Primary histologic diagnosis using automated whole slide imaging: a validation study

被引:134
|
作者
Gilbertson, John [1 ,5 ]
Ho, Jonhan [1 ]
Anthony, Leslie [2 ]
Jukic, Drazen [3 ,4 ]
Yagi, Yukako [1 ]
Parwani, Anil [3 ]
机构
[1] Univ Pittsburgh Med Ctr, Ctr Pathol Informat, Pittsburgh, PA 15232 USA
[2] Univ Pittsburgh, Ctr Biomed Informat, Pittsburgh, PA 15213 USA
[3] Univ Pittsburgh Sch Med, Dept Pathol, Pittsburgh, PA 15232 USA
[4] Univ Pittsburgh Sch Med, Dept Dermatol, Pittsburgh, PA 15232 USA
[5] Univ Pittsburgh Med Ctr, Benedum Ctr Oncol Informat, Pittsburgh, PA 15232 USA
来源
BMC CLINICAL PATHOLOGY | 2006年 / 6卷
关键词
D O I
10.1186/1472-6890-6-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Only prototypes 5 years ago, high-speed, automated whole slide imaging (WSI) systems (also called digital slide systems, virtual microscopes or wide field imagers) are becoming increasingly capable and robust. Modern devices can capture a slide in 5 minutes at spatial sampling periods of less than 0.5 micron/pixel. The capacity to rapidly digitize large numbers of slides should eventually have a profound, positive impact on pathology. It is important, however, that pathologists validate these systems during development, not only to identify their limitations but to guide their evolution. Methods: Three pathologists fully signed out 25 cases representing 31 parts. The laboratory information system was used to simulate real-world sign-out conditions including entering a full diagnostic field and comment (when appropriate) and ordering special stains and recuts. For each case, discrepancies between diagnoses were documented by committee and a "consensus" report was formed and then compared with the microscope-based, sign-out report from the clinical archive. Results: In 17 of 25 cases there were no discrepancies between the individual study pathologist reports. In 8 of the remaining cases, there were 12 discrepancies, including 3 in which image quality could be at least partially implicated. When the WSI consensus diagnoses were compared with the original sign-out diagnoses, no significant discrepancies were found. Full text of the pathologist reports, the WSI consensus diagnoses, and the original sign-out diagnoses are available as an attachment to this publication. Conclusion: The results indicated that the image information contained in current whole slide images is sufficient for pathologists to make reliable diagnostic decisions and compose complex diagnostic reports. This is a very positive result; however, this does not mean that WSI is as good as a microscope. Virtually every slide had focal areas in which image quality (focus and dynamic range) was less than perfect. In some cases, there was evidence of over-compression and regions made "soft" by less than perfect focus. We expect systems will continue to get better, image quality and speed will continue to improve, but that further validation studies will be needed to guide development of this promising technology.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Whole slide imaging system using deep learning-based automated focusing
    Dastidar, Tathagato Rai
    Ethirajan, Renu
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (01): : 480 - 491
  • [32] Whole-slide Imaging: Routine Pathologic Diagnosis
    Cornish, Toby C.
    Swapp, Ryan E.
    Kaplan, Keith J.
    ADVANCES IN ANATOMIC PATHOLOGY, 2012, 19 (03) : 152 - 159
  • [33] EXTERNAL VALIDATION OF A DEEP LEARNING MODEL FOR WHOLE SLIDE IMAGE ANALYSIS IN THE HISTOLOGIC DIAGNOSIS OF DYSPLASTIC BARRETT'S ESOPHAGUS
    Codipilly, Don C.
    Faghani, Shahriar
    Sachdeva, Karan
    Gibbons, Erin
    Lansing, Ramona
    Passe, Melissa
    Leggett, Cadman L.
    Katzka, David A.
    Moassefi, Mana
    Rouzrokh, Pouria
    Khosravi, Bardia
    Hagen, Catherine E.
    Lewis, Jason T.
    Patil, Pallavi A.
    Konda, Vani
    Peter, Shajan
    Al Diffalha, Sameer
    Brinkerhoff, Brian
    Wong, Mary
    Otaki, Fouad
    Shaheen, Nicholas J.
    Erickson, Bradley
    Iyer, Prasad G.
    GASTROENTEROLOGY, 2023, 164 (06) : S41 - S42
  • [34] An Automated Blur Detection Method for Histological Whole Slide Imaging
    Lopez, Xavier Moles
    D'Andrea, Etienne
    Barbot, Paul
    Bridoux, Anne-Sophie
    Rorive, Sandrine
    Salmon, Isabelle
    Debeir, Olivier
    Decaestecker, Christine
    PLOS ONE, 2013, 8 (12):
  • [35] Comparison of whole-slide Imaging to robotic microscopy for primary frozen section diagnosis by telepathology
    Evans, A. J.
    Chettyv, R.
    Clarke, B. A.
    Croul, S.
    Kiehl, R.
    Perez-Ordonez, B.
    Asa, S. L.
    LABORATORY INVESTIGATION, 2008, 88 : 364A - 364A
  • [36] Evaluation of Applying High Throughput Whole Slide Imaging System for Primary Diagnosis of Daily Cases
    Lin, Yen-Yu
    Liang, Wen Yih
    MODERN PATHOLOGY, 2018, 31 : 592 - 592
  • [37] Comparison of whole-slide imaging to robotic microscopy for primary frozen section diagnosis by telepathology
    Evans, A. J.
    Chetty, R.
    Clarke, B. A.
    Croul, S.
    Kiehl, R.
    Perez-Ordonez, B.
    Asa, S. L.
    MODERN PATHOLOGY, 2008, 21 : 364A - 364A
  • [38] Evaluation of Applying High Throughput Whole Slide Imaging System for Primary Diagnosis of Daily Cases
    Lin, Yen-Yu
    Liang, Wen Yih
    LABORATORY INVESTIGATION, 2018, 98 : 592 - 592
  • [39] Whole slide imaging and colorectal carcinoma: A validation study for tumor budding and stromal differentiation
    Hacking, Sean
    Nasim, Rafae
    Lee, Lili
    Vitkovski, Taisia
    Thomas, Rebecca
    Shaffer, Emily
    Nasim, Mansoor
    PATHOLOGY RESEARCH AND PRACTICE, 2020, 216 (11)
  • [40] Automated analysis and diagnosis of skin melanoma on whole slide histopathological images
    Lu, Cheng
    Mandal, Mrinal