Risk factors for post-extubation stridor in children: the role of orotracheal cannula

被引:18
|
作者
Nascimento, Milena Siciliano [1 ]
Prado, Cristiane [1 ]
Troster, Eduardo Juan [1 ]
Valerio, Naiana [1 ]
Alith, Marcela Batan [2 ]
Lourenco de Almeida, Joao Fernando [1 ]
机构
[1] Hosp Israelita Albert Einstein, Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Hosp Univ, Sao Paulo, SP, Brazil
来源
EINSTEIN-SAO PAULO | 2015年 / 13卷 / 02期
关键词
Respiratory sounds; Risk factors; Intubation; intratracheal/instrumentation; Child;
D O I
10.1590/S1679-45082015AO3255
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To determine the risk factors associated with stridor, with special attention to the role of the cuffed orotracheal cannula. Methods: Prospective analysis of all the intubated patients submitted to mechanical ventilator support from January 2008 to April 2011. The relevant factors for stridor collected were age, weight, size and type of airway tube, diagnosis, and duration of mechanical ventilation. The effects of variables on stridor were evaluated using uni- and multivariate logistic regression models. Results: A total of 136 patients were included. Mean age was 1.4 year (3 days to 17 years). The mean duration of mechanical ventilation was 73.5 hours. Fifty-six patients (41.2%) presented with stridor after extubation. The total reintubation rate was 19.6% and 12.5 in patients with and without stridor, respectively. The duration of mechanical ventilation (>72 hours) was associated with a greater risk for stridor (odds ratio of 8.60; 95% confidence interval of 2.98-24.82; p<0.001). The presence of the cuffed orotracheal cannula was not associated with stridor (odds ratio of 98; 95% confidence interval of 0.46-2.06; p=0.953). Conclusion: The main risk factor for stridor after extubation in our population was duration of mechanical ventilation. The presence of the cuffed orotracheal cannula was not associated with increased risk for stridor, reinforcing the use of the cuffed orotracheal cannula in children with respiratory distress.
引用
收藏
页码:226 / 231
页数:6
相关论文
共 50 条
  • [31] Cuff Leak Test for the Diagnosis of Post-Extubation Stridor: A Multicenter Evaluation Study
    Schnell, David
    Planquette, Benjamin
    Berger, Asael
    Merceron, Sybille
    Mayaux, Julien
    Strasbach, Lucas
    Legriel, Stephane
    Valade, Sandrine
    Darmon, Michael
    Meziani, Ferhat
    JOURNAL OF INTENSIVE CARE MEDICINE, 2019, 34 (05) : 391 - 396
  • [32] Predictors of post-extubation stridor in patients on mechanical ventilation: a prospective observational study
    Aiko Tanaka
    Akinori Uchiyama
    Yu Horiguchi
    Ryota Higeno
    Ryota Sakaguchi
    Yukiko Koyama
    Hironori Ebishima
    Takeshi Yoshida
    Atsuhiro Matsumoto
    Kanaki Sakai
    Daisuke Hiramatsu
    Naoya Iguchi
    Noriyuki Ohta
    Yuji Fujino
    Scientific Reports, 11
  • [33] Measurement of leak volume as a diagnostic predictor of post-extubation stridor in pediatric patients
    Jetanachai, Pravit
    Pojthaveekiet, Jariya
    PAEDIATRICA INDONESIANA, 2024, 64 (05) : 384 - 388
  • [34] Predictors of post-extubation stridor in patients on mechanical ventilation: a prospective observational study
    Tanaka, Aiko
    Uchiyama, Akinori
    Horiguchi, Yu
    Higeno, Ryota
    Sakaguchi, Ryota
    Koyama, Yukiko
    Ebishima, Hironori
    Yoshida, Takeshi
    Matsumoto, Atsuhiro
    Sakai, Kanaki
    Hiramatsu, Daisuke
    Iguchi, Naoya
    Ohta, Noriyuki
    Fujino, Yuji
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [35] Laryngeal ultrasound versus cuff leak test in prediction of post-extubation stridor
    Mai A. Sahbal
    Kamel A. Mohamed
    Hanan H. Zaghla
    Mahmoud M. Kenawy
    The Egyptian Journal of Critical Care Medicine, 2017, 5 (3) : 83 - 86
  • [36] Should we Abandon the Cuff Leak Test to Predict Post-Extubation Stridor?
    Schnell, D.
    Darmon, M.
    Meziani, F.
    REANIMATION, 2015, 24 (01): : 63 - 70
  • [37] Post-extubation stridor in intensive care unit patientsRisk factors evaluation and importance of the cuff-leak test
    Samir Jaber
    Gérald Chanques
    Stefan Matecki
    Michèle Ramonatxo
    Christine Vergne
    Bruno Souche
    Pierre-François Perrigault
    Jean-Jacques Eledjam
    Intensive Care Medicine, 2003, 29 : 69 - 74
  • [38] Nebulized Corticosteroid For Preventing Post-Extubation Stridor In Children: A Randomized, Double Blind Controlled Trial (preliminary Study)
    Prasertsan, P.
    Anantasit, N.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [39] Effectiveness of corticosteroids for post-extubation stridor and extubation failure in pediatric patients: a systematic review and meta-analysis
    Kimura, Satoshi
    Ahn, JiYoon B.
    Takahashi, Mai
    Kwon, Sohee
    Papatheodorou, Stefania
    ANNALS OF INTENSIVE CARE, 2020, 10 (01)
  • [40] PAROXYSMAL SUPRAVENTRICULAR TACHYCARDIA IN A NEONATE - COMPLICATION OF RACEMIC EPINEPHRINE INHALATION FOR POST-EXTUBATION STRIDOR
    CALDWELL, CC
    LEVKOFF, AH
    PUROHIT, DM
    CLINICAL PEDIATRICS, 1977, 16 (06) : 579 - 580