COMPARISON BETWEEN STANDARD FRACTURE-TOUGHNESS RESULTS AND SURFACE FLAW DATA FOR SILICON-CARBIDE

被引:0
|
作者
REUTER, WG
EPSTEIN, JS
HAGGAG, FM
机构
[1] GEORGIA TECH UNIV,DEPT CIVIL ENGN,ATLANTA,GA 30332
[2] OAK RIDGE NATL LAB,OAK RIDGE,TN 37830
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Stress intensity factors were measured for single-edge notched silicon carbide specimens subjected to three-point bending. These data are compared with experimental results from surface flawed specimens subjected to three-point bending. Surface flawed specimens were tested since they resemble defects in structures more closely than any other specimen. The ability to estimate failure conditions for a structural component using measurements of fracture toughness and appropriate equations was evaluated. In many of these tests, acoustic emission and moire interferometry techniques provided valuable information on the crack growth process, constitutive damage zone propagation, and the critical stress intensity factors.
引用
收藏
页码:181 / 200
页数:20
相关论文
共 50 条
  • [42] Randomized intravascular ultrasound comparison between patients that underwent amorphous hydrogenated silicon-carbide coated stent deployment versus uncoated stents
    Tanajura, LF
    Abizaid, AA
    Fares, F
    Pinto, I
    Mattos, L
    Staico, R
    de Paula, J
    Abizaid, AS
    Centemero, M
    Chaves, AJ
    Peas, A
    Seixas, A
    Sousa, A
    Sousa, JEM
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 58A - 58A
  • [43] Fracture toughness and flexural strength of chemically vapor-deposited silicon carbide as determined using chevron-notched and surface crack in flexure specimens
    Cockeram, BV
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2004, 87 (06) : 1093 - 1101
  • [44] Relation between fracture surface area of a flexural strength specimen and fracture toughness for WC-10mass%Co cemented carbide and Si3N4
    The Univ of Tokyo, Tokyo, Japan
    Mater Sci Eng A Struct Mater Prop Microstruct Process, 1-2 (169-174):
  • [45] Mathematical modeling of fracture healing in mice: comparison between experimental data and numerical simulation results
    Liesbet Geris
    Alf Gerisch
    Christa Maes
    Geert Carmeliet
    Rüdiger Weiner
    Jos Vander Sloten
    Hans Van Oosterwyck
    Medical and Biological Engineering and Computing, 2006, 44 : 280 - 289
  • [46] Mathematical modeling of fracture healing in mice: comparison between experimental data and numerical simulation results
    Geris, Liesbet
    Gerisch, Alf
    Maes, Christa
    Carmeliet, Geert
    Weiner, Ruediger
    Sloten, Jos Vander
    Van Oosterwyck, Hans
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (04) : 280 - 289
  • [47] Comparison of cloudiness derived from MSG satellite data with standard surface observations - preliminary results for Poland
    Lapeta, Bozena
    Dyras, Izabela
    Serafin-Rek, Danuta
    Ustrnul, Zbigniew
    REMOTE SENSING OF CLOUDS AND THE ATMOSPHERE XI, 2006, 6362
  • [48] Surface Relief Versus Standard VCSELs: A Comparison Between Experimental and Hot-Cavity Model Results
    Debernardi, Pierluigi
    Kroner, Andrea
    Rinaldi, Fernando
    Michalzik, Rainer
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2009, 15 (03) : 828 - 837
  • [49] Relation between fracture surface area of a flexural strength specimen and fracture toughness for WC-10mass%Co cemented carbide and Si3N4 ceramics
    Yanaba, Y
    Hayashi, K
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1996, 209 (1-2): : 169 - 174
  • [50] Comparison of R-curves from single-edge V-notched-beam (SEVNB) and surface-crack-in-flexure (SCF) fracture-toughness test methods on multilayered alumina-zirconia composites
    Moon, R
    Bowman, K
    Trumble, K
    Rödel, J
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 2000, 83 (02) : 445 - 447