the overall lift force increased as the angle. increased. Because the vertical inflow cross-sectional area changed, air resistance gradually reduced. After spoilers of various sizes were installed, inflow airflow directly hit the solar collector, thereby reducing the pressure difference between the upper and lower surfaces of the solar collector. When the length of the spoiler increased, the shielding effect was enhanced; therefore, the increased size of the spoiler gradually reduced the lift force.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 50 条
  • [41] ANALYSIS OF TEXTURED SOLAR-CELLS AT VARIOUS ANGLES OF INCIDENCE - FRESNEL CONCENTRATION TO 500 SUNS
    SMITH, AW
    SOLAR ENERGY MATERIALS AND SOLAR CELLS, 1994, 32 (01) : 37 - 51
  • [42] Performance study of solid oxide fuel cell with various flow field designs: numerical study
    Saied, M.
    Ahmed, K.
    Nemat-Alla, M.
    Ahmed, M.
    El-Sebaie, M.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2018, 43 (45) : 20931 - 20946
  • [43] A Sensitivity Study of Gas Turbine Exhaust Diffuser-Collector Performance at Various Inlet Swirl Angles and Strut Stagger Angles
    Siorek, Michal P.
    Guillot, Stephen
    Xue, Song
    Ng, Wing F.
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2018, 140 (07):
  • [44] Numerical Study on the Effect of Distribution Plates in the Manifolds on the Flow Distribution and Thermal Performance of a Flat Plate Solar Collector
    Manuel Garcia-Guendulain, Juan
    Manuel Riesco-Avila, Jose
    Elizalde-Blancas, Francisco
    Manuel Belman-Flores, Juan
    Serrano-Arellano, Juan
    ENERGIES, 2018, 11 (05)
  • [45] A SENSITIVITY STUDY OF GAS TURBINE EXHAUST DIFFUSER-COLLECTOR PERFORMANCE AT VARIOUS INLET SWIRL ANGLES AND STRUT STAGGER ANGLES
    Siorek, Michal P.
    Guillot, Stephen
    Xue, Song
    Ng, Wing F.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 2B, 2017,
  • [46] Numerical study ofantifreeze performance of flat-plate solar collector
    影响太阳能平板集热器抗冻性能因素分析
    Ji, Jie (jijie@ustc.edu.cn), 2018, Science Press (39):
  • [47] Numerical Study and Optimization of Parabolic Trough Solar Collector Receiver Tube
    Ghomrassi, Anissa
    Mhiri, Hatem
    Bournot, Philippe
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2015, 137 (05):
  • [48] Numerical Simulation Study of a New Type Solar Collector Wall System
    Xu, Shuhui
    Zhang, Fengjiao
    Wang, Jiankai
    Liu, Chang
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 98 - +
  • [49] NUMERICAL STUDY OF THE WIND TURBINE WAKE FLOW AND EFFECTS OF THE INFLOW TURBULENCE
    Luo, Xiaoyu
    Lu, Shengyu
    CIVIL ENGINEERING JOURNAL-STAVEBNI OBZOR, 2018, 27 (04): : 548 - 560
  • [50] Numerical study and experimental validation on the optimization of the large size solar collector
    Zhou, Fan
    Ji, Jie
    Yuan, Weiqi
    Cai, Jingyong
    Tang, Wenxue
    Modjinou, Mawufemo
    APPLIED THERMAL ENGINEERING, 2018, 133 : 8 - 20