摘要
The analysis of EIT phantom outline voltage measuring accuracy is carried out in this article. This accuracy is necessary for exposure of single inhomogeneity presence: "small" ( it's square is equal 3% of global phantom square), "middle" 08,5%) and "big" (19,59%) with different surface conductivity values of these inhomogeneities (background is phantom with surface conductivity s=1). Measuring was imitated by homogeneous phantom and phantoms with inhomogeneities voltage calculating and voltage difference computing (increment) between homogeneous phantom and phantoms with inhomogeneities. Inhomogeneities with bigger surface conductivity value than background conductivity value give significantly less voltage increments than inhomogeneities with smaller surface conductivity value than background. More sensitivity with closer position to phantom outline and bigger inhomogeneities size is illustrated by means of numerous increments values. Necessary measuring accuracy numerical assessments are proposed for considered inhomogeneities.
引用
收藏
页码:92 / 104
页数:13
相关论文
共 50 条
  • [31] Electrical impedance tomography in epilepsy
    Holder, D
    ELECTRONIC ENGINEERING, 1998, 70 (859): : 69 - 70
  • [32] Multiscale electrical impedance tomography
    Pessel, M
    Gibert, D
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2003, 108 (B1)
  • [33] Wideband electrical impedance tomography
    Nahvi, M.
    Hoyle, B. S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (09)
  • [34] Electrical impedance tomography - Preface
    Barber, DC
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 : U5 - U5
  • [35] Chest electrical impedance tomography
    Grigoriadis, K.
    Armaganidis, A.
    ARCHIVES OF HELLENIC MEDICINE, 2019, 36 (05): : 589 - 596
  • [36] Implementation of electrical impedance tomography
    Levin, A. I.
    Pecherskaya, E. A.
    Varenik, Yu. A.
    Shepeleva, J. V.
    ST PETERSBURG POLYTECHNIC UNIVERSITY JOURNAL-PHYSICS AND MATHEMATICS, 2023, 16 (03): : 288 - 293
  • [37] A phantom for electrical impedance tomography
    Griffiths, H.
    Clinical Physics and Physiological Measurement, 1988, 9 (SUPPL. A): : 15 - 20
  • [38] An electrical impedance tomography microscope
    Griffiths, H.
    Tucker, M.G.
    Sage, J.
    Herrenden-Harker, W.G.
    1996, Institute of Physics Publishing (17)
  • [39] An electrical impedance tomography microscope
    Griffiths, H
    Tucker, MG
    Sage, J
    HerrendenHarker, WG
    PHYSIOLOGICAL MEASUREMENT, 1996, 17 : A15 - A24
  • [40] Rotational electrical impedance tomography
    Huang, Cheng-Ning
    Yu, Fang-Ming
    Chung, Hung-Yuan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (09) : 2958 - 2966