UHV PHOTOELECTRON X-RAY-BEAM POSITION MONITOR

被引:9
|
作者
JOHNSON, ED
OVERSLUIZEN, T
机构
[1] Brookhaven National Laboratory, National Synchrotron Light Source, Upton
基金
美国能源部;
关键词
D O I
10.1016/0168-9002(90)90099-R
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
As part of our research program to develop viable beam position monitors for both the X-ray and the VUV beamlines at the NSLS, we have constructed vertical photon beam position monitors which are presently mounted in two front-end tanks in the X-ray ring. These area-type detectors are located before the safety shutters and are, therefore, able to monitor the beam position even during injection. The features of this type of monitor which contribute to its long-term stability, position sensitivity, and immunity to horizontal beam motion have been examined and are discussed. © 1990.
引用
收藏
页码:427 / 430
页数:4
相关论文
共 50 条
  • [41] PRIMARY SPECTRUM ANALYSIS OF A 6-MV X-RAY-BEAM
    DEWYNGAERT, JK
    HUANG, PH
    KASE, KR
    MEDICAL PHYSICS, 1983, 10 (04) : 545 - 545
  • [42] NEW BEAM POSITION MONITOR FOR X-RAY SYNCHROTRON RADIATION FACILITIES.
    Stefan, P.M.
    Siddons, D.P.
    Hastings, J.B.
    Nuclear instruments and methods in physics research, 1987, A255 (03): : 598 - 602
  • [43] Residual gas x-ray beam position monitor development for PETRA III
    Ilinski, P.
    Hahn, U.
    Schulte-Schrepping, H.
    Degenhardt, M.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 782 - +
  • [44] Design updates of the x-ray beam position monitor for beamline front ends
    Shu, Deming
    Singh, Om
    Hahne, Michael
    Decker, Glenn
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1014 - +
  • [45] NOISE FACTOR OF A POLYENERGETIC X-RAY-BEAM IN COMPUTED-TOMOGRAPHY
    MORGENTHALER, DG
    BROOKS, RA
    TALBERT, AJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (02): : 251 - 259
  • [46] THE POLARIZATION FACTOR FOR A REPEATEDLY REFLECTED X-RAY-BEAM - SPECIAL CASES
    VINCENT, MG
    ACTA CRYSTALLOGRAPHICA SECTION A, 1982, 38 (JUL): : 510 - 512
  • [47] ACCOUNTING FOR PRIMARY ELECTRON SCATTER IN X-RAY-BEAM CONVOLUTION CALCULATIONS
    KEALL, P
    HOBAN, P
    MEDICAL PHYSICS, 1995, 22 (09) : 1413 - 1418
  • [48] A SEMIANALYTICAL METHOD FOR THE DESIGN OF A LINAC X-RAY-BEAM FLATTENING FILTER
    FLOCK, ST
    SHRAGGE, PC
    MEDICAL PHYSICS, 1987, 14 (02) : 202 - 209
  • [49] DIFFRACTION OF A FOCUSED X-RAY-BEAM BY SURFACE ACOUSTIC-WAVES
    TUCOULOU, R
    SCHELOKOV, IA
    ROSHCHUPKIN, DV
    BRUNEL, M
    ORTEGA, L
    CHEVALLIER, P
    OPTICS COMMUNICATIONS, 1995, 118 (3-4) : 175 - 180
  • [50] TIME MODULATION OF AN X-RAY-BEAM BY SURFACE ACOUSTIC-WAVES
    ROSHCHUPKIN, DV
    BRUNEL, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02): : 379 - 382