ORIFICE VARIABILITY OF THE STENOTIC AORTIC-VALVE - EVALUATION BEFORE AND AFTER BALLOON AORTIC VALVULOPLASTY

被引:16
|
作者
PAULUS, WJ
SYS, SU
HEYNDRICKX, GR
ANDRIES, E
机构
关键词
D O I
10.1016/S0735-1097(10)80133-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The effects of balloon aortic valvuloplasty on orifice variability of the stenotic sclerocalcific aortic valve were evaluated by hemodynamic measurements of aortic valve function in 14 patients before balloon aortic valvuloplasty, during nitroprusside infusion before valvuloplasty, 48 h after valvuloplasty and during nitroprusside infusion 48 h after valvuloplasty. Aortic valve function was assessed by aortic valve area calculations with use of the Gorlin and Cannon formulas. Nitroprusside infusion before balloon aortic valvuloplasty caused no change in mean aortic valve gradient but a significant increase in mean aortic transvalvular flow from 186 +/- 46 to 202 +/- 61 ml/s (p < 0.05), in Gorlin aortic valve area from 0.49 +/- 0.17 to 0.53 +/- 0.21 cm2 (p < 0.05) and in Cannon aortic valve area from 0.45 +/- 0.18 to 0.49 +/- 0.22 cm2 (p < 0.05). Nitroprusside infusion 48 h after valvuloplasty induced no change in mean aortic valve gradient but a significant increase in mean aortic transvalvular flow from 214 +/- 61 to 254 +/- 78 ml/s (p < 0.005), in Gorlin aortic valve area from 0.71 +/- 0.25 to 0.83 +/- 0.32 cm2 (p < 0.01) and in Cannon aortic valve area from 0.78 +/- 0.33 to 0.88 +/- 0.40 cm2 (p < 0.05). Forty-eight hours after valvuloplasty, nitroprusside infusion induced a larger increase (40 +/- 40 ml/s) in mean transvalvular flow than before valvuloplasty (16 +/- 27 ml/s; p < 0.05) and a larger increase (0.12 +/- 0.14 cm2) in Gorlin aortic valve area than before valvuloplasty (0.05 +/- 0.07 cm2; p < 0.05). Balloon aortic valvuloplasty, which causes splitting of fused commissures and fracturing of calcific deposits within the valve leaflets, reduces the inertia of the leaflets during their opening motion. This explains the larger increment after balloon aortic valvuloplasty of effective valve orifice, when transvalvular flow is increased during nitroprusside infusion.
引用
收藏
页码:1263 / 1269
页数:7
相关论文
共 50 条
  • [21] PERCUTANEOUS TRANS-LUMINAL VALVULOPLASTY OF A STENOTIC AND CALCIFIC AORTIC-VALVE IN THE ELDERLY
    ZENKER, G
    LAMMER, J
    HUDABIUNIGG, K
    FORCHE, G
    HARNONCOURT, K
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 1987, 137 (10-11) : 252 - 255
  • [22] AORTIC-VALVE DISRUPTION AFTER PERCUTANEOUS AORTIC BALLOON VALVOPLASTY
    BRDLIK, O
    LAUB, GW
    FERNANDEZ, J
    MORSE, D
    SUTTER, FP
    MCGRAITH, LB
    ANNALS OF THORACIC SURGERY, 1990, 49 (05): : 822 - 823
  • [23] RARE ASSOCIATION OF TETRALOGY OF FALLOT AND AORTIC-VALVE STENOSIS - AUTOPSY FINDINGS AFTER FAILED BALLOON AORTIC VALVULOPLASTY
    INO, T
    YABUTA, K
    OKADA, R
    JAPANESE HEART JOURNAL, 1992, 33 (01): : 125 - 130
  • [24] Aortic valve repair and replacement after balloon aortic valvuloplasty in children
    Hawkins, JA
    Minich, LLA
    Shaddy, RE
    Tani, LY
    Orsmond, GS
    Sturtevant, JE
    McGough, EC
    ANNALS OF THORACIC SURGERY, 1996, 61 (05): : 1355 - 1358
  • [25] BALLOON DILATION OF STENOTIC AORTIC-VALVE IN CHILDREN - AN INTRAOPERATIVE STUDY - REPLY
    SOLYMAR, L
    SUDOW, G
    BERGGREN, H
    ERIKSSON, BO
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 107 (02): : 630 - 631
  • [26] CATHETER SELECTION FOR THE STENOTIC AORTIC-VALVE
    KERN, MJ
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 17 (03): : 190 - 191
  • [27] ORIFICE-VIEW ROENTGENOGRAPHY FOR EVALUATION OF AORTIC-VALVE
    STEIN, PD
    SABBAH, HN
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1975, 125 (04) : 847 - 853
  • [28] Aortic Valve Surgery After Neonatal Balloon Aortic Valvuloplasty in Congenital Aortic Stenosis
    Kido, Takashi
    Guariento, Alvise
    Doulamis, Ilias P.
    Porras, Diego
    Baird, Christopher W.
    del Nido, Pedro J.
    Nathan, Meena
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (06) : 573 - 581
  • [29] TRANSESOPHAGEAL AND DOPPLER-ECHOCARDIOGRAPHIC INVESTIGATIONS BEFORE AND AFTER PERCUTANEOUS BALLOON VALVULOPLASTY OF THE AORTIC ORIFICE
    GEIBEL, A
    KASPER, W
    MEINERTZ, T
    JUST, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1990, 79 (03): : 176 - 182
  • [30] HEMODYNAMIC-CHANGES FOLLOWING PERCUTANEOUS AORTIC-VALVE BALLOON VALVULOPLASTY
    DEAN, LS
    SAENZ, CB
    KIRKLIN, JW
    BAXLEY, WA
    CHERRE, JM
    BULLE, TM
    CLINICAL RESEARCH, 1988, 36 (01): : A3 - A3