A 68-year-old man with recurrent attacks of monomorphic ventricular tachycardia [VT] received a pacer cardioverter defibrillator featuring antitachycardia pacing and cardioversion/defibrillation. Over 300 episodes of VT were successfully terminated by antitachycardia pacing. During Holter monitoring the patient experienced supraventricular tachycardia with delivery of multiple antitachycardia pacing, cardioversion, and defibrillation therapies ending with the death of the patient. The following factors played a role in the unfortunate outcome of this patient: 1. triggering of VT therapy by an unexpected high sinus rate; 2. atrial fibrillation induced by cardioversion therapy; 3. a gradual and continuous increase in rate during atrial fibrillation possibly caused by repeated VT and ventricular fibrillation therapies and/or by a thrombus, found at autopsy, in a bypass graft; and 4. the limited ability of presently available defibrillators to distinguish between ventricular and supraventricular arrhythmias.
引用
收藏
页码:1008 / 1014
页数:7
相关论文
共 50 条
  • [41] SUDDEN-DEATH
    VAISRUB, S
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1978, 239 (14): : 1425 - 1425
  • [42] SUDDEN-DEATH
    MAZUR, NA
    KLINICHESKAYA MEDITSINA, 1988, 66 (11): : 28 - 35
  • [43] SUDDEN CARDIAC DEATH DURING AMBULATORY HOLTER MONITORING - REPORT ON 3 DOCUMENTED CASES
    RETTIG, G
    SEN, S
    JAPANESE HEART JOURNAL, 1984, 25 (04): : 639 - 649
  • [44] ANGIOGRAPHIC FINDINGS IN SURVIVORS OF SUDDEN-DEATH AND CHARACTERISTICS OF RECURRENT SUDDEN-DEATH
    WEAVER, WD
    LORCH, GS
    ALVAREZ, H
    COBB, LA
    AMERICAN JOURNAL OF CARDIOLOGY, 1976, 37 (01): : 181 - 181
  • [45] TRANSVENOUS AUTOMATIC DEFIBRILLATOR FOR PREVENTION OF SUDDEN-DEATH FROM VENTRICULAR-FIBRILLATION
    MIROWSKI, M
    MOWER, MM
    GOTT, VL
    CHEST, 1974, 65 (05) : 594 - 594
  • [46] AMIODARONE DISTRIBUTION IN HUMAN-TISSUES AFTER SUDDEN-DEATH DURING HOLTER RECORDING
    MAGGIONI, AP
    MAGGI, A
    VOLPI, A
    DARANNO, V
    TOGNONI, G
    GIANI, P
    AMERICAN JOURNAL OF CARDIOLOGY, 1983, 52 (01): : 217 - 218
  • [47] PREVENTION OF SUDDEN-DEATH - A STRATEGY FOR THE SELECTIVE USE OF AMIODARONE AND THE AUTOMATIC IMPLANTABLE DEFIBRILLATOR
    FOGOROS, RN
    FIEDLER, SB
    ELSON, JJ
    CIRCULATION, 1985, 72 (04) : 385 - 385
  • [48] VERAPAMIL - A CAUSE OF SUDDEN-DEATH IN A PATIENT WITH HYPERTROPHIC CARDIOMYOPATHY
    PERROT, B
    DANCHIN, N
    DELACHAISE, AT
    BRITISH HEART JOURNAL, 1984, 51 (03): : 352 - 354
  • [49] THE AUTOMATIC IMPLANTABLE DEFIBRILLATOR - A PREVENTIVE TREATMENT OF SUDDEN-DEATH FROM VENTRICULAR ARRHYTHMIA
    LECLERCQ, JF
    MENASCHE, P
    PIWNICA, A
    COUMEL, P
    SLAMA, R
    PRESSE MEDICALE, 1983, 12 (27): : 1707 - 1710
  • [50] CIRCADIAN VARIATION IN RECURRENT SUDDEN-DEATH ABORTED BY DISCHARGES FROM THE IMPLANTABLE DEFIBRILLATOR
    DAVILA, A
    GEBARA, O
    BRUGADA, P
    CIRCULATION, 1993, 88 (04) : 155 - 155