TANDEM MASS-SPECTROMETRIC ANALYSIS OF PEPTIDES AT THE FEMTOMOLE LEVEL

被引:14
|
作者
KENNY, PTM [1 ]
ORLANDO, R [1 ]
机构
[1] SUNTORY INST BIOORGAN RES,SHIMAMOTO,OSAKA 618,JAPAN
关键词
D O I
10.1021/ac00032a022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the sequential analysis of peptides by fast atom bombardment (FAB) tandem mass spectrometry (MS/MS), the principal obstacle to decreasing sample quantities was determined to be the signal-to-background ratio of the ionization/desorption process. By decreasing the background ion current, continuous-flow FAB allows complete analysis (both MS and MS/MS) to be performed on 25-75% less sample than required for a conventional FABMS/MS experiment alone. The combination of CF-FAB with array detection permitted sequential analysis of several peptides (900-2000 Da) at the 900 fmol to 5.8 pmol level, without interference from the background. These levels do not produce a molecular ion species easily discernible above the background in conventional FAB.
引用
收藏
页码:957 / 960
页数:4
相关论文
共 50 条
  • [21] STRUCTURE OF STABLE ACETALDEHYDE ADDUCTS OF PEPTIDES AND PROTEINS - RESULTS OF MASS-SPECTROMETRIC ANALYSIS
    GEORGE, RCS
    HOBERMAN, HD
    FEDERATION PROCEEDINGS, 1987, 46 (06) : 2153 - 2153
  • [22] MASS-SPECTROMETRIC ANALYSIS OF LARGE PEPTIDES SYNTHESIZED BY RECOMBINANT-DNA TECHNOLOGY
    RICHTER, WJ
    DOMON, B
    MUELLER, D
    RASCHDORF, F
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 192 : 52 - ANYL
  • [23] INTRAMOLECULAR [O-18] ISOTOPIC EXCHANGE IN THE GAS-PHASE OBSERVED DURING THE TANDEM MASS-SPECTROMETRIC ANALYSIS OF PEPTIDES
    BALLARD, KD
    GASKELL, SJ
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (01) : 64 - 71
  • [24] ANALYTICAL CHARACTERISTICS OF LASER MASS-SPECTROMETRIC ANALYSIS WITH TRACE LEVEL SAMPLING
    KOVALEV, ID
    LARIN, NV
    SUCHKOV, AI
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1984, 39 (07): : 946 - 952
  • [25] A robust approach for the analysis of peptides in the low femtomole range by capillary electrophoresis-tandem mass spectrometry
    Neusüss, C
    Pelzing, M
    Macht, M
    ELECTROPHORESIS, 2002, 23 (18) : 3149 - 3159
  • [26] MASS-SPECTROMETRIC ANALYSIS OF HISTAMINE DICHLOROHYDRATE
    SERGEEV, PV
    MANUSADZ.VG
    MULTANOV.MM
    VASENOVA, RM
    BIOKHIMIYA, 1973, 38 (05): : 987 - 990
  • [27] DIRECT MASS-SPECTROMETRIC ANALYSIS OF PHYTOPHARMACEUTICALS
    SCHULTZE, W
    LANGE, G
    ARCHIV DER PHARMAZIE, 1988, 321 (09) : 642 - 642
  • [28] MASS-SPECTROMETRIC ANALYSIS OF ARSENIC TRISULFIDE
    JANAI, M
    RUDMAN, PS
    MANDELBAUM, A
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 1978, 27 (01) : 67 - 73
  • [29] MASS-SPECTROMETRIC ANALYSIS OF NONEQUILIBRIUM AIRFLOWS
    MACDERMOTT, WN
    DIX, RE
    AIAA JOURNAL, 1972, 10 (04) : 494 - +
  • [30] THERMOSPRAY MASS-SPECTROMETRIC ANALYSIS OF PHENAZINES
    WATSON, D
    TAYLOR, GW
    WILSON, R
    COLE, PJ
    ROWE, C
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 17 (04): : 251 - 255