Evaluation of positional accuracy in multiple implants using four different splinting materials: An in vitro study

被引:5
|
作者
Joseph, Thara Maria [1 ]
Ravichandran, R. [1 ]
Lylajam, S. [1 ]
Viswabharan, Prasanth [1 ]
Janardhanan, Kavitha [1 ]
Rajeev, Smitha [1 ]
机构
[1] Govt Dent Coll, Dept Prosthodont, Trivandrum, Kerala, India
来源
关键词
Accuracy; acrylic resin; bite registration; dental implants; flowable composite; pattern resin;
D O I
10.4103/jips.jips_27_18
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: Prosthesis misfit plays an important role in complications such as occlusal and abutment screw loosening and fracture in implant restorations. Reproducing the intraoral relationship of implants through impression procedures is the first step in achieving an accurate, passively fitting prosthesis to ensure maximum accuracy. Hence, splinting of multiple implants with most accurate material may be a valid option. Context: The results of splinting multiple implants are always inconsistent, and there is limited literature available to compare the accuracy of impression techniques as well as materials. In such situation, more and more studies have to be done to prove the efficacy and accuracy of each splinting materials. Aim: The aim of the study was to evaluate the positional accuracy in multiple implants using acrylic resin, pattern resin, flowable composite, and bite registration paste. Subjects and Methods: An acrylic resin model was fabricated into which four implant analogs placed. The copings attached were splinted with dental floss onto which acrylic resin was added, which was sectioned and rewelded (Group A). Similarly, pattern resin, flowable composite, and bite registration material were added which were considered as Group B, C, and D, respectively. Impressions were made in vinyl polysiloxane and analogs were attached. The casts retrieved from each group were analysed for the positional accuracy of implants. Statistical Analysis: One-way ANOVA was done to analyze the significant difference between the four implant analogs of each group with the master model. The confidence interval was also calculated to assess the accuracy. Results: It was observed that all materials are equally effective for the accurate reproduction of implant positions. There was no significant difference between the centroids of implant analogues of master model and the mean of interimplant distance 1 and 2, 1 and 4, 3 and 4 and 2 and 4 in each group. The P-values were > 0.05. The accuracy of splinting materials were analysed and it showed that splinting with flowable composite (Group C) as well as bite registration paste were in par with the conventionally used materials like pattern resin and acrylic resin. Conclusions: Results showed that flowable composite as well as bite registration material can be recommended as splinting material of choice for multiple implant cases, as these exhibited similar results like other groups (pattern resin and acrylic resin) which are conventionally used.
引用
收藏
页码:239 / 247
页数:9
相关论文
共 50 条
  • [31] An In Vitro Study on the Accuracy of a Splint for the Transfer of Dental Implants
    Galindo, Rommy Chalacan
    Tipantuna, Angel Tul
    Araque, Maria Flores
    Poussin, Lupe
    Ron, Byron Velasquez
    PROSTHESIS, 2024, 6 (06): : 1575 - 1585
  • [32] Digital evaluation of the accuracy of impression techniques and materials in angulated implants
    Kurtulmus-Yilmaz, Sevcan
    Ozan, Oguz
    Ozcelik, Tuncer Burak
    Yagiz, Ayberk
    JOURNAL OF DENTISTRY, 2014, 42 (12) : 1551 - 1559
  • [33] Evaluation of the accuracy of digital impressions with different scanning strategies: An in vitro study
    Ortensi, Luca
    La Rosa, Giusy Rita Maria
    Ciletta, Stefania
    Granded, Francesco
    Pedulla, Eugenio
    JOURNAL OF DENTISTRY, 2024, 151
  • [34] Accuracy of four electronic apex locators:: an in vitro evaluation
    De Moor, RJG
    Hommez, GMG
    Martens, LC
    De Boever, JG
    ENDODONTICS & DENTAL TRAUMATOLOGY, 1999, 15 (02): : 77 - 82
  • [35] Comparison and Evaluation of Linear Dimensional Accuracy of Three Elastomeric Impression Materials at Different Time Intervals Using Vision Inspection System: An In Vitro Study
    Khan, Shabab Ahmed
    Tushar
    Nezam, Sumaiya
    Singh, Puja
    Kumari, Neelu
    Singh, Shashank Shekher
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2020, 10 (06): : 736 - 742
  • [36] Comparative evaluation of microleakage of four restorative materials using confocal laser scanning microscopy: an in vitro study
    Kini, Annapoorna
    Kavana, M. G.
    Shubhashini, N.
    Shetty, Nithin
    Venkataiah, Venkata Suresh
    Fareed, Mohammad
    Karobari, Mohmed Isaqali
    IRISH JOURNAL OF MEDICAL SCIENCE, 2025,
  • [37] A comparative in vitro study of different composite materials in terms of aligner attachment accuracy and surface roughness using different curing irradiances
    Erbas, Servet
    Atik, Ezgi
    INTERNATIONAL ORTHODONTICS, 2025, 23 (02)
  • [38] Comparative Evaluation of the Dimensional Accuracy of Closed Tray and Open Tray Impression Technique for Dental Implants using Two Different Impression Materials
    Tandon, Arpita
    Bulbule, Nilesh S.
    Jagtap, Amit K.
    Kakade, Dilip M.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (11) : ZC34 - ZC38
  • [39] SEM Analysis and Micro-CT Evaluation of Four Dental Implants after Three Different Mechanical Requests-In Vitro Study
    Vinhas, Ana Sofia
    Salazar, Filomena
    Mendes, Jose Manuel
    Silva, Antonio Sergio
    Rios-Carrasco, Blanca
    Rios-Santos, Jose Vicente
    Gil, Javier
    Herrero-Climent, Mariano
    Aroso, Carlos
    MATERIALS, 2024, 17 (02)
  • [40] Evaluation of the Loss of Surface Roughness Following the Use of Four Different Instruments for Mechanical Debridement of Dental Implants: An In-vitro Pilot Study
    Kumar S.
    Yewale M.
    Parthasarathi N.L.
    Balasundaram R.
    Gopalkrishna P.
    Bhat S.G.
    Journal of Bio- and Tribo-Corrosion, 2024, 10 (4)