Radiation Dose Reduction for Barium Enema: an Achievable Improvement in Patient Care

被引:0
|
作者
Lai, B. M. H. [1 ]
Fung, V. K. P. [1 ]
Shum, J. S. F. [1 ]
Sy, A. N. L. [1 ]
Cheng, S. C. S. [1 ]
Khoo, J. L. S. [1 ]
机构
[1] Pamela Youde Nethersole Eastern Hosp, Dept Radiol, 3 Lok Man Rd, Chaiwan, Hong Kong, Peoples R China
来源
HONG KONG JOURNAL OF RADIOLOGY | 2011年 / 14卷 / 04期
关键词
Barium; Enema; Radiation dose;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the effectiveness and practicality of dose-reduction measures for double-contrast barium enema based on well-established UK National Reference Levels. Methods: Between May 2009 and February 2011, 369 patients were prospectively studied with respect to radiation doses received while undergoing double-contrast barium enema examinations before and after implementation of radiation dose-reduction measures. Statistical analysis was performed on fluoroscopic screening times, dose-area-product, and the number of undercouch and overcouch films used during the examination. Results: A significant reduction in fluoroscopic screening time (43%) was achieved after implementation of dose-reduction measures (p < 0.01). Similarly, a 40% reduction in dose-area-product was achieved at the end of the study (p < 0.01). Before the implementation of the dose-reduction measures, the mean dose-area-product and fluoroscopic screening time at our centre were at 73% and 58% above the UK National Reference Levels, respectively. At the end of the study, they were noted to be up to 13% lower than the UK standards. Conclusion: A 40% reduction in radiation dose on patients undergoing double-contrast barium enema was achieved after implementation of dose-reduction measures in our hospital. The double-contrast barium enema radiation dose was also reduced from 73% above the UK National Reference Level to a level below this reference standard.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 50 条
  • [1] Reduction of radiation dose to patients undergoing barium enema by dose audit
    Yu, SK
    Cheung, YK
    Chan, TL
    Kung, CM
    Yuen, MK
    BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (878): : 162 - 165
  • [2] REDUCTION OF INTUSSUSCEPTION BY BARIUM ENEMA
    RAVITCH, MM
    SURGERY GYNECOLOGY & OBSTETRICS, 1954, 99 (04): : 431 - 435
  • [3] REDUCTION OF INTUSSUSCEPTION BY BARIUM ENEMA
    RAVITCH, MM
    MORGAN, RH
    ANNALS OF SURGERY, 1952, 135 (05) : 596 - 605
  • [4] REDUCTION OF INTUSSUCEPTION BY BARIUM ENEMA
    BARZIV, J
    BARKY, Y
    HIRSCH, M
    SIPLOVICH, L
    MARES, A
    HAREFUAH, 1979, 96 (03) : 150 - 151
  • [5] Factors influencing patient radiation doses from barium enema examinations
    Vehmas, T
    Lampinen, JS
    Mertjärvi, A
    Rannikko, S
    ACTA RADIOLOGICA, 2000, 41 (02) : 167 - 171
  • [6] Patient dose variation investigated in four Irish hospitals for barium meal and barium enema examinations
    Carroll, E
    Brennan, PC
    RADIATION PROTECTION DOSIMETRY, 2001, 97 (03) : 275 - 278
  • [7] Dose reduction in double contrast barium enema by use of low fluoroscopic current
    Smiddy, PF
    Quinn, AD
    Freyne, PJ
    Marsh, D
    Murphy, JM
    BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (825): : 852 - 854
  • [8] Radiation dose and diagnosticity of barium enema examinations by radiographers and radiologists: a comparative study
    Crawley, MT
    Shine, B
    Booth, A
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (844): : 399 - 405
  • [9] BARIUM ENEMA REDUCTION OF GALLSTONE ILEUS
    WHITCOMB, JG
    BROMME, DA
    LOVELACE, WR
    AMERICAN JOURNAL OF SURGERY, 1963, 106 (04): : 592 - 596
  • [10] A rare case of intussusception in a patient with typhlitis managed successfully by barium enema reduction
    Chan, Simon C.
    Shah, Ashok
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 : S319 - S320