FULL-FIELD VIBROMETRY USING A FABRY-PEROT ETALON INTERFEROMETER

被引:2
|
作者
OURSLER, DA
WAGNER, JW
机构
[1] Center for Nondestructive Evaluation, The Johns Hopkins University, Baltimore, MD, 21218
来源
APPLIED OPTICS | 1992年 / 31卷 / 34期
关键词
FABRY-PEROT INTERFEROMETER; VIBROMETRY; OPTICAL DEVICE;
D O I
10.1364/AO.31.007301
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A solid lithium niobate Fabry-Perot etalon interferometer has been investigated with regard to its potential to perform full-field vibrometry. Predictions of theoretical system sensitivity were made based on signal-to-noise calculations. Optimized equations governing the etalon behavior were developed and examined in light of experimental results. The ability of the etalon system to accomplish multiple-(two-)-point simultaneous detection and full-field scanned vibrometry was demonstrated experimentally as well. The possibility of future work to obtain a snapshot image of an ultrasonic wave front is discussed.
引用
收藏
页码:7301 / 7308
页数:8
相关论文
共 50 条
  • [1] Measuring the etalon quality of the GREGOR Fabry-Perot interferometer
    Verma, Meetu
    Denker, Carsten
    JOURNAL OF ASTRONOMICAL TELESCOPES INSTRUMENTS AND SYSTEMS, 2020, 6 (01)
  • [2] INTENSITY TRANSMITTED BY A FABRY-PEROT ETALON WITH ANOTHER INTERNAL FABRY-PEROT-INTERFEROMETER
    BERNABEU, E
    AMARE, JC
    ALVAREZ, JM
    MORENO, F
    APPLIED OPTICS, 1981, 20 (12): : 2117 - 2120
  • [3] ON FIELD DISTRIBUTIONS IN A FABRY-PEROT INTERFEROMETER
    LOTSCH, HKV
    PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1965, 53 (05): : 489 - &
  • [4] Modernization of a Fabry-Perot Etalon
    Efimkov, V. F.
    Zubarev, I. G.
    Mikhailov, S. I.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2018, 61 (01) : 114 - 115
  • [5] ON THE FINESSE OF THE FABRY-PEROT ETALON
    POPESCU, G
    REVUE ROUMAINE DE PHYSIQUE, 1981, 26 (07): : 719 - 723
  • [6] Investigation of AFLCs using Fabry-Perot etalon
    Gupta, SJ
    Gharde, RA
    Tripathi, A
    XIV CONFERENCE ON LIQUID CRYSTALS: CHEMISTRY, PHYSICS, AND APPLICATIONS, 2001, 4759 : 135 - 140
  • [7] Fabry-Perot etalon filter
    Wang, QM
    Zhang, YM
    Liu, WH
    ICO20: OPTICAL INFORMATION PROCESSING, PTS 1 AND 2, 2006, 6027
  • [8] SCANNING FABRY-PEROT INTERFEROMETER FOR FIELD USE
    BRANNON, PJ
    APPLIED OPTICS, 1971, 10 (08) : 1977 - +
  • [9] A PHOTOELECTRIC STELLAR SPECTROPHOTOMETER, USING A FABRY-PEROT ETALON
    GEAKE, JE
    WILCOCK, WL
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 1957, 117 (04) : 380 - &
  • [10] Laser profilometer using a Fabry-Perot etalon and an objective
    Lin, Shyh-Tsong
    Yeh, Sheng-Lih
    Wang, Yi-Chun
    Chen, Meng-Zhu
    SENSORS AND ACTUATORS A-PHYSICAL, 2013, 203 : 47 - 51