Computed tomography enterography in assessment of Crohn's disease activity

被引:1
|
作者
Ibrahim, Enas Abdel Ghany [1 ]
El-Dieb, Leila Rawash [1 ]
Chalabi, Nivine [1 ]
Osman, Noha Mohamed [1 ]
机构
[1] Ain Shams Univ, Fac Med, Dept Radiodiag, Cairo, Egypt
关键词
Crohn's disease; CT enterography; Ileocolonoscopy;
D O I
10.1016/j.ajme.2014.04.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Monitoring the disease activity in Crohn's disease (CD) may be challenging with endoscopic manoeuvers due to difficulties in reaching the affected areas and being restricted to mucosal lesions, so the existence of a more tolerable and reliable technique will be highly warranted. Objectives: This study aims at detection of CD's activity by computed tomography enterography (CTE) in correlation with ileocolonoscopy evaluation as well as detection of extra-enteric manifestations and complications of the disease. Materials and methods: Twenty-four patients who were clinically and histopathologically proven as CD patients were retrospectively included in this study. Patients were divided into active and inactive groups according to ileocolonoscopic evaluation. All patients underwent CTE as clinically indicated within 1 week of ileocolonoscopy. Radiological parameters suggestive of Crohn's disease activity at CTE were interpreted at the terminal ileum and correlated to the corresponding ileocolonoscopy reports for signs of CD activity. Extra-enteric findings and complications of CD were also reported if present. Results: CTE was accurate in detecting CD activity in 15 out of 18 active cases (active group) and in detecting disease inactivity in 5 out of 6 inactive cases (inactive group) with sensitivity and specificity of 83.3%. Mural hyperenhancement was the most distinguished sign of CD activity in CTE. Conclusion: CTE is a non invasive and reliable technique that has a significant value in assessment of CD activity in correlation with endoscopy, hence, it is useful in follow up and preoperative guidance. (C) 2014 Alexandria University Faculty of Medicine. Production and hosting by Elsevier B.V. All rights reserved.
引用
收藏
页码:105 / 110
页数:6
相关论文
共 50 条
  • [21] Computed Tomography and Magnetic Resonance Enterography in Crohn's Disease: Assessment of Radiologic Criteria and Endpoints for Clinical Practice and Trials
    Deepak, Parakkal
    Fletcher, Joel G.
    Fidler, Jeff L.
    Bruining, David H.
    INFLAMMATORY BOWEL DISEASES, 2016, 22 (09) : 2280 - 2288
  • [22] MR Enterography in the Assessment of the Crohn's Disease
    Paspulati, R.
    Katz, J.
    Splawsky, J.
    Chelimsky, G.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [23] Improved comprehensive evaluation of Crohn?s disease activity by intestinal computed tomography enterography combined with endoscopy and biochemical indicators
    Liu, Yajun
    Tian, Feiyan
    Chen, Shuijiao
    Hu, Jiuye
    ARAB JOURNAL OF GASTROENTEROLOGY, 2023, 24 (01) : 16 - 23
  • [24] Crohn's Disease Activity Quantified by Iodine Density Obtained From Dual-Energy Computed Tomography Enterography
    Dane, Bari
    Duenas, Sean
    Han, Joseph
    O'Donnell, Thomas
    Ream, Justin
    Chang, Shannon
    Megibow, Alec
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2020, 44 (02) : 242 - 247
  • [25] COMPUTED TOMOGRAPHY ENTEROGRAPHY (CT) AND SMALL BOWEL ULTRASOUND (US) IN ASSESSING ILEAL CROHN'S DISEASE (CD) ACTIVITY
    Losco, A.
    Trattenero, C.
    Fraquelli, M.
    Forzenigo, L. V.
    Massironi, S.
    Pirola, L.
    Conte, D.
    Biondetti, P.
    Basilisco, G.
    DIGESTIVE AND LIVER DISEASE, 2008, 40 : S132 - S133
  • [26] Computed Tomography Enterography Versus Magnetic Resonance Enterography for Assessment of Disease Activity and Complications in Small Bowel Crohn's Disease: A Meta-Analysis of Head-to-Head Comparative Studies
    Qiu, Yun
    Mao, Ren
    Chen, Bai-li
    He, Yao
    Zeng, Zhirong
    Chen, Minhu
    GASTROENTEROLOGY, 2014, 146 (05) : S428 - S429
  • [27] Utility of Computed Tomographic Enteroclysis/Enterography for the Assessment of Mucosal Healing in Crohn's Disease
    Hashimoto, Shinichi
    Shimizu, Kensaku
    Shibata, Hiroaki
    Kanayama, Satoko
    Tanabe, Ryo
    Onoda, Hideko
    Matsunaga, Naohumi
    Sakaida, Isao
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2013, 2013
  • [28] Computed tomography enterography and biomarkers in detecting active and complicated small bowel Crohn's Disease
    Brincat, A.
    Micallef, K.
    Azzopardi, N.
    Ellul, P.
    JOURNAL OF CROHNS & COLITIS, 2015, 9 : S171 - S171
  • [29] Systematic review with meta-analysis: magnetic resonance enterography vs. computed tomography enterography for evaluating disease activity in small bowel Crohn's disease
    Qiu, Y.
    Mao, R.
    Chen, B. -L.
    Li, X. -H.
    He, Y.
    Zeng, Z. -R.
    Li, Z. -P.
    Chen, M. -H.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2014, 40 (02) : 134 - 146
  • [30] Magnetic Resonance Enterography in the Assessment of the Disease Activity in Crohn's Disease - A Retrospective Study
    Horjus, Carmen S.
    Bruijnen, Rutger
    De Jong, Dirk J.
    van Oijen, Martijn G.
    Groenen, Marcel J.
    Joosten, Frank B.
    Wahab, Peter J.
    GASTROENTEROLOGY, 2010, 138 (05) : S527 - S527