摘要
The thickness of silicon dioxide on polycrystalline silicon is measured using ultraviolet (UV) ellipsometry (with a quartz halogen light source with wavelength 4050 angstrom). The UV allows the problem to be treated as a single film on a bulk material, and hence greatly simplifies the calculation. Two applications of oxide growth on polycrystalline silicon as sacrificial and nonsacrificial etch masking layers are used to illustrate the method. Initial oxide thickness and oxide losses after relevant post-processing were measured for 1.8, 4, and 8 kangstrom of boron doped polysilicon. Although the effect of reactive ion etching (RIE) damage on ellipsometric parameters has been reported previously for single crystal silicon, we report the first optical evidence of RIE damage to polycrystalline silicon.
引用
收藏
页码:1772 / 1777
页数:6
相关论文
共 50 条
  • [21] Influence of Polysilicon Thickness on Properties of Screen-Printed Silver Paste Metallized Silicon Oxide/Polysilicon Passivated Contacts
    Chaudhary, Aditya
    Hoss, Jan
    Lossen, Jan
    Huster, Frank
    Kopecek, Radovan
    van Swaaij, Rene
    Zeman, Miro
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2021, 218 (18):
  • [22] Sub-nanometer scale measurements of silicon oxide thickness by spectroscopic ellipsometry
    Gonda, S
    Tanaka, M
    Kurosawa, T
    Kojima, I
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1998, 37 (11B): : L1418 - L1420
  • [23] Ellipsometry measurement accuracy of gate oxides under polysilicon
    Jiang, G
    Pelcher, D
    Kwon, D
    Clerico, J
    Collins, G
    MICRO- AND NANOSYSTEMS, 2004, 782 : 147 - 152
  • [24] A NOVEL TRENCH PLANARIZATION TECHNIQUE USING POLYSILICON REFILL, POLYSILICON OXIDATION, AND OXIDE ETCHBACK
    SHENAI, K
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1993, 40 (02) : 459 - 463
  • [25] EFFECT OF WEAR OF MAGNETIC MEDIA ON LUBRICANT THICKNESS USING ELLIPSOMETRY
    HU, Y
    TALKE, FE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 227 - POLY
  • [26] SIMULTANEOUS SILICON-WAFER TEMPERATURE AND OXIDE FILM THICKNESS MEASUREMENT IN RAPID-THERMAL PROCESSING USING ELLIPSOMETRY
    SAMPSON, RK
    CONRAD, KA
    IRENE, EA
    MASSOUD, HZ
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1993, 140 (06) : 1734 - 1743
  • [27] Accurate determination of ultrathin gate oxide thickness and effective polysilicon doping of CMOS devices
    Gupta, A
    Fang, P
    Song, M
    Lin, MR
    Wollesen, D
    Chen, K
    Hu, CM
    IEEE ELECTRON DEVICE LETTERS, 1997, 18 (12) : 580 - 582
  • [28] ELLIPSOMETRY AND THICKNESS OF SURFACE LAYERS
    RUSANOV, AI
    PSHENITS.VI
    DOKLADY AKADEMII NAUK SSSR, 1969, 187 (03): : 619 - &
  • [29] Comparative study of surface roughness measured on polysilicon using spectroscopic ellipsometry and atomic force microscopy
    Friedrich-Alexander-Universitaet, Erlangen-Nuernberg, Erlangen, Germany
    Thin Solid Films, 1-2 (186-191):
  • [30] Non-destructive measurement of foot/notch on etched polysilicon gates using Spectroscopic Ellipsometry
    Hodges, JS
    Peters, RM
    ISSM 2005: IEEE International Symposium on Semiconductor Manufacturing, Conference Proceedings, 2005, : 406 - 409