iCub whole-body control through force regulation on rigid non-coplanar contacts

被引:52
|
作者
Noril, Francesco [1 ]
Traversarol, Silvio [1 ]
Eljaikl, Jorhabib [1 ]
Romano, Francesco [1 ]
Del Prete, Andrea [2 ]
Pucci, Daniele [1 ]
机构
[1] Fondazione Ist Italiano Tecnol, Cognit Humanoids Lab, Dept Robot Brain & Cognit Sci, Via Morego 30, I-16163 Genoa, Italy
[2] Univ Toulouse, CNRS, LAAS, Toulouse, France
关键词
whole-body control; floating-base robots; rigid contacts; non-coplanar contact; tactile sensors; force sensors;
D O I
10.3389/frobt.2015.00006
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
This paper details the implementation of state-of-the-art whole-body control algorithms on the humanoid robot iCub. We regulate the forces between the robot and its surrounding environment to stabilize a desired posture. We assume that the forces and torques are exerted on rigid contacts. The validity of this assumption is guaranteed by constraining the contact forces and torques, e.g., the contact forces must belong to the associated friction cones. The implementation of this control strategy requires the estimation of both joint torques and external forces acting on the robot. We then detail algorithms to obtain these estimates when using a robot with an iCub-like sensor set, i.e., distributed six-axis force-torque sensors and whole-body tactile sensors. A general theory for identifying the robot inertial parameters is also presented. From an actuation standpoint, we show how to implement a joint-torque control in the case of DC brushless motors. In addition, the coupling mechanism of the iCub torso is investigated. The soundness of the entire control architecture is validated in a real scenario involving the robot iCub balancing and making contact with both arms.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] A performance study for whole-body helicoidal CT/PET-FDG a posteriori registration using rigid and non-rigid FFD-based methods.
    Delzescaux, T
    Foehrenbach, H
    Frouin, V
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 60P - 60P
  • [42] An accurate 3D shape context based non-rigid registration method for mouse whole-body skeleton registration
    Xiao, Di
    Zahra, David
    Bourgeat, Pierrick
    Berghofer, Paula
    Tamayo, Oscar Acosta
    Wimberley, Catriona
    Gregoire, Marie Claude
    Salvado, Olivier
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [43] ;Wheelchair Support by a Humanoid Through Integrating Environment Recognition, Whole-body Control and Human-Interface Behind the User
    Nozawa, Shunichi
    Maki, Toshiaki
    Kojima, Mitsuharu
    Kanzaki, Shigeru
    Okada, Kei
    Inaba, Masayuki
    2008 IEEE/RSJ INTERNATIONAL CONFERENCE ON ROBOTS AND INTELLIGENT SYSTEMS, VOLS 1-3, CONFERENCE PROCEEDINGS, 2008, : 1558 - 1563
  • [44] Whole-body Control of Non-holonomic Mobile Manipulator Based on Hierarchical Quadratic Programming and Continuous Task Transition
    Kim, Sanghyun
    Jang, Keunwoo
    Park, Suhan
    Lee, Yisoo
    Lee, Sang Yup
    Park, Jaeheung
    2019 IEEE 4TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS AND MECHATRONICS (ICARM 2019), 2019, : 414 - 419
  • [45] Non-rigid anatomical standardization of whole-body PET/CT identifies variation of FDG distribution with age and sex: an AI-assisted study
    Hirata, K.
    Watanabe, S.
    Takenaka, J.
    Wakabayashi, N.
    Kimura, R.
    Nagai, T.
    Ogawa, T.
    Kudo, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S347 - S348
  • [46] Involvement of non-neuronal brain cells in AVP-mediated regulation of water space at the cellular, organ, and whole-body level
    Hertz, L
    Chen, Y
    Spatz, M
    JOURNAL OF NEUROSCIENCE RESEARCH, 2000, 62 (04) : 480 - 490
  • [47] COMPARATIVE EFFECTS OF WHOLE-BODY VIBRATION ON SENSORIMOTOR PERFORMANCE ACHIEVED WITH A MINI-STICK AND A MACRO-STICK IN FORCE AND POSITION CONTROL MODES
    RIBOT, E
    ROLL, JP
    GAUTHIER, GM
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1986, 57 (08): : 792 - 799
  • [48] On the passive shimming of a 7 T whole-body MRI superconducting magnet: Implementation with minimized ferromagnetic materials usage and operable magnetic force control
    Wang, Wenchen
    Wang, Yaohui
    Wang, Hui
    Cheng, Junsheng
    Qu, Hongyi
    Wang, Cong
    Niu, Chaoqun
    Liu, Feng
    MEDICAL PHYSICS, 2023, 50 (10) : 6514 - 6524
  • [49] Whole-body continuous-bed-motion PET list-mode reconstruction with non-rigid event-by-event respiratory motion correction
    Lu, Yihuan
    Fontaine, Kathryn
    Gallezot, Jean-Dominique
    Mulnix, Tim
    Panin, Vladimir
    Jones, Judson
    Casey, Michael
    Carson, Richard
    Liu, Chi
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [50] Task-based whole-body control of humanoid robots with ZMP regulation, real-time application to a squat-like motion
    Galdeano, David
    Chemori, Ahmed
    Krut, Sebastien
    Fraisse, Philippe
    2014 11TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2014,