We have constructed two types of high-temperature superconducting (HTSC) bolometers, whose performance is essentially wavelength independent from lambda approximately 0.6 to 450 mum: The first is a microbridge, of dimensions 20 X 20 mum, and the second is a meander, covering a region of approximately 1 mm2. Both were fabricated by photolithography of a superconducting YBaCuO thin film on SrTiO3. The bolometers are current biased, and the ac voltage induced by the chopped radiation is measured using lock-in detection. Operating optimally in the vicinity of the transition temperature (90 K), the first bolometer shows responsivity S approximately 1 mV/(W/cm2), while the second gives S approximately 800 V/W. The response of the first bolometer for various chopping frequencies is basically S approximately 1/square-root f, which makes it usable at frequencies up to > 50 kHz, while the second bolometer has a chopping-frequency response that is basically S approximately 1/f, with a cutoff frequency near 0.01 Hz.
引用
收藏
页码:3855 / 3861
页数:7
相关论文
共 50 条
  • [21] YBACUO THIN-FILM DEPOSITION WITH IODINE PHOTODISSOCIATION LASER
    JELINEK, M
    MUSIL, J
    CHARVAT, A
    SIMA, V
    SIMECKOVA, M
    HEJTMANEK, J
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1990, 9 (11) : 1336 - 1337
  • [22] Radio Frequency Carbon Nanotube Thin-Film Bolometer
    Gasper, Michael R.
    Toonen, Ryan C.
    Hirsch, Samuel G.
    Ivill, Mathew P.
    Richter, Henning
    Sivarajan, Ramesh
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2017, 65 (09) : 3278 - 3284
  • [23] SEQUENTIAL DEPOSITION OF YBACUO THIN-FILM ON SAPPHIRE SUBSTRATES
    HASS, N
    DAI, U
    DEUTSCHER, G
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1991, 4 : S262 - S264
  • [24] THIN-FILM BOLOMETER FOR HIGH-FREQUENCY METROLOGY
    BRUNETTI, L
    SENSORS AND ACTUATORS A-PHYSICAL, 1992, 32 (1-3) : 423 - 427
  • [25] A THIN-FILM BOLOMETER USING POROUS SILICON TECHNOLOGY
    LANG, W
    STEINER, P
    SCHABER, U
    RICHTER, A
    SENSORS AND ACTUATORS A-PHYSICAL, 1994, 43 (1-3) : 185 - 187
  • [26] FLUORINATION OF AN EPITAXIAL YBACUO THIN-FILM WITH CONTROLLED OXYGEN VACANCIES
    PERRIN, C
    PENA, O
    MOKHTARI, M
    THIVET, C
    GUILLOUXVIRY, M
    PERRIN, A
    SERGENT, M
    JOURNAL OF ALLOYS AND COMPOUNDS, 1993, 195 (1-2) : 339 - 342
  • [27] IMPROVED RESPONSIVITY AND SENSITIVITY CHARACTERISTICS OF THIN-FILM BISMUTH BOLOMETER
    BLOCK, WH
    GADDY, OL
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1973, QE 9 (02) : 252 - 254
  • [28] XPS STUDY OF PB/YBACUO THIN-FILM TUNNEL CONTACT
    SARAPATKA, TJ
    MIKUSIK, P
    APPLIED SURFACE SCIENCE, 1993, 68 (01) : 35 - 40
  • [29] THIN-FILM RESISTANCE BOLOMETER IR DETECTORS .2.
    LIDDIARD, KC
    INFRARED PHYSICS, 1986, 26 (01): : 43 - 49
  • [30] ELECTRODYNAMIC ANALYSIS AND EXPERIMENTAL RESEARCH OF THIN-FILM BOLOMETER UNITS
    GARB, KL
    NIKOLAEV, PV
    FRIDBERG, PS
    YAKOVER, IM
    RADIOTEKHNIKA I ELEKTRONIKA, 1984, 29 (10): : 1917 - 1926