AMMONIUM DETECTION USING AN ION-SELECTIVE ELECTRODE ARRAY IN FLOW-INJECTION ANALYSIS

被引:26
|
作者
DEVITERI, FJS [1 ]
DIAMOND, D [1 ]
机构
[1] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
关键词
AMMONIUM; ION-SELECTIVE ELECTRODE; FLOW-INJECTION ANALYSIS; ARRAY;
D O I
10.1002/elan.1140060104
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ammonium detection system using ion-selective electrodes (ISEs) in flow-injection analysis (FIA) is described. Because of the low selectivity of the nonactin ammonium selective electrode toward some common ions, notably potassium, different selectivity enhancement techniques have been examined. An array of ISEs selective for ammonium, sodium, potassium, and calcium was used as the FIA detector, and the array response was modeled via the Nikolskii-Eisenmann equation and the Projection Pursuit regression model. The interfacing of the system to a PC-386SX computer using an Analog Devices RTI-815 I/O card is also described. The results show that the use of an array of ISEs under FIA regimes for the detection of ammonium in the activity range 10 to 0.01 mM,gives much improved results for the determination of ammonium in aqueous samples than the use of a single ammonium electrode. The 'performance of the array under steady-state and FIA conditions is compared.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 50 条
  • [21] Flow-injection potentiometric determination of free cadmium ions with a cadmium ion-selective electrode
    Trojanowicz, M
    Alexander, PW
    Brynn Hibbert, D
    ANALYTICA CHIMICA ACTA, 1998, 370 (2-3) : 267 - 278
  • [22] PHOTO-CURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES .2. A CALCIUM ELECTRODE FOR FLOW-INJECTION ANALYSIS
    CARDWELL, TJ
    CATTRALL, RW
    ILES, PJ
    HAMILTON, IC
    ANALYTICA CHIMICA ACTA, 1985, 177 : 239 - 242
  • [23] DETERMINATION OF AMMONIUM ION IN URINE USING AN AMMONIUM ION-SELECTIVE ELECTRODE
    MERKOCI, A
    COCOLI, V
    BARAJ, B
    BUZO, S
    ACTA CHIMICA HUNGARICA-MODELS IN CHEMISTRY, 1993, 130 (01): : 19 - 24
  • [24] PHOTO-CURED POLYMERS IN ION-SELECTIVE ELECTRODE MEMBRANES .3. A POTASSIUM ELECTRODE FOR FLOW-INJECTION ANALYSIS
    CARDWELL, TJ
    CATTRALL, RW
    ILES, PJ
    HAMILTON, IC
    ANALYTICA CHIMICA ACTA, 1988, 204 (1-2) : 329 - 332
  • [25] USE OF ION-SELECTIVE ELECTRODES AS ANION DETECTORS IN FLOW-INJECTION ANALYSIS AND ION CHROMATOGRAPHY
    KOLYCHEVA, NV
    MULLER, G
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1991, 46 (11): : 1626 - 1633
  • [27] Rejuvenation of a fluoride ion-selective electrode for use in flow injection analysis
    Iles, Peter
    Giddings, Luther
    Valcarce, Ron
    Alvarez, Mary
    Warren, Joseph
    Bastian, Neil
    Nagle, Afton Allen
    Reilly, Joan
    Jone, Zachary
    Moore, Sarah
    Shill, Otto
    Kamborian, Charles
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [28] Magnesium ion-selective electrode: optimization and flow injection analysis application
    Chaniotakis, NA
    Tsagatakis, JK
    Moschou, EA
    West, SJ
    Wen, XW
    ANALYTICA CHIMICA ACTA, 1997, 356 (01) : 105 - 111
  • [29] FLOW-INJECTION DETERMINATION OF THE TOTAL WATER HARDNESS BY USING A COPPER(II) ION-SELECTIVE ELECTRODE AND A COPPER(II) ION BUFFER
    IMATO, T
    ISHII, K
    ISHIBASHI, N
    ANALYTICAL SCIENCES, 1992, 8 (05) : 631 - 635
  • [30] Flow injection analysis for residual chlorine using Pb(II) ion-selective electrode detector
    Sakai, A
    Hemmi, A
    Hachiya, H
    Kobayashi, F
    Ito, S
    Asano, Y
    Imato, T
    Fushinuki, Y
    Taniguchi, I
    TALANTA, 1998, 45 (03) : 575 - 581