BIOACCUMULATION AND MEASUREMENT OF COPPER AT AN ALGA-MODIFIED CARBON PASTE ELECTRODE

被引:104
|
作者
GARDEATORRESDEY, J [1 ]
DARNALL, D [1 ]
WANG, J [1 ]
机构
[1] NEW MEXICO STATE UNIV,DEPT CHEM,LAS CRUCES,NM 88003
关键词
D O I
10.1021/ac00152a018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:72 / 76
页数:5
相关论文
共 50 条
  • [21] Electrocatalytic Oxidation of Cisapride at Carbon Paste Electrode Modified with Copper Sulfide Nanostructures
    Karim-Nezhad, Ghasem
    Pashazadeh, Sara
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2016, 8 (02): : 169 - 183
  • [22] Voltammetric copper(II) determination with a montmorillonite-modified carbon paste electrode
    Institute of Geonics, Academy of, Sciences of Czech Republic,, Studertska 1768, 708 00 Ostrava, Czech Republic
    Fresenius J Anal Chem, 5-6 (692-695):
  • [23] BIOACCUMULATION AND VOLTAMMETRIC BEHAVIOR OF GOLD AT ALGA-CONTAINING CARBON PASTE ELECTRODES
    GARDEATORRESDEY, J
    DARNALL, D
    WANG, J
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 252 (01) : 197 - 208
  • [24] Accumulation and trace measurement of paraquat at kaolin-modified carbon paste electrode
    El Mhammedi, M. A.
    Achak, M.
    Bakasse, M.
    Bachirat, R.
    Chtaini, A.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2010, 30 (06): : 833 - 838
  • [25] Electrocatalytic measurement of methionine concentration with a carbon nanotube paste electrode modified with benzoylferrocene
    Beitollahi, Hadi
    Mohadesi, Alireza
    Ghorbani, Farzaneh
    Karimi Maleh, Hassan
    Baghayeri, Mehdi
    Hosseinzadeh, Rahman
    CHINESE JOURNAL OF CATALYSIS, 2013, 34 (07) : 1333 - 1338
  • [26] Measurement of Dissolved Oxygen in Biological Fluids by Using a Modified Carbon Paste Electrode
    Jalali, Fahimeh
    Ashrafi, Amir M.
    Nematollahi, Davood
    ELECTROANALYSIS, 2009, 21 (02) : 201 - 205
  • [27] Copper phthalocyanine modified carbon paste electrode for simultaneous electrochemical analysis of homocysteine and cysteine
    Smith, Chip
    Garrison, Kenneth E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241
  • [28] Linear Scan Stripping Voltammetry of Copper(II) at the Chemically Modified Carbon Paste Electrode
    Department of Chemistry, Hangzhou University, Hangzhou 310028, China
    Mikrochim. Acta, 1-2 (125-132):
  • [29] Sensitive detection for nicotine using nickel/copper nanoparticle–modified carbon paste electrode
    M. Zaki
    Ezz El Shafie
    Soha A. Abdel-Gawad
    Amany M. Fekry
    M. Shehata
    Ionics, 2022, 28 : 4881 - 4891
  • [30] THE ZEOLITE-MODIFIED CARBON PASTE ELECTRODE
    ELMURR, N
    KERKENI, M
    SELLAMI, A
    BENTAARIT, Y
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 246 (02): : 461 - 465