Seismic Analysis of the Cooling Water Pump for Nuclear Power Plant for the Seismic Load

被引:0
|
作者
Chung, Chul Sup
机构
关键词
Cut-off Frequency; Equivalent Stress; Modal Analysis; Seismic Analysis;
D O I
10.3795/KSME-A.2009.33.11.1239
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
To evaluate the structural integrity of the nuclear seismic category penetration cooling water pump under the seismic service conditions the seismic analysis was performed in accordance with IEEE-STD-344 code. The finite element computer program, ANSYS, Version 10.0, is used to perform both a mode frequency analysis and an equivalent static seismic analysis of the pump assembly. The mode frequency analysis results show the fundamental natural frequency is greater than 33 Hz and does not exist in seismic range, thus justifying the use of the static analysis. The stresses resulted from various loadings and their combinations are within the allowable limits specified in the above mentioned IEEE code. The results of the seismic evaluation fully satisfied the structural acceptance criteria of the IEEE code. Accordingly the structural integrity on the pump assembly was proved.
引用
收藏
页码:1239 / 1243
页数:5
相关论文
共 50 条
  • [21] Seismic and Structure Analysis of a Temporary Rack Construction in a Nuclear Power Plant
    Kim, Heung Tae
    Lee, Young Shin
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2011, 35 (10) : 1265 - 1271
  • [22] Study on an Automated Seismic Analysis Program for Nuclear Power Plant Equipment
    Lee, Sang Rok
    Kim, Sung Ryul
    Transactions of the Korean Society of Mechanical Engineers, A, 2024, 48 (12) : 839 - 846
  • [24] MODELING OF SLABS IN SEISMIC ANALYSIS OF NUCLEAR-POWER PLANT BUILDINGS
    PERUMALSWAMI, PR
    DALAL, JS
    NUCLEAR ENGINEERING AND DESIGN, 1978, 47 (01) : 135 - 143
  • [25] Seismic stability analysis on diversion dike for tianwan nuclear power plant
    Yu-Hao, Jin
    Jie, Zhao
    Gui-Xuan, Wang
    Electronic Journal of Geotechnical Engineering, 2015, 20 (16): : 6847 - 6857
  • [26] Anti-seismic stability analysis of entrance and high slope of water tunnel for a nuclear power plant
    Bai Guang-bin
    Zhao Jie
    Yi Jian
    ROCK AND SOIL MECHANICS, 2014, 35 : 488 - 494
  • [27] Anti-seismic stability analysis of entrance and high slope of water tunnel for a nuclear power plant
    Bai, Guang-Bin
    Zhao, Jie
    Yi, Jian
    Yantu Lixue/Rock and Soil Mechanics, 2014, 35 : 488 - 494
  • [28] Fault analysis and treatment of stator cooling water pump in a power plant
    Chen, Shuai
    Sun, Yu
    INTERNATIONAL CONFERENCE ON INTELLIGENT EQUIPMENT AND SPECIAL ROBOTS (ICIESR 2021), 2021, 12127
  • [29] Three-Dimensional Seismic Analysis and Safety Evaluation for Nuclear Pump of Nuclear Power Plant Based on the RCC-M Code
    Meng Jigang
    Yang Shuhua
    Wang Yuefang
    ADVANCES IN VIBRATION ENGINEERING, 2011, 10 (04): : 343 - 352
  • [30] Quantification method for nuclear power plant seismic risk
    Wang J.
    Lin M.
    Hedongli Gongcheng/Nuclear Power Engineering, 2016, 37 (03): : 51 - 53