EFFECT OF MEASURING AMBULATORY BLOOD-PRESSURE ON SLEEP AND ON BLOOD-PRESSURE DURING SLEEP

被引:104
|
作者
DAVIES, RJO
JENKINS, NE
STRADLING, JR
机构
[1] Osler Chest Unit, Churchill Hospital
来源
BRITISH MEDICAL JOURNAL | 1994年 / 308卷 / 6932期
关键词
D O I
10.1136/bmj.308.6932.820
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective-To assess whether recording of ambulatory blood pressure at night causes arousal from sleep and a change in the continuous blood pressure recorded simultaneously. Design-Repeated measurement of blood pressure with two ambulatory blood pressure machines (Oxford Medical ABP and A&D TM2420) during continuous measurement of beat to beat blood pressure and continuous electroencephalography. Setting-Sleep reseach laboratory. Subjects-Six normal subjects. Main outcome measures-The duration of electroencephalographic arousal and the beat to beat changes in blood pressure produced by the measurement of ambulatory blood pressure; the size of any changes that this arousal and change in blood pressure produced in the blood pressure recorded by the ambulatory machine. Results-Both ambulatory blood pressure machines caused arousal from sleep: the mean duration of arousal was 16 seconds (95% range 0-202) with the ABP and 8 seconds (0-73) with the TM2420. Both also caused a rise in beat to beat blood pressure. During non-rapid eye movement sleep, this rise led to the ABP machine overestimating the true systolic blood pressure during sleep by a mean of 10 (SD 14.8) mm Hg and the TM2420 by a mean of 6.3 (8.2) mm Hg. On average, diastolic pressure was not changed, but measurements in individual subjects changed by up to 23 mm Hg. These changes varied in size among subjects and stages of sleep and were seen after measurements that did not cause any electroencephalographic arousal. Conclusions-Ambulatory blood pressure machines cause appreciable arousal from sleep and therefore alter the blood pressure that they are trying to record. This effect should be taken into account when recordings of blood pressure at night are interpreted in clinical work and epidemiological research.
引用
收藏
页码:820 / 823
页数:4
相关论文
共 50 条
  • [41] AMBULATORY BLOOD-PRESSURE RECORDER
    STEIN, IM
    PETERSON, R
    LEE, A
    MEDICAL INSTRUMENTATION, 1983, 17 (05): : 352 - 354
  • [42] AMBULATORY MONITORING OF BLOOD-PRESSURE
    WHELTON, A
    HOSPITAL PRACTICE, 1991, 26 : 13 - 19
  • [43] AMBULATORY BLOOD-PRESSURE RECORDINGS
    CLEMENT, DL
    ACTA CARDIOLOGICA, 1987, 42 (04) : 237 - 241
  • [44] AMBULATORY BLOOD-PRESSURE MONITORING
    DUGGAN, J
    PHARMACOLOGY & THERAPEUTICS, 1994, 63 (03) : 313 - 321
  • [45] AMBULATORY MONITORING OF BLOOD-PRESSURE
    GERMANO, G
    DAMIANI, S
    FORNARELLI, M
    CASSONE, R
    CALCAGNINI, G
    CORSI, V
    MINERVA CARDIOANGIOLOGICA, 1982, 30 (03): : 57 - 64
  • [46] AMBULATORY BLOOD-PRESSURE MONITORING
    NICHOLSON, WR
    MATTHEWS, JNS
    OSULLIVAN, JJ
    WREN, C
    ARCHIVES OF DISEASE IN CHILDHOOD, 1993, 69 (06) : 681 - 684
  • [47] AMBULATORY BLOOD-PRESSURE AND PROGNOSIS
    PICKERING, TG
    JAMES, GD
    JOURNAL OF HYPERTENSION, 1994, 12 : S29 - S33
  • [48] REPRODUCIBILITY OF AMBULATORY BLOOD-PRESSURE
    MANN, S
    GOULD, BA
    CRAIG, MWM
    RAFTERY, EB
    CLINICAL SCIENCE, 1985, 68 : P42 - P42
  • [49] EFFECT OF CAROTID ENDARTERECTOMY ON BLOOD-PRESSURE MEASURED AT HOME BY CONTINUOUS AMBULATORY BLOOD-PRESSURE MONITORING
    FINCH, D
    DOODS, SR
    COWAN, AR
    SHUFF, AM
    DAVIES, JN
    CHANT, AD
    BRITISH JOURNAL OF SURGERY, 1995, 82 (04) : 549 - 550
  • [50] AMBULATORY BLOOD-PRESSURE MONITORING
    RAMOS, F
    PRENSA MEDICA ARGENTINA, 1991, 78 (05): : 200 - 205