PULSE SHAPE-ANALYZER FOR THE MULTIPLE PHOSWICH DETECTOR ON THE LAPEX EXPERIMENT

被引:3
|
作者
FRONTERA, F
DALFIUME, D
POULSEN, JM
TAIOCCHI, GF
BASILI, A
SILVESTRI, S
机构
[1] TAKES SDF,BERGAMO,ITALY
[2] UNIV FERRARA,DIPARTIMENTO FIS,I-44100 FERRARA,ITALY
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 1993年 / 324卷 / 03期
关键词
D O I
10.1016/0168-9002(93)91065-U
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A simple high performance pulse shape analyzer has been developed for the astronomical hard X-ray (20-300 keV) experiment LAPEX. The telescope makes use of 16 phoswich detectors of NaI(Tl)/CsI(Na) scintillator crystals. The pulse shape analyzer is based on 16 pairs of shaping amplifiers - one pair for each detector - and one digital electronic chain for calculation of an amplitude ratio, the pulse shape parameter. We describe the mathematical basis of the pulse shape analyser and the functions of its main circuit blocks. Both laboratory and in-flight data demonstrating the good performance of the circuits are presented.
引用
收藏
页码:589 / 597
页数:9
相关论文
共 50 条
  • [41] PULSE SHAPE ANALYZER FOR FAST NEUTRON-GAMMA RAY DISCRIMINATION
    BRIENT, CE
    YOUNG, RL
    NELSON, CE
    NUCLEAR INSTRUMENTS & METHODS, 1972, 98 (02): : 329 - &
  • [42] INVESTIGATION OF PULSE SHAPE ANALYZERS FOR PHOSWICH DETECTORS IN SPACE-BORNE HARD X-RAY EXPERIMENTS
    BLEEKER, JAM
    OVERTOOM, JM
    NUCLEAR INSTRUMENTS & METHODS, 1979, 167 (03): : 505 - 513
  • [43] Pulse shape discrimination of charged particles with a silicon strip detector
    Lu, J
    Figuera, P
    Amorini, F
    Cardella, G
    DiPietro, A
    Musumarra, A
    Papa, M
    Papalardo, G
    Rizzo, F
    Tudisco, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (03): : 374 - 379
  • [44] PULSE SHAPE DISCRIMINATION IN CSI(TL) RECOIL PROTON DETECTOR
    HARIHAR, P
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (04): : 719 - 719
  • [45] The Neutron-Gamma Pulse Shape Discrimination of CLLB Detector
    Song, Ruiqiang
    Peng, Shuo
    Tong, Yufeng
    Wu, Qi
    Qian, Sen
    Wang, Zhigang
    Han, Jifeng
    26TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS, CHEP 2023, 2024, 295
  • [46] Pulse shape calculations for the MARS segmented gamma ray detector
    Marginean, Raluca
    UPB Scientific Bulletin, Series A: Applied Mathematics and Physics, 2009, 71 (02): : 75 - 84
  • [47] PULSE SHAPE CALCULATIONS FOR THE MARS SEGMENTED GAMMA RAY DETECTOR
    Marginean, Raluca
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2009, 71 (02): : 75 - 84
  • [48] ANALYSIS OF PULSE SHAPE IN A ″FOSFICH″ DETECTOR IN AN ELECTRON SPECTROMETER.
    Gusev, A.A.
    Lupenko, G.V.
    Pugacheva, G.I.
    Savenko, I.A.
    Instruments and Experimental Techniques (English Translation of Pribory I Tekhnika Eksperimenta), 1976, 19 (4 pt 1): : 1029 - 1030
  • [49] THE SUPER-NOVA NEUTRINO PULSE SHAPE IN THE SCINTILLATION DETECTOR
    SEIDOV, ZF
    ASTROPHYSICS AND SPACE SCIENCE, 1982, 81 (1-2) : 483 - 488
  • [50] FAST-NEUTRON POLARIMETER WITH CARBON ANALYZER AND PULSE-SHAPE DISCRIMINATION
    SHERWOOD, JE
    MCDANIEL, FD
    MCELLISTREM, MT
    NUCLEAR INSTRUMENTS & METHODS, 1973, 107 (02): : 317 - 320