DETECTION AND MEASUREMENT OF SIMULATED EARLY RHEUMATOID LESIONS OF THE HAND USING DIGITAL SUBTRACTION RADIOGRAPHY

被引:4
|
作者
BOLANDER, ME
GARDINER, J
COYLE, J
JOYCE, M
HIMMEL, HH
THORNTON, BC
RUTTIMANN, UE
机构
[1] WARREN GRANT MAGNUSON CLIN CTR,BETHESDA,MD
[2] NIDR,DIAGNOST SYST BRANCH,BETHESDA,MD 20205
[3] UNIV VIRGINIA,MED CTR,SCH MED,CHARLOTTESVILLE,VA 22901
关键词
Arthritis hand; Digital radiography; Erosive lesions; Image analysis; Quantitation;
D O I
10.1097/00004424-199006000-00016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The ability of digital subtraction radiography, a new technique to detect and quantify small bone lesions, is demonstrated. Discrete lesions in the metacarpals of cadaver hands simulated erosive bone loss. Radiographs made before and after removal of bone were digitized and subtracted. Density changes on subtraction images were determined, and bone loss was estimated by an automatic procedure that compared changes in radiographic density with a calibration wedge included in the radiographs. Comparison of estimated bone loss with the weight of bone removed showed reproducible detection and measurement of bone lesions as small as 4.6 mg, a size undetectable using current radiographic methods. Subtraction radiographs of bone chips overlaid on the hand of a volunteer indicated detection limits were similar in vivo. This technique enhanced the radiographic visibility of erosive lesions and thus has the potential to improve the detection of subtle bone changes in clinical settings. © Lippincott-Raven Publishers.
引用
收藏
页码:708 / 713
页数:6
相关论文
共 50 条
  • [21] Accuracy of Digital Subtraction Radiography in the Detection of Vertical Root Fractures
    Queiroz, Polyane Mazucatto
    Ribeiro Nascimento, Helena Aguiar
    Jacome da Paz, Thais Diniz
    Anacleto, Felipe Nogueira
    Freitas, Deborah Queiroz
    JOURNAL OF ENDODONTICS, 2016, 42 (06) : 896 - 899
  • [22] Accuracy of digital subtraction radiography for detection of bone changes.
    Christgau, M
    Hiller, KA
    Schmalz, G
    Kolbeck, C
    Wenzel, A
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 139 - 139
  • [23] Evaluation of chronic periapical lesions by digital subtraction radiography by using adobe photoshop CS:: A technical report
    Carvalho, Fabiola B.
    Goncalves, Marcelo
    Tanomaru-Filho, Mdrio
    JOURNAL OF ENDODONTICS, 2007, 33 (04) : 493 - 497
  • [24] Simplified endodontic treatments of periapical lesions: clinical assessment with Digital Subtraction Radiography
    Angerame, Daniele
    Sossi, Davide
    De Biasi, Matteo
    Tommasin, Elia
    Castaldo, Attilio
    Marigo, Luca
    Castagnola, Raffaella
    Somma, Francesco
    GIORNALE ITALIANO DI ENDODONZIA, 2013, 27 (01): : 50 - 53
  • [25] Reproducibility of and file format effect on digital subtraction radiography of simulated external root resorptions
    Gegler, A
    Mahl, C
    Fontanella, V
    DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (01) : 10 - 13
  • [26] Digital chest radiography: Effect of temporal subtraction images on detection accuracy
    Difazio, MC
    MacMahon, H
    Xu, XW
    Tsai, P
    Shiraishi, J
    Armato, SG
    Doi, K
    RADIOLOGY, 1997, 202 (02) : 447 - 452
  • [27] ASSESSMENT OF EXTERNAL ROOT RESORPTION USING DIGITAL SUBTRACTION RADIOGRAPHY
    KRAVITZ, LH
    TYNDALL, DA
    BAGNELL, CP
    DOVE, SB
    JOURNAL OF ENDODONTICS, 1992, 18 (06) : 275 - 284
  • [28] INVESTIGATION OF BASIC IMAGING PROPERTIES IN DIGITAL RADIOGRAPHY .8. DETECTION OF SIMULATED LOW-CONTRAST OBJECTS IN DIGITAL SUBTRACTION ANGIOGRAPHIC IMAGES
    OHARA, K
    CHAN, HP
    DOI, K
    GIGER, ML
    FUJITA, H
    MEDICAL PHYSICS, 1986, 13 (03) : 304 - 311
  • [29] Computed radiography and direct radiography -: Influence of acquisition dose on the detection of simulated lung lesions
    Uffmann, M
    Prokop, M
    Eisenhuber, E
    Fuchsjäger, M
    Weber, M
    Schaefer-Prokop, C
    INVESTIGATIVE RADIOLOGY, 2005, 40 (05) : 249 - 256
  • [30] Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions
    SchaeferProkop, CM
    Prokop, M
    Schmidt, A
    Neitzel, U
    Galanski, M
    RADIOLOGY, 1996, 201 (01) : 45 - 50