IS THE PENILE BRACHIAL INDEX A REPRODUCIBLE AND USEFUL MEASUREMENT

被引:8
|
作者
AITCHISON, M
AITCHISON, J
CARTER, R
机构
[1] Department of Urology, Royal Infirmary, Glasgow
来源
BRITISH JOURNAL OF UROLOGY | 1990年 / 66卷 / 02期
关键词
D O I
10.1111/j.1464-410X.1990.tb14904.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Summary –The intra‐ and inter‐observer variation in the measurement of the penile brachial index (PBI) was prospectively assessed in 30 patients. An appreciable error was discovered that cast doubt on the reliability of the measurements. Up to 20% of patients deemed normal by one observer would be deemed abnormal by a second. The PBI appears to be an inaccurate and poorly reproducible test of penile blood flow which can lead to a false diagnosis and subsequent management of impotent patients. There would appear no justification for the continued use of the penile brachial index in the assessment of erectile dysfunction. © 1990 British Journal of Urology
引用
收藏
页码:202 / 204
页数:3
相关论文
共 50 条
  • [32] Individual variations in ankle brachial index measurement among Turkish adults
    Demir, Orhan
    Tasci, Ilker
    Acikel, Cengizhan
    Saglam, Kenan
    Gezer, Mustafa
    Acar, Ramazan
    Yildiz, Birol
    Bulucu, Fatih
    Kabul, Hasan Kutsi
    Dogan, Mustafa Inanc
    Koc, Bayram
    VASCULAR, 2016, 24 (01) : 53 - 58
  • [33] Ankle-brachial index measurement: Skill Cannot be taken for granted
    Caspary, Ludwig
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2016, 45 (01) : 5 - 6
  • [34] Validation of automated oscillometric versus manual measurement of the ankle–brachial index
    Tom Richart
    Tatiana Kuznetsova
    Barbara Wizner
    Harry A Struijker-Boudier
    Jan A Staessen
    Hypertension Research, 2009, 32 : 884 - 888
  • [35] A test can be reproducible but still not useful
    Myers, ER
    FERTILITY AND STERILITY, 2004, 82 (05) : 1299 - 1299
  • [36] Measurement of Pulse Wave Velocity and Augmentation Index is Reproducible in Young, Healthy Men
    Casey, Darren P.
    Pierce, Gary L.
    Nichols, Wilmer W.
    Braith, Randy W.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (05): : S185 - S186
  • [37] Variation of method for measurement of brachial artery pressure significantly affects ankle-brachial pressure index values
    Jeelani, NUO
    Braithwaite, BD
    Tomlin, C
    MacSweeney, ST
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2000, 20 (01) : 25 - 28
  • [38] Ankle Brachial Index Screening for Occult Vascular Disease Is Not Useful in HIV-Positive Patients
    Johns, Kevin
    Saeedi, Ramesh
    Mancini, G. B. John
    Bondy, Greg
    AIDS RESEARCH AND HUMAN RETROVIRUSES, 2010, 26 (09) : 955 - 959
  • [39] Regarding the article: Is the use of the ankle-brachial index useful in patients with diabetes in primary care?
    Izquierdo, Michael Diaz
    Martinez, Jorge Luis Carrera
    Azahares, Isabel Hernandez
    de Armas, Kevin Macias
    ATENCION PRIMARIA, 2024, 56 (06):
  • [40] Are portable ankle brachial pressure index measurement devices suitable for hypertension screening?
    Janus, Justyna
    Nicholls, Jennifer K.
    Pallett, Edward
    Bown, Matthew
    Chung, Emma M. L.
    PLOS ONE, 2023, 18 (03):