Simulation Study on the Cooling Performance of the Two-Stage Compression CO2 Cycle with the a Flash Intercooler and Flash Gas Bypass

被引:0
|
作者
Kwak, Myoung Seok [1 ]
Cho, Honghyun [1 ]
机构
[1] Chosun Univ, Dept Mech Engn, Gwangju, South Korea
关键词
Two-Stage Compression Cycle(2); COP; Carbon Dioxide; Intercooler;
D O I
10.3795/KSME-B.2012.36.1.017
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
There has been little study on the performance characteristics of the effective heat pump systems in the cooling mode using the two-stage compression cycles have hardly performed. In this study, the performance of the two-stage compression CO2 cycle with an FI (flash intercooler) and the FGB (flash gas bypass) was investigated by using a theoretical method. The performance analysis was carried out with aby varyingiation( the indoor temperature, outdoor temperature, and 1st- and 2nd-stage EEV openings. As of a result, the coefficients of performance (COPs) of the Bbasic, FI, and FGB cycles were decreased by 28.5%, 22.1%, and 24.5%, respectively, for various outdoor temperature conditions. In addition to, the performance variation of the two-stage compression cycle was smaller than that of the single-stage compression cycle. The performance of the FI and FGB cycles was improved by 13.5%, and 6.9% respectively, when the 1st-stage EEV opening was increased from 32% to 48%, and by 0.9%, and 2.6%, respectively, when the 1st- and the 2nd-stage EEV opening was increased from 32% to 48%, and was increased from 42% to 58%, respectively. The FI cycle showed an the most improved performance for any given operating conditions.
引用
收藏
页码:17 / 24
页数:8
相关论文
共 50 条
  • [31] An optimisation study on a real-world transcritical CO2 heat pump system with a flash gas bypass
    Wang, Ji
    Belusko, Martin
    Semsarilar, Hesam
    Evans, Michael
    Liu, Ming
    Bruno, Frank
    ENERGY CONVERSION AND MANAGEMENT, 2022, 251
  • [32] Thermodynamic analysis of double-compression flash intercooling transcritical CO2 refrigeration cycle
    Zhang, Zhenying
    Wang, Hongli
    Tian, Lili
    Huang, Chunsong
    JOURNAL OF SUPERCRITICAL FLUIDS, 2016, 109 : 100 - 108
  • [33] Thermodynamic performance and the exergy destruction of the transcritical CO2 two-stage compression and ejector expansion direct cooling ice making system
    Li, Wenlong
    Wang, Baodong
    Deng, Jianqiang
    He, Yang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 151 : 314 - 330
  • [34] Study on compression stage in two-stage light gas gun
    Wu, Jing
    Lan, Qiang
    Wang, Qing-Song
    Xian, Hai-Feng
    Jia, Lu-Feng
    Fu, Qiu-Wei
    Gaoya Wuli Xuebao/Chinese Journal of High Pressure Physics, 2006, 20 (04): : 445 - 448
  • [35] Studies on a two-stage transcritical carbon dioxide heat pump cycle with flash intercooling
    Agrawal, Neeraj
    Bhattacharyya, Souvik
    APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) : 299 - 305
  • [36] A Gas-Steam Combined Cycle System with CO2 Capture by Integrating Two-Stage MCFC
    Duan, Liqiang
    Zhu, Jingnan
    Yang, Yongping
    PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON ENERGY, 2013, : 309 - 314
  • [37] Performance Analysis and Optimization of Supercritical CO2 Recompression Brayton Cycle Coupled With Organic Flash Cycle With a Two-Phase Expander
    Yu, Tingfang
    Zhang, Genli
    Zhou, Jiapeng
    Tang, Yicun
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (11)
  • [38] Performance of a new two-stage multi-intercooling transcritical CO2 ejector refrigeration cycle
    Manjili, F. Eskandari
    Yavari, M. A.
    APPLIED THERMAL ENGINEERING, 2012, 40 : 202 - 209
  • [39] Performance improvement of a transcritical CO2 refrigeration cycle using two-stage thermoelectric modules in sub-cooler and gas cooler
    Jamali, Siamak
    Yari, Mortaza
    Mohammadkhani, Farzad
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 74 : 105 - 115
  • [40] Performance evaluation of flash tank-absorption cooling cycle using two ejectors
    Abed, Azher M.
    Alghoul, M. A.
    Sopian, K.
    APPLIED THERMAL ENGINEERING, 2016, 101 : 47 - 60