THE VALUE OF DIGITAL RADIOGRAPHY SYSTEMS IN SKELETAL IMAGING

被引:8
|
作者
LEHMANN, KJ
BUSCH, HP
SOMMER, A
GEORGI, M
机构
关键词
DIGITAL IMAGE INTENSIFIER RADIOGRAPHY; DIGITAL STORAGE PHOSPHOR RADIOGRAPHY; DIGITAL SKELETAL IMAGING; 100 MM TECHNIQUE; FROC-STUDY; SPATIAL RESOLUTION; ENTRANCE DOSE;
D O I
10.1055/s-2008-1033134
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The clinical value and the imaging characteristics of digital radiography systems (image intensifier (I. I.) radiography: Polytron/Siemens, storage phosphor radiography: PCR/Philipps) in skeletal imaging were compared with film-screen radiography and 100 mm technique. The influence of spatial and contrast resolution, entrance dose and detectability of lytic, osteoblastic and cortical lesions were studied as well as the images of 25 parallel examined patients. Only with the small image intensifier (diameter 14 cm) the quality of 100 mm technique and digital I.I. radiography was equivalent to storage phosphor and film-screen radiography. Storage phosphor radiography seems to be better qualified than I.I. radiography to replace conventional techniques in skeletal imaging.
引用
收藏
页码:286 / 291
页数:6
相关论文
共 50 条
  • [31] Finger Imaging by RadioVisioGraphy Digital Dental Radiography Imaging System
    Harikrishnan, Pandurangan
    JOURNAL OF HAND AND MICROSURGERY, 2016, 8 (03) : 181 - 182
  • [32] INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .10. STRUCTURE MOTTLE OF II-TV DIGITAL IMAGING-SYSTEMS
    KUME, Y
    DOI, K
    OHARA, K
    GIGER, ML
    MEDICAL PHYSICS, 1986, 13 (06) : 843 - 849
  • [33] ADAPTIVE HISTOGRAM EQUALIZATION IN DIGITAL RADIOGRAPHY OF DESTRUCTIVE SKELETAL LESIONS
    BRAUNSTEIN, EM
    CAPEK, P
    BUCKWALTER, K
    BLAND, P
    MEYER, CR
    RADIOLOGY, 1988, 166 (03) : 883 - 885
  • [34] ADAPTIVE HISTOGRAM EQUALIZATION IN DIGITAL RADIOGRAPHY OF DESTRUCTIVE SKELETAL LESIONS
    CAPEK, P
    BRAUNSTEIN, EM
    BUCKWALTER, K
    BLAND, P
    MEYER, CR
    INVESTIGATIVE RADIOLOGY, 1988, 23 (09) : S35 - S35
  • [35] Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging
    Liu, Xinming
    Shaw, Chris C.
    Lai, Chao-Jen
    Wang, Tianpeng
    MEDICAL PHYSICS, 2011, 38 (01) : 23 - 33
  • [36] INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .7. NOISE WIENER SPECTRA OF II-TV DIGITAL IMAGING-SYSTEMS
    GIGER, ML
    DOI, K
    FUJITA, H
    MEDICAL PHYSICS, 1986, 13 (02) : 131 - 138
  • [37] Investigation of noise sources for digital radiography systems
    Ergun L.
    Olgar T.
    Radiological Physics and Technology, 2017, 10 (2) : 171 - 179
  • [38] Comparison of two digital intraoral radiography imaging systems as a function of contrast resolution and exposure time
    Aydin, Kader C.
    Demirel, Oguzhan
    Ozcan, Mutlu
    MINERVA STOMATOLOGICA, 2020, 69 (03): : 148 - 152
  • [39] Matched filtering of images in digital radiography systems
    Udod, VA
    Temnik, AK
    Solodushkin, VV
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 1999, 35 (11) : 863 - 867
  • [40] Quality assurance of computed and digital radiography systems
    Walsh, C.
    Gorman, D.
    Byrne, P.
    Larkin, A.
    Dowling, A.
    Malone, J. F.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 271 - 275