Agreement and Repeatability of an Infrared Thermometer

被引:9
|
作者
Kelechi, Teresa J. [1 ]
Good, Angela [2 ]
Mueller, Martina [1 ]
机构
[1] Med Univ South Carolina, Charleston, SC 29425 USA
[2] Duke Univ, Med Ctr, Durham, NC 27706 USA
基金
美国国家卫生研究院;
关键词
skin; temperature; infrared; thermometry;
D O I
10.1891/1061-3749.19.1.55
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Recently, manufacturers have devised thermometers for home use by patients, such as the TempTouch Infrared Thermometer (TTIR; Diabetica Solutions, San Antonio, TX), winch is designed with a long handle that can be used for self-monitoring localized skin temperature of the feet and legs. This study assessed the level of agreement and repeatability of the TTIR. compared to a thermistor-type thermometer (TT; PeriFlux, 5020 Temperature Unit, Perimed, Stockholm, Sweden), the reference standard. In 17 healthy subjects, localized skin temperature was measured 8 cm above the right medial malleolus at baseline (Time 1), after a 10-minute rest period (Time 2), and after 10 minutes of cold provocation (Time 3) with a cryotherapy gel wrap placed around the lower legs using the TTIR and TT for temperature measurement. Scatter plots and correlation coefficients showed strong positive relationships between the two measurement methods at all three time points (Time 1: r = 0.95; Time 2: r = 0.97; and, Time 3: r = 0.87). Results showed a reasonable level of agreement between the two methods at Times 1 and 2 but not after cold provocation. Agreement between the methods appears to be better than repeatability within each method. Results for repeatability from both the TT and TTIR were very similar suggesting that there was a systematic bias with increasing temperatures between Time 1 and Time 2.
引用
收藏
页码:55 / 64
页数:10
相关论文
共 50 条
  • [21] Repeatability intraexaminer and agreement in amplitude of accommodation measurements
    B. Antona
    F. Barra
    A. Barrio
    E. Gonzalez
    I. Sanchez
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2009, 247 : 121 - 127
  • [22] Repeatability and agreement in the measurement of horizontal fusional vergences
    Antona, B.
    Barrio, A.
    Barra, F.
    Gonzalez, E.
    Sanchez, I.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2008, 28 (05) : 475 - 491
  • [23] Repeatability and agreement of an automated and objective cover test
    Mestre, Clara
    Otero Molins, Carles
    Diaz-Douton, Fernando
    Gautier, Josselin
    Pujol, Jaume
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [24] The determination of cutaneous temperature in cows with infrared thermometer comparing to a thermocouple thermometer
    Pusta, D
    Bulletin of the University of Agricultural Sciences and Veterinary Medicine, Vol 60: VETERINARY MEDICINE, 2003, 60 : 135 - 137
  • [25] Improved infrared thermometer with laser optics
    不详
    APPITA JOURNAL, 1998, 51 (05): : 394 - 394
  • [26] INFRARED THERMOMETER WITH PYROELECTRIC DETECTOR.
    Shigiyama, Keigoro
    Akiyama, Masaki
    Kitahori, Kiyoharu
    Yoshikawa, Takashi
    Nakamura, Kunio
    Yamaka, Eiso
    National Technical Report (Matsushita Electric Industry Company), 1972, 18 (02): : 153 - 164
  • [27] A SIMPLE METHOD TO CALIBRATE AN INFRARED THERMOMETER
    SADLER, EJ
    VANBAVEL, CHM
    AGRONOMY JOURNAL, 1982, 74 (06) : 1096 - 1098
  • [28] Evaluation of the performance of an infrared tympanic thermometer
    Cascetta, Furio
    Measurement: Journal of the International Measurement Confederation, 1995, 16 (04): : 239 - 246
  • [29] THE C-600 INFRARED THERMOMETER
    不详
    CONFECTIONERY PRODUCTION, 1985, 51 (08): : 445 - 445
  • [30] An infrared forehead thermometer for flap monitoring
    Estrella, Emmanuel P.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2009, 62 (06): : 736 - 736