BACKGROUND RECOGNITION IN GERMANIUM DETECTORS BY PULSE-SHAPE ANALYSIS

被引:0
|
作者
PETRY, F [1 ]
机构
[1] MAX PLANCK INST KERNPHYS, D-69029 HEIDELBERG, GERMANY
关键词
D O I
10.1016/0920-5632(94)90287-9
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
A method of event identification that distinguishes single and multiple events by determining the number of interactions in a high purity germanium detector is presented. The selectivity of the method has been experimentally verified.
引用
收藏
页码:391 / 393
页数:3
相关论文
共 50 条
  • [1] BACKGROUND RECOGNITION IN GERMANIUM DETECTORS BY PULSE-SHAPE ANALYSIS
    PETRY, F
    PROGRESS IN PARTICLE AND NUCLEAR PHYSICS, VOL 32: NEUTRINOS IN COSMOLOGY, ASTRO, PARTICLE AND NUCLEAR PHYSICS, 1994, 32 : 281 - 283
  • [2] BACKGROUND RECOGNITION IN GE DETECTORS BY PULSE-SHAPE ANALYSIS
    PETRY, F
    PIEPKE, A
    STRECKER, H
    KLAPDORKLEINGROTHAUS, HV
    BALYSH, A
    BELYAEV, ST
    DEMEHIN, A
    GUROV, A
    KONDRATENKO, I
    KOTELNIKOV, D
    LEBEDEV, VI
    LANDIS, D
    MADDEN, N
    PEHL, RH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 332 (1-2): : 107 - 112
  • [3] PULSE-SHAPE ANALYSIS FOR GERMANIUM DETECTORS USED IN DM SEARCHES
    SAGDEEV, IR
    DRUKIER, AK
    WELSH, DJ
    KLIMENKO, AA
    OSETROV, SB
    SMOLNIKOV, AA
    NUCLEAR PHYSICS B, 1994, : 175 - 179
  • [4] Pulse-shape analysis of ionization events in low-temperature germanium detectors
    Broniatowski, A
    Juillard, A
    Bergé, L
    Dumoulin, L
    LOW TEMPERATURE DETECTORS, 2002, 605 : 521 - 524
  • [5] Pulse-shape discrimination techniques for correcting the effects of radiation damage in germanium coaxial detectors
    Ho, W.C.G.
    Boggs, S.E.
    Lin, R.P.
    Slassi-Sennou, S.
    Madden, N.W.
    Pehl, R.H.
    Hull, E.L.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 412 (2-3): : 507 - 514
  • [6] Pulse-shape discrimination techniques for correcting the effects of radiation damage in germanium coaxial detectors
    Ho, WCG
    Boggs, SE
    Lin, RP
    Slassi-Sennou, S
    Madden, NW
    Pehl, RH
    Hull, EL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 412 (2-3): : 507 - 514
  • [7] Pulse-shape analysis for gamma background rejection in thermal neutron radiation using CVD diamond detectors
    Kavrigin, P.
    Finocchiaro, P.
    Griesmayer, E.
    Jericha, E.
    Pappalardo, A.
    Weiss, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 795 : 88 - 91
  • [8] PULSE-SHAPE DISCRIMINATION WITH SURFACE BARRIER DETECTORS
    EMMERICH, WD
    FRANK, K
    HOFMANN, A
    DITTNER, A
    KLEIN, JW
    STOCK, R
    NUCLEAR INSTRUMENTS & METHODS, 1970, 83 (01): : 131 - &
  • [9] Digital pulse-shape processing for CdTe detectors
    Bargholtz, C
    Fumero, E
    Mårtensson, L
    Wachtmeister, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 290 - 292
  • [10] Pulse shape and segmentation analysis in germanium detectors for ββ decay
    Gehman, V. M.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2012, 221 : 346 - 346