FIRE-SAFE DESIGN OF MODERN STEEL BUILDINGS IN JAPAN

被引:4
|
作者
SAKUMOTO, YU [1 ]
SAITO, H [1 ]
机构
[1] CHIBA UNIV,CHIBA,JAPAN
关键词
D O I
10.1016/0143-974X(94)00019-E
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents fire-safe design of buildings using fire-resistant (FR) steel. Because of the elements contained, FR steel retains strength at high temperatures compared with conventional structural steels for buildings. Through the use of FR steel and fire-safe design calculating fire intensity, steel temperature and deformation of a frame at high temperature, FR steel can reduce thickness of fire protection materials compared with conventional structural steels and also can be used in steel buildings without any protection in cases where the steel temperature would not exceed 600-degrees-C. In this paper, the fire-safe design of Yokohama Sogo warehouse and Tobihata Building are presented together with the mechanical properties of FR steel and the design method of buildings using FR steel. Yokohama Sogo warehouse employs FR steel for its interior columns and beams by reducing the thickness of sprayed ceramic-cement protection according to required fire resistance in hours. In the Tobihata building, unprotected FR steel was used for its external frames since it was confirmed that the temperature of the frame heated by projecting flame would not exceed 600-degrees-C.
引用
收藏
页码:101 / 123
页数:23
相关论文
共 50 条
  • [41] FIRE-SAFE ROOF CONSTRUCTION .2.
    SOTIS, LP
    PLANT ENGINEERING, 1983, 37 (21) : 72 - 74
  • [42] GETTING SET FOR FIRE-SAFE TV CABINETS
    WOOD, AS
    MODERN PLASTICS, 1974, 51 (09): : 74 - 77
  • [43] POLYURETHANES NOW IN FIRE-SAFE FOAM FORM
    不详
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1961, 53 (08): : A32 - &
  • [44] FUSIBLE LINK ACTIVATES FIRE-SAFE VALVE SEAL
    BAK, DJ
    DESIGN NEWS, 1979, 35 (18) : 70 - 70
  • [45] Fire engineering design of steel and composite buildings
    Lawson, RM
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (12) : 1233 - 1247
  • [46] PROCESS VALVES AND ACTUATORS - MEETING FIRE-SAFE REQUIREMENTS
    BLICKLEY, GJ
    CONTROL ENGINEERING, 1985, 32 (09) : 118 - 120
  • [47] Plasticized polymer matrix composites for fire-safe construction
    Ushkov, Valentin
    Kopytin, Andrey
    Smirnov, Vladimir
    Alimov, Lev
    15TH INTERNATIONAL SCIENTIFIC CONFERENCE UNDERGROUND URBANISATION AS A PREREQUISITE FOR SUSTAINABLE DEVELOPMENT, 2016, 165 : 1823 - 1828
  • [48] HOW TO EFFECTIVELY SELECT FIRE-SAFE VALVES AND ACTUATORS
    SYMALLA, M
    HYDROCARBON PROCESSING, 1984, 63 (07): : 83 - 84
  • [49] FIRE-SAFE VALVES - MARKETING MYTH OR TECHNICAL TRUTH
    ARANT, JB
    INSTRUMENTATION TECHNOLOGY, 1981, 28 (12): : 9 - &
  • [50] Fire-safe polymer electrolyte strategies for lithium batteries
    Wu, Minghong
    Han, Shiheng
    Liu, Shumei
    Zhao, Jianqing
    Xie, Weiqi
    ENERGY STORAGE MATERIALS, 2024, 66