CSI(TL)-PHOTODIODE DETECTORS FOR SPECTROSCOPY AT LOW RADIATION-LEVELS

被引:14
|
作者
KOTTHAUS, R
机构
[1] Max-Planck-Institut für Physik, Werner-Heisenberg-Institut, Munich
关键词
D O I
10.1016/0168-9002(93)91278-U
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Some aspects of CsI(Tl)-photodiode detectors relevant for applications in low level radiation spectroscopy in the MeV energy range have been studied with a view to a sensitive search for the lepton number violating neutrinoless double beta decay of Mo-100. Energy resolutions of slightly less than 100 keV (FWHM), limited by electronic noise, have been obtained for crystal masses up to more than 3 kg. The improved energy resolution facilitates a very sensitive investigation of crystal contaminations with nuclides of the Th and U chains by spectroscopic analysis of alpha-decays. The cleanest crystal was free of U and Th contaminations at the detection limit of 0.27 alpha-decays per kg and h, a radiopurity well sufficient for applications in low level spectroscopy.
引用
收藏
页码:433 / 439
页数:7
相关论文
共 50 条
  • [41] Investigation of the Screen Optics of Thick CsI(Tl) Detectors
    Howansky, Adrian
    Peng, Boyu
    Suzuki, Katsuhiko
    Yamashita, Masanori
    Lubinsky, A. R.
    Zhao, Wei
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [42] MUTAGENESIS AND RADIATION-LEVELS IN POPULATION HABITATS
    DUBININ, NP
    KALCHENKO, VA
    IZVESTIYA AKADEMII NAUK SSSR SERIYA BIOLOGICHESKAYA, 1984, (05): : 645 - 655
  • [43] FRENCH SUSPECT INFORMATION ON RADIATION-LEVELS
    COLES, P
    NATURE, 1987, 329 (6139) : 475 - 475
  • [44] NEW MONITORS CHECK RADIATION-LEVELS
    不详
    NEW SCIENTIST, 1986, 109 (1495) : 30 - 30
  • [45] RADIATION-LEVELS IN EASTERN-EUROPE
    WEBB, GAM
    SIMMONDS, JR
    WILKINS, BT
    NATURE, 1986, 321 (6073) : 821 - 822
  • [46] A New Columnar CsI(Tl) Scintillator for iQID detectors
    Han, Ling
    Miller, Brian W.
    Barber, H. Bradford
    Nagarkar, Vivek V.
    Furenlid, Lars R.
    MEDICAL APPLICATIONS OF RADIATION DETECTORS IV, 2014, 9214
  • [47] Search for solar axions with CsI(Tl) crystal detectors
    Yoon, Y. S.
    Park, H. K.
    Bhang, H.
    Choi, J. H.
    Choi, S.
    Hahn, I. S.
    Jeon, E. J.
    Joo, H. W.
    Kang, W. G.
    Kim, B. H.
    Kim, G. B.
    Kim, H. J.
    Kim, K. W.
    Kim, S. C.
    Kim, S. K.
    Kim, Y. D.
    Kim, Y. H.
    Lee, H. S.
    Lee, J. H.
    Lee, J. K.
    Leonard, D. S.
    Li, J.
    Myung, S. S.
    Olsen, S. L.
    So, J. H.
    JOURNAL OF HIGH ENERGY PHYSICS, 2016, (06): : 1 - 10
  • [48] RADIATION-LEVELS OF MACRORADIOGRAPHY - RADIATION EXPOSURE AND IMAGE QUALITY
    TAKAHASH.S
    SAKUMA, S
    AYAKAWA, Y
    MAEKOSHI, H
    OHARA, K
    RADIOLOGY, 1974, 112 (03) : 709 - 713
  • [49] RADIATION-LEVELS ASSOCIATED WITH ADVANCED LITHOGRAPHIC TECHNIQUES
    GALLOWAY, KF
    MAYO, S
    ROITMAN, P
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1979, 126 (12) : 2245 - 2248
  • [50] OPTIMISATION ON THE TWO-LAYER STACK GAMMA DETECTORS OF CSI(TL) COUPLED WITH A PIN PHOTODIODE FOR NON-DESTRUCTIVE TESTING
    Bai, Jin Hyoung
    Whang, Joo Ho
    RADIATION PROTECTION DOSIMETRY, 2011, 146 (1-3) : 76 - 79