A CAPILLARY CONCENTRATOR FOR AN X-RAY MICROPROBE

被引:16
|
作者
VOSS, KF
KIM, KH
STERN, EA
BROWN, FC
HEALD, SM
机构
[1] UNIV WASHINGTON, DEPT PHYS, FM-15, SEATTLE, WA 98195 USA
[2] PACIFIC NW LAB, RICHLAND, WA 99352 USA
关键词
D O I
10.1016/0168-9002(94)91915-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Capillary concentrators are examined analytically and by computer simulations for applications in third-generation synchrotron-radiation bean-dines. A comparison is made between them and focusing mirrors for producing a small spot of X rays. Both devices are achromatic and useful for experiments that require an X-ray microprobe which delivers X rays over a broad band of energies. It is shown that the capillary concentrator produces an order of magnitude more intensity than the focusing mirror for spots below micrometer dimensions. The simulations also show that the exact profile of the capillary is not important except for the region near the outlet.
引用
收藏
页码:390 / 396
页数:7
相关论文
共 50 条
  • [21] An x-ray method for determining the stress concentrator shape
    Savvinov, AS
    Petrov, PP
    INDUSTRIAL LABORATORY, 1996, 62 (03): : 158 - 160
  • [22] PROPERTIES OF AN IDEAL OPTICAL X-RAY CONCENTRATOR.
    Vinogradov, A.V.
    Tolstikhin, O.I.
    Soviet Physics - Lebedev Institute Reports (English Translation of Sbornik Kratkie Soobshcheniya p, 1985, (09): : 28 - 32
  • [23] An X-Ray Method for Determining the Stress Concentrator Shape
    Savvinov, A. S.
    Petrov, P. P.
    Industrial Laboratory (USSR) (English translation of Zavodskaya Laboratoriya), 1996, 62 (03):
  • [24] The nuclear microprobe as a complementary technique to X-ray microscopy
    Moretto, P
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 161 - 161
  • [25] The fluorescence x-ray microprobe at the Advanced Light Source
    Thompson, AC
    Chapman, K
    APPLICATIONS OF SYNCHROTRON RADIATION TECHNIQUES TO MATERIALS SCIENCE III, 1996, 437 : 113 - 118
  • [26] Development of a Soft X-ray Microprobe for Radiobiology Studies
    Appuhamilage, I. A.
    Adjei, D.
    Alatabi, S. S.
    Alnaimi, R.
    Michette, A.
    Pfauntsch, S.
    ACTA PHYSICA POLONICA A, 2014, 125 (04) : 882 - 885
  • [27] Monochromatizing X-ray concentrator (MONO-XC)
    Bzhaumikhov, AA
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 : 512 - 516
  • [28] The x-ray microprobe for studies of cellular radiation response
    Michette, AG
    Pfauntsch, SJ
    Folkard, M
    Michael, BD
    Schettino, G
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 159 - 162
  • [29] X-RAY MICROPROBE ANALYSIS OF OSTEON CEMENT LINES
    SCHAFFLER, MB
    BURR, DB
    FREDERICKSON, RG
    ANATOMICAL RECORD, 1985, 211 (03): : A168 - A169
  • [30] DEVELOPMENT OF TEST SPECIMEN FOR X-RAY MICROPROBE ANALYSIS
    MARZELLA, LL
    CHANG, SH
    PENDERGRASS, RE
    RESAU, J
    MERGNER, WJ
    JOURNAL OF CELL BIOLOGY, 1983, 97 (05): : A309 - A309