INTERNATIONAL COMPARISON OF 2 IODINE-STABILIZED HE-NE LASERS AT LAMBDA-APPROXIMATE-TO-543NM

被引:6
|
作者
SIMONSEN, HR [1 ]
BRAND, U [1 ]
RIEHLE, F [1 ]
机构
[1] PHYS TECH BUNDESANSTALT,D-38116 BRAUNSCHWEIG,GERMANY
关键词
D O I
10.1088/0026-1394/31/5/001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An intercomparison of two I-127(2) stabilized He-Ne lasers at lambda almost-equal-to 543 nm, recommended as length standards, has been made between the DFM and the PTB, and is the first international comparison at this wavelength reported so far. Both lasers use saturated absorption of iodine in an external cell, one (PTB) using frequency-modulation spectroscopy, the other (DFM) using the first or third harmonic detection techniques. The range of the frequency differences between the two lasers was from 11,8 kHz to 18,4 kHz, with a mean of DELTA(f) = 14,4 kHz and a standard uncertainty of 1,9 kHz. A minimum value for the two-probe relative standard uncertainty of 2,5 x 10(-13) (140 Hz) is reached after 5 000 s. The hyperfine line splittings were measured by the beat-frequency technique, and good agreement was found between the two completely different laser systems. Measurements of frequency dependence on modulation amplitude, iodine pressure, and pump power are also reported.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [41] Optical frequency measurements with the global positioning system: tests with an iodine-stabilized He-Ne laser
    Fox, RW
    Diddams, SA
    Bartels, A
    Hollberg, L
    APPLIED OPTICS, 2005, 44 (01) : 113 - 120
  • [42] Comparison of 127I2-stabilized He-Ne lasers at 633 nm between the MIKES and the BIPM
    Hu, J
    Riski, K
    Chartier, A
    Picard, S
    METROLOGIA, 1997, 34 (05) : 417 - 419
  • [43] Comparison between the 127I2 stabilized He-Ne lasers wavelength standards at 633 nm
    Qian, Jin
    Liu, Xiu-Ying
    Huang, Xiao-Rong
    Zhang, Zhi-Quan
    Shi, Chun-Ying
    Tan, Hui-Ping
    Xin, Ming
    Wang, Han-Ping
    Cai, Shan
    Liu, Zhong-You
    Zhang, Xiao-Ping
    Jiliang Xuebao/Acta Metrologica Sinica, 2008, 29 (SUPPL.): : 127 - 130
  • [44] International comparison of two iodine-stabilized frequency-doubled Nd:YAG lasers at λ=532 nm
    Cordiale, P
    Galzerano, G
    Schnatz, H
    METROLOGIA, 2000, 37 (02) : 177 - 182
  • [45] COMPARISON BETWEEN THE I-127(2) STABILIZED HE-NE LASERS AT 633 NM AND 612 NM OF THE BIPM AND THE IMGC
    BERTINETTO, F
    CORDIALE, P
    PICOTTO, GB
    CHARTIER, JM
    FELDER, R
    GLASER, MG
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1983, 32 (01) : 72 - 76
  • [46] QUANTITATIVE DESCRIPTION OF SATURATED ABSORPTION SIGNAL IN IODINE STABILIZED HE-NE LASERS
    BRILLET, A
    CEREZ, P
    METROLOGIA, 1977, 13 (03) : 137 - 139
  • [47] SOME ASPECTS OF INTERNATIONAL COLLATION OF STABILIZED HE-NE/J2 LASERS
    KAPRALOV, VP
    PRIVALOV, VE
    OPTIKA I SPEKTROSKOPIYA, 1983, 55 (06): : 1101 - 1105
  • [48] PROPERTIES OF A He-Ne LASER AT lambda equals 612 NM, STABILIZED BY MEANS OF AN EXTERNAL IODINE ABSORPTION CELL.
    Glaser, Michael
    IEEE Transactions on Instrumentation and Measurement, 1986, IM-36 (02) : 604 - 608
  • [49] COMPARISON OF HE-NE LASERS FROM THE LMM AND THE IMGC STABILIZED ON 127I2 AT 633-NM
    DEVICENTE, J
    SANCHEZPEREZ, AM
    BERTINETTO, F
    METROLOGIA, 1994, 30 (05) : 503 - 506
  • [50] Lamb-dip stabilized 543-nm He-Ne lasers and isotope shift of Ne 3s2?2p10 transition
    W.-Y. Cheng
    J.-T. Shy
    Applied Physics B, 2000, 70 : 889 - 893