INTERNATIONAL COMPARISON OF 2 IODINE-STABILIZED HE-NE LASERS AT LAMBDA-APPROXIMATE-TO-543NM

被引:6
|
作者
SIMONSEN, HR [1 ]
BRAND, U [1 ]
RIEHLE, F [1 ]
机构
[1] PHYS TECH BUNDESANSTALT,D-38116 BRAUNSCHWEIG,GERMANY
关键词
D O I
10.1088/0026-1394/31/5/001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An intercomparison of two I-127(2) stabilized He-Ne lasers at lambda almost-equal-to 543 nm, recommended as length standards, has been made between the DFM and the PTB, and is the first international comparison at this wavelength reported so far. Both lasers use saturated absorption of iodine in an external cell, one (PTB) using frequency-modulation spectroscopy, the other (DFM) using the first or third harmonic detection techniques. The range of the frequency differences between the two lasers was from 11,8 kHz to 18,4 kHz, with a mean of DELTA(f) = 14,4 kHz and a standard uncertainty of 1,9 kHz. A minimum value for the two-probe relative standard uncertainty of 2,5 x 10(-13) (140 Hz) is reached after 5 000 s. The hyperfine line splittings were measured by the beat-frequency technique, and good agreement was found between the two completely different laser systems. Measurements of frequency dependence on modulation amplitude, iodine pressure, and pump power are also reported.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [1] Iodine-stabilized He-Ne laser at lambda=633 nm: Design and international comparison
    Popescu, G
    Chartier, JM
    Chartier, A
    OPTICAL ENGINEERING, 1996, 35 (05) : 1348 - 1352
  • [2] IODINE-STABILIZED HE-NE LASERS AT LAMBDA = 633 NM OF A COMPACT CONSTRUCTION
    PETRU, F
    POPELA, B
    VESELA, Z
    METROLOGIA, 1992, 29 (04) : 301 - 307
  • [3] Absolute gravimeters: Status report on the use of iodine-stabilized He-Ne lasers at lambda approximate to 633 nm
    Chartier, JM
    Chartier, A
    Labot, J
    Winters, M
    METROLOGIA, 1995, 32 (03) : 181 - 184
  • [4] RUSSIAN-FINNISH COMPARISON OF THE FREQUENCIES OF IODINE-STABILIZED HE-NE LASERS AT 633 NM
    VITUSHKIN, LF
    ZAKHARENKO, YG
    MELNIKOV, NA
    HU, JP
    IKONEN, E
    RISKI, K
    METROLOGIA, 1994, 31 (01) : 33 - 34
  • [6] Experimental investigation of the power shift of iodine-stabilized He-Ne lasers at 633 nm
    Hu, J
    Ikonen, E
    Riski, K
    METROLOGIA, 1996, 33 (05) : 467 - 473
  • [7] IODINE-STABILIZED 543 NM HENE LASERS
    LIN, TS
    LIU, YW
    CHENG, WY
    SHY, JT
    JIH, BR
    KO, KL
    OPTICS COMMUNICATIONS, 1994, 107 (5-6) : 389 - 394
  • [8] Frequency comparison of iodine-stabilized he-ne lasers at 633 nm from the IMGC and the IFA-IFTAR
    Bertinetto, F
    Cordiale, P
    Popescu, G
    METROLOGIA, 1996, 33 (06) : 565 - 567
  • [9] Absolute gravimeters: status report on the use of iodine-stabilized He-Ne lasers at λ 633 nm
    Chartier, J.-M., 1600, Bur Int des Poids et Mes, Sevres Cedex, France (32):
  • [10] New type of iodine-stabilized He-Ne laser at 633 nm
    Qian, Jin
    Liu, Zhong-You
    Zhang, Xiao-Ping
    Shi, Chun-Ying
    Liu, Xiu-Ying
    Wang, Han-Ping
    Cai, Shan
    Tan, Hui-Ping
    Jiliang Xuebao/Acta Metrologica Sinica, 2008, 29 (01): : 10 - 13