Metal artefact reduction in computed tomography images by a fourth-order total variation flow

被引:2
|
作者
Faggiano, Elena [1 ,2 ]
Lorenzi, Tommaso [3 ,4 ,5 ]
Quarteroni, Alfio [6 ]
机构
[1] Politecn Milan, Dept Math Modelling & Sci Comp MOX, I-20133 Milan, Italy
[2] Politecn Milan, Lab Biol Struct Mech LaBs, Dept Chem Mat & Chem Engn, I-20133 Milan, Italy
[3] Univ Paris 06, Lab Jacques Louis Lions, Sorbonne Univ, UMR 7598, F-75005 Paris, France
[4] CNRS, UMR 7598, Lab Jacques Louis Lions, F-75005 Paris, France
[5] EPC MAMBA, INRIA Paris Rocquencourt, BP105, F-78153 Le Chesnay, France
[6] Ecole Polytech Fed Lausanne, Modeling & Sci Comp CMCS, MATHICSE, Lausanne, Switzerland
基金
欧洲研究理事会;
关键词
metal artefact reduction; computed tomography; image inpainting; variational and PDE methods;
D O I
10.1080/21681163.2014.940629
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Permanent metallic implants, such as dental fillings and cardiac devices, generate streaks-like artefacts in computed tomography (CT) images. In this article, we propose a strategy to perform metal artefact reduction (MAR) that relies on the total variation-H-1 inpainting, a variational approach based on a fourth-order total variation (TV) flow. This approach has never been used to perform MAR, although it has been profitably employed in other branches of image processing. A systematic evaluation of the performance is carried out. Comparisons are made with the results obtained using classical linear interpolation and two other partial differential equation-based approaches relying, respectively, on the Fourier's heat equation and on a second order TV flow. Visual inspection of both synthetic and real CT images, as well as computation of similarity indexes, suggests that our strategy for MAR outperforms the others considered here, as it provides best image restoration, highest similarity indexes and for being the only one able to recover hidden structures, a task of primary importance in the medical field.
引用
收藏
页码:202 / 213
页数:12
相关论文
共 50 条
  • [21] Active reduction of fluctuations in fourth-order modulation instability
    Hammani, K.
    Finot, C.
    Habert, R.
    Mussot, A.
    Kudlinski, A.
    OPTICS LETTERS, 2012, 37 (20) : 4305 - 4307
  • [22] REDUCTION OF FOURTH-ORDER ASYMMETRIC-ROTOR HAMILTONIAN
    KNEIZYS, FX
    FREEDMAN, JN
    CLOUGH, SA
    JOURNAL OF CHEMICAL PHYSICS, 1966, 44 (07): : 2552 - &
  • [23] The impact of fourth-order exchange interactions on the thermal variation of the order parameter
    U. Köbler
    A. Hoser
    K. Fischer
    M. Beyss
    Applied Physics A, 2002, 74 : s604 - s606
  • [24] The impact of fourth-order exchange interactions on the thermal variation of the order parameter
    Köbler, U
    Hoser, A
    Fischer, K
    Beyss, M
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2002, 74 (Suppl 1): : S604 - S606
  • [25] A C0 interior penalty discontinuous Galerkin Method for fourth-order total variation flow. II: Existence and uniqueness
    Bhandari, Chandi
    Hoppe, Ronald H. W.
    Kumar, Rahul
    NUMERICAL METHODS FOR PARTIAL DIFFERENTIAL EQUATIONS, 2019, 35 (04) : 1477 - 1496
  • [26] A fourth-order eigenvalue problem arising in viscoelastic flow
    Olagunju, DO
    APPLIED MATHEMATICS LETTERS, 2005, 18 (07) : 805 - 810
  • [27] Numerical computations of split Bregman method for fourth order total variation flow
    Giga, Yoshikazu
    Ueda, Yuki
    JOURNAL OF COMPUTATIONAL PHYSICS, 2020, 405
  • [28] Visual grading evaluation of commercially available metal artefact reduction techniques in hip prosthesis computed tomography
    Andersson, Karin M.
    Norrman, Eva
    Geijer, Hakan
    Krauss, Wolfgang
    Cao, Yang
    Jendeberg, Johan
    Geijer, Mats
    Liden, Mats
    Thunberg, Per
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063):
  • [29] Metal Artifact Reduction on Chest Computed Tomography Examinations: Comparison of the Iterative Metallic Artefact Reduction Algorithm and the Monoenergetic Approach
    Pagniez, Julien
    Legrand, Louise
    Khung, Suonita
    Faivre, Jean-Baptiste
    Duhamel, Alain
    Krauss, Andreas
    Remy, Jacques
    Remy-Jardin, Martine
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (03) : 446 - 454
  • [30] Second order total generalized variation for speckle reduction in ultrasound images
    Mei, Jin-Jin
    Huang, Ting-Zhu
    Wang, Si
    Zhao, Xi-Le
    JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2018, 355 (01): : 574 - 595