CONTROL OF BUILDINGS USING ACTIVE - TUNED MASS DAMPERS

被引:85
|
作者
CHANG, CC [1 ]
YANG, HTY [1 ]
机构
[1] UNIV CALIF SANTA BARBARA,SANTA BARBARA,CA 93106
来源
JOURNAL OF ENGINEERING MECHANICS-ASCE | 1995年 / 121卷 / 03期
关键词
18;
D O I
10.1061/(ASCE)0733-9399(1995)121:3(355)
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A closed-loop complete-feedback control algorithm is proposed for the control of a building modeled as a single-degree-of-freedom (SDOF) system using an active tuned mass damper (ATMD). The control force is calculated from the acceleration, velocity, and displacement feedbacks of the SDOF system and the active mass damper. The passive-control-device properties, including the stiffness and damping constants of the tuned mass damper and the three gain coefficients of the actuator, are derived by minimizing the displacement variance of the SDOF system. Simulations are performed to evaluate the performance of the active-tuned-mass-damper design on the examples of a SDOF system and a 10-story three-bay building frame. The results show that the control efficiency of the ATMD based on velocity feedback depends on the passive-control-device properties assumed. Also, the ATMD with optimal passive properties using complete feedback results in further reduction in the structural displacement. The results also show that for the same level of reduction in structural displacements, the control force required is smaller using complete feedback.
引用
收藏
页码:355 / 366
页数:12
相关论文
共 50 条
  • [31] INTEGRATED MULTIPLE TUNED MASS DAMPERS FOR TALL BUILDINGS
    Moon, Kyoung Sun
    SUSTAINABLE SOLUTIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, 2014, : 271 - 276
  • [32] SEISMIC EFFECTIVENESS OF ACTIVE TUNED MASS DAMPERS FOR THE CONTROL OF FLEXIBLE STRUCTURES
    LOH, CH
    CHERN, WY
    PROBABILISTIC ENGINEERING MECHANICS, 1994, 9 (04) : 225 - 234
  • [33] Control of buildings using single and multiple tuned liquid column dampers
    Hong Kong Univ of Science and, Technology, Kowloon, Hong Kong
    Struct Eng Mech, 1 (77-93):
  • [34] Optimal structural control of tall buildings using tuned mass dampers via chaotic optimization algorithm
    Kaveh, A.
    Javadi, S. M.
    Moghanni, R. Mahdipour
    STRUCTURES, 2020, 28 : 2704 - 2713
  • [35] Seismic response reduction of irregular buildings using passive tuned mass dampers
    Lin, CC
    Ueng, JM
    Huang, TC
    ENGINEERING STRUCTURES, 2000, 22 (05) : 513 - 524
  • [36] SEMI-ACTIVE VERSUS PASSIVE OR ACTIVE TUNED MASS DAMPERS FOR STRUCTURAL CONTROL
    HROVAT, D
    BARAK, P
    RABINS, M
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 1983, 109 (03): : 691 - 705
  • [37] VIBRATION CONTROL IN A GERBER BEAM USING TUNED MASS DAMPERS
    Lara, Luis A., V
    Brito, Josp L. V.
    Avila, Suzana M.
    DYNA-COLOMBIA, 2010, 77 (164): : 119 - 129
  • [38] Characteristics of active multiple tuned mass dampers for asymmetric buildings under seismic action - II: Torsional vibration control
    Li, Chun-Xiang
    Zhang, Li-Qing
    Zhendong yu Chongji/Journal of Vibration and Shock, 2007, 26 (08): : 50 - 54
  • [39] Optimum placement and design of multiple tuned mass dampers for vibration control of asymmetric buildings
    Wang, Jer-Fu
    Lin, Ging-Long
    Lin, Chi-Chang
    Jian, Jie-Yong
    JOURNAL OF VIBRATION AND CONTROL, 2022, 28 (23-24) : 3875 - 3889
  • [40] Effect of Multiple Tuned Mass Dampers for Vibration Control in High-Rise Buildings
    Suresh, Lekshmi
    Mini, K. M.
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2019, 24 (04)