QUALITY ASSURANCE IN THE CHART CLINICAL-TRIAL

被引:19
|
作者
AIRD, EGA
WILLIAMS, C
MOTT, GTM
DISCHE, S
SAUNDERS, MI
机构
[1] Marie Curie Research Wing for Oncology, Mount Vernon Hospital, Northwood, Middlesex HA6 2RN, Rickmansworth Road
关键词
CHART; QUALITY ASSURANCE; TOLERANCE; PHANTOM MEASURES;
D O I
10.1016/0167-8140(95)01598-B
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
As part of the clinical trial of CHART (continuous hyperfractionated accelerated radiotherapy) a quality assurance programme was included. The technical part of this - which is reported in this paper - is a series of tests designed to check all aspects of treatment planning and delivery. The results of visits to the 13 participating centres - and repeat visits to some of these centres - are discussed. The main areas tested were as follows. The linear accelerator: mechanical, and optical, scales and indicators; radiation field size; flatness and symmetry. Dosimetry: output; wedge factor; beam energy; phantom measurements against a plan calculated by the centre. Simulator: mechanical, optical scales and indicators. The results show these centres work within the tolerances chosen for most parameters. Flatness, wedge factor and energy were areas of weakness in some centres. This must be partly the cause of the spread of phantom measurements which, after removal of variations in output, still range from -7 to +6% between calculated and measured values.
引用
收藏
页码:235 / 244
页数:10
相关论文
共 50 条
  • [31] CLINICAL-TRIAL METHODOLOGY
    PETO, R
    BIOMEDICINE, 1978, 28 : 24 - 36
  • [32] CLINICAL-TRIAL METHODOLOGY
    PETO, R
    NATURE, 1978, 272 (5648) : 15 - 16
  • [33] DESIGNING A CLINICAL-TRIAL
    MIRAKHUR, RK
    BAILLIERES CLINICAL ANAESTHESIOLOGY, 1988, 2 (01): : 157 - 174
  • [34] CLINICAL-TRIAL OF RHINIPAN
    LUTOLF, U
    UTHEMANN, B
    SCHWEIZERISCHE RUNDSCHAU FUR MEDIZIN PRAXIS, 1978, 67 (35): : 1285 - 1287
  • [35] THE RANDOMIZED CLINICAL-TRIAL
    BUDSBERG, SC
    VETERINARY SURGERY, 1991, 20 (05) : 326 - 328
  • [36] CONTROLLED CLINICAL-TRIAL
    DOYON, F
    HILL, C
    MEDECINE ET MALADIES INFECTIEUSES, 1984, 14 (12): : 708 - 713
  • [37] COMPARISON OF QUALITY-OF-LIFE INSTRUMENTS IN A CANCER CLINICAL-TRIAL
    LEVINE, M
    GUYATT, G
    DEPAUW, S
    CLINICAL RESEARCH, 1987, 35 (03): : A353 - A353
  • [38] A TURNKEY SYSTEM FOR CLINICAL-TRIAL DATA QUALITY-CONTROL
    MAJOR, R
    CONTROLLED CLINICAL TRIALS, 1986, 7 (03): : 228 - 228
  • [39] COMPARISON OF QUALITY-OF-LIFE INSTRUMENTS IN A SETTING OF A CLINICAL-TRIAL
    DEPAUW, S
    LEVINE, M
    GUYATT, G
    CONTROLLED CLINICAL TRIALS, 1987, 8 (03): : 293 - 294
  • [40] A CLINICAL-TRIAL WITH DSIP
    KAESER, HE
    EUROPEAN NEUROLOGY, 1984, 23 (05) : 386 - 388