Metal artefact reduction in computed tomography images by a fourth-order total variation flow

被引:2
|
作者
Faggiano, Elena [1 ,2 ]
Lorenzi, Tommaso [3 ,4 ,5 ]
Quarteroni, Alfio [6 ]
机构
[1] Politecn Milan, Dept Math Modelling & Sci Comp MOX, I-20133 Milan, Italy
[2] Politecn Milan, Lab Biol Struct Mech LaBs, Dept Chem Mat & Chem Engn, I-20133 Milan, Italy
[3] Univ Paris 06, Lab Jacques Louis Lions, Sorbonne Univ, UMR 7598, F-75005 Paris, France
[4] CNRS, UMR 7598, Lab Jacques Louis Lions, F-75005 Paris, France
[5] EPC MAMBA, INRIA Paris Rocquencourt, BP105, F-78153 Le Chesnay, France
[6] Ecole Polytech Fed Lausanne, Modeling & Sci Comp CMCS, MATHICSE, Lausanne, Switzerland
基金
欧洲研究理事会;
关键词
metal artefact reduction; computed tomography; image inpainting; variational and PDE methods;
D O I
10.1080/21681163.2014.940629
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Permanent metallic implants, such as dental fillings and cardiac devices, generate streaks-like artefacts in computed tomography (CT) images. In this article, we propose a strategy to perform metal artefact reduction (MAR) that relies on the total variation-H-1 inpainting, a variational approach based on a fourth-order total variation (TV) flow. This approach has never been used to perform MAR, although it has been profitably employed in other branches of image processing. A systematic evaluation of the performance is carried out. Comparisons are made with the results obtained using classical linear interpolation and two other partial differential equation-based approaches relying, respectively, on the Fourier's heat equation and on a second order TV flow. Visual inspection of both synthetic and real CT images, as well as computation of similarity indexes, suggests that our strategy for MAR outperforms the others considered here, as it provides best image restoration, highest similarity indexes and for being the only one able to recover hidden structures, a task of primary importance in the medical field.
引用
收藏
页码:202 / 213
页数:12
相关论文
共 50 条
  • [1] The fourth-order total variation flow in Rn
    Giga, Yoshikazu
    Kuroda, Hirotoshi
    Lasica, Michal
    MATHEMATICS IN ENGINEERING, 2023, 5 (06): : 1 - 45
  • [2] An experimental survey of metal artefact reduction in computed tomography
    Mouton, Andre
    Megherbi, Najla
    Van Slambrouck, Katrien
    Nuyts, Johan
    Breckon, Toby P.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (02) : 193 - 226
  • [3] Frequency split metal artefact reduction in pelvic computed tomography
    Lell, M. M.
    Meyer, E.
    Schmid, M.
    Raupach, R.
    May, M. S.
    Uder, M.
    Kachelriess, M.
    EUROPEAN RADIOLOGY, 2013, 23 (08) : 2137 - 2145
  • [4] Customized Total Variation Algorithm for Metal Artifact Reduction in Computed Tomography
    Deng, Ziheng
    Zhou, Yufu
    Zhang, Weikang
    Lin, Zefan
    Zhao, Jun
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 3479 - 3482
  • [5] A DISTANCE DRIVEN METHOD FOR METAL ARTEFACT REDUCTION IN COMPUTED TOMOGRAPHY
    Mouton, Andre
    Megherbi, Najla
    Van Slambrouck, Katrien
    Nuyts, Johan
    Breckon, Toby P.
    2013 20TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP 2013), 2013, : 2334 - 2338
  • [6] Frequency split metal artefact reduction in pelvic computed tomography
    M. M. Lell
    E. Meyer
    M. Schmid
    R. Raupach
    M. S. May
    M. Uder
    M. Kachelriess
    European Radiology, 2013, 23 : 2137 - 2145
  • [7] Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials
    Polyane Mazucatto Queiroz
    Matheus Lima Oliveira
    Francisco Carlos Groppo
    Francisco Haiter-Neto
    Deborah Queiroz Freitas
    Clinical Oral Investigations, 2018, 22 : 419 - 423
  • [8] Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials
    Queiroz, Polyane Mazucatto
    Oliveira, Matheus Lima
    Groppo, Francisco Carlos
    Haiter-Neto, Francisco
    Freitas, Deborah Queiroz
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (01) : 419 - 423
  • [9] A Combination of the Total Variation Filter and a Fourth-Order Filter for Image Registration
    Yang, Xiaomei
    Shen, Chaomin
    Li, Fang
    Shen, Chunli
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2015, 2015
  • [10] Synchronous Artefact Reduction in Industrial Computed Tomography
    Franz, Matthias
    Kasperl, Stefan
    Stamminger, Marc
    TM-TECHNISCHES MESSEN, 2010, 77 (11) : 616 - 623