BACKGROUND RECOGNITION IN GERMANIUM DETECTORS BY PULSE-SHAPE ANALYSIS

被引:0
|
作者
PETRY, F [1 ]
机构
[1] MAX PLANCK INST KERNPHYS, D-69029 HEIDELBERG, GERMANY
关键词
D O I
10.1016/0920-5632(94)90287-9
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
A method of event identification that distinguishes single and multiple events by determining the number of interactions in a high purity germanium detector is presented. The selectivity of the method has been experimentally verified.
引用
收藏
页码:391 / 393
页数:3
相关论文
共 50 条
  • [21] Spatial resolution attainable in germanium detectors by pulse shape analysis
    Blair, J
    Beckedahl, D
    Kammeraad, J
    Schmid, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 331 - 336
  • [22] First application of pulse-shape analysis to silicon micro-strip detectors
    von Schmid, M.
    Egelhof, P.
    Eremin, V.
    Gernhaeuser, R.
    Kroell, T.
    Mutterer, M.
    Pietralla, N.
    Streicher, B.
    Weber, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 629 (01): : 197 - 201
  • [23] PULSE SHAPE-DISCRIMINATION FOR BACKGROUND REJECTION IN GERMANIUM GAMMA-RAY DETECTORS
    FEFFER, PT
    SMITH, DM
    CAMPBELL, RD
    PRIMBSCH, JH
    LIN, RP
    LUKE, PN
    MADDEN, NW
    PEHL, RH
    MATTESON, JL
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY AND ATOMIC PHYSICS, 1989, 1159 : 287 - 294
  • [24] Breakthrough in pulse-shape based particle identification with silicon detectors
    Mutterer, M
    Trzaska, WH
    Tyurin, GP
    Evsenin, AV
    von Kalben, J
    Kemmer, J
    Kapusta, M
    Lyapin, VG
    Khlebnikov, SV
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 756 - 759
  • [25] Breakthrough in pulse-shape based particle identification with silicon detectors
    Mutterer, M
    Trzaska, WH
    Tyurin, GP
    Evsenin, AV
    von Kalben, J
    Kemmer, J
    Kapusta, M
    Lyapin, VG
    Khlebnikov, SV
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 148 - 151
  • [26] Distance metrics for digital pulse-shape discrimination of scintillator detectors
    Alharbi, T.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 156 : 205 - 209
  • [27] Breakthrough in pulse-shape based particle identification with silicon detectors
    Mutterer, M.
    Trzaska, W.H.
    Tyurin, G.P.
    Evsenin, A.V.
    von Kalben, J.
    Kemmer, J.
    Kapusta, M.
    Lyapin, V.G.
    Khlebnikov, S.V.
    IEEE Transactions on Nuclear Science, 2000, 47 (3 II) : 756 - 759
  • [28] Wilcoxon signed-rank-based technique for the pulse-shape analysis of HPGe detectors
    Martin, S.
    Quintana, B.
    Barrientos, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 823 : 32 - 40
  • [29] BACKGROUND REDUCTION AND NOISE DISCRIMINATION IN PROPORTIONAL COUNTING OF TRITIUM USING PULSE-SHAPE ANALYSIS
    HOCHEL, RC
    HAYES, DW
    NUCLEAR INSTRUMENTS & METHODS, 1975, 130 (01): : 183 - 188
  • [30] Limitations of the pulse-shape technique for particle discrimination in planar Si detectors
    Pausch, G
    Moszynski, M
    Bohne, W
    Cederkall, J
    Grawe, H
    Klamra, W
    Lampert, MO
    Rohr, P
    Schubart, R
    Seidel, W
    Wolski, D
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 687 - 691