CONSIDERATION OF PULSE PRESSURE ANALYZING THE 24-HOUR BLOOD-PRESSURE MONITORING

被引:0
|
作者
ECKERMANN, R
机构
关键词
24-HOUR BLOOD PRESSURE PROFILE; PULSE PRESSURE; PULSATILE HEART ENERGY; BACK FLOW OF BLOOD;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Blood pressure readings at night do not show a decrease of pulse pressure as it should be expected following the drop of diastolic pressure. The functional connection between these 2 parameters is caused by the exponential shape of aortic elasticity. As shown by Fourier analysis the amount of pulsatile power ejected from the heart is big enough to be used as an essential part of the energy needed for the back flow of blood. Lack of this power transformation could then only be completed by higher blood pressure.
引用
收藏
页码:96 / 97
页数:2
相关论文
共 50 条
  • [21] 24-HOUR AMBULATORY BLOOD-PRESSURE MONITORING - A REVIEW OF VALIDATION DATA
    OBRIEN, E
    OMALLEY, K
    JOURNAL OF HYPERTENSION, 1990, 8 : S11 - S16
  • [22] OLECRANON BURSITIS ASSOCIATED WITH 24-HOUR AMBULATORY BLOOD-PRESSURE MONITORING
    MANSOOR, GA
    WHITE, WB
    AMERICAN JOURNAL OF HYPERTENSION, 1994, 7 (09) : 855 - 856
  • [23] 24-HOUR CONTINUOUS BLOOD-PRESSURE MONITORING IN HYPERTENSIVE PATIENTS ON HEMODIALYSIS
    LANG, G
    SABATINI, S
    VONRIOTTE, A
    KURTZMAN, NA
    BATLLE, DC
    KIDNEY INTERNATIONAL, 1983, 23 (01) : 153 - 153
  • [24] EFFICACY OF 24-HOUR AMBULATORY BLOOD-PRESSURE MONITORING (ABPM) IN CHILDREN
    PORTMAN, RJ
    YETMAN, RJ
    WEST, MS
    PEDIATRIC RESEARCH, 1989, 25 (04) : A104 - A104
  • [25] NONINVASIVE 24-HOUR AMBULATORY ARTERIAL BLOOD-PRESSURE MONITORING IN CIRRHOSIS
    MOLLER, S
    WIINBERG, N
    HENRIKSEN, JH
    HEPATOLOGY, 1995, 22 (01) : 88 - 95
  • [27] LABETALOL AND 24-HOUR MONITORING OF ARTERIAL BLOOD-PRESSURE IN HYPERTENSIVE PATIENTS
    FERRARI, A
    BUCCINO, N
    DIRIENZO, M
    PEDOTTI, A
    MANCIA, G
    ZANCHETTI, A
    JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1981, 3 : S42 - S52
  • [28] Automatic 24-hour blood pressure monitoring
    Gorbunov, VM
    KARDIOLOGIYA, 1997, 37 (06) : 96 - 104
  • [29] 24-hour ambulatory blood pressure monitoring
    Anlauf, M
    Baumgart, P
    Franz, IW
    Krönig, B
    Middeke, M
    Schrader, J
    Schulte, KL
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1998, 123 (47) : 1426 - 1430
  • [30] AMBULATORY 24-HOUR BLOOD-PRESSURE MONITORING - SIGNIFICANCE OF BLOOD-PRESSURE VARIABILITY FOR THE PROGRESSION OF CARDIAC-HYPERTROPHY
    MACHNIG, T
    ENGELS, G
    HENNEKE, KH
    GELLERT, J
    BACHMANN, K
    ZEITSCHRIFT FUR KARDIOLOGIE, 1993, 82 (03): : 187 - 191